test on optional offset for mqtt sensor (#139)

This commit is contained in:
avollkopf 2024-07-06 09:06:48 +02:00
parent 62370980e0
commit c58ca46219
5 changed files with 169 additions and 14 deletions

View file

@ -1,3 +1,3 @@
__version__ = "4.4.3.a2"
__version__ = "4.4.3.a3"
__codename__ = "Yeast Starter"

View file

@ -7,7 +7,12 @@ from cbpi.configFolder import ConfigFolder
from cbpi.utils.utils import load_config
from zipfile import ZipFile
from cbpi.craftbeerpi import CraftBeerPi
import os, pwd
import os
try:
import pwd
module_pwd=True
except:
module_pwd=False
import pkgutil
import shutil
import click

View file

@ -11,6 +11,7 @@ mqtt_host: localhost
mqtt_port: 1883
mqtt_username: ""
mqtt_password: ""
mqtt_offset: false
username: cbpi
password: 123

View file

@ -8,7 +8,7 @@ import json
from cbpi.api import *
from cbpi.api.config import ConfigType
from cbpi.api.base import CBPiBase
import glob
import glob, yaml
from cbpi import __version__
logger = logging.getLogger(__name__)
@ -19,6 +19,12 @@ class ConfigUpdate(CBPiExtension):
self.cbpi = cbpi
self._task = asyncio.create_task(self.run())
def append_to_yaml(self, file_path, data_to_append):
with open(file_path[0], 'a+') as file:
file.seek(0)
yaml.dump(data_to_append, file, default_flow_style=False)
async def run(self):
logging.info("Check Config for required changes")
@ -67,7 +73,7 @@ class ConfigUpdate(CBPiExtension):
CONFIG_STATUS = self.cbpi.config.get("CONFIG_STATUS", None)
self.version=__version__
current_grid = self.cbpi.config.get("current_grid", None)
mqtt_offset=self.cbpi.static_config.get("mqtt_offset", None)
if boil_temp is None:
logger.info("INIT Boil Temp Setting")
@ -558,6 +564,16 @@ class ConfigUpdate(CBPiExtension):
except Exception as e:
logging.error(e)
if mqtt_offset is None:
logging.info("INIT MQTT Offset in static config")
try:
static_config_file=glob.glob(self.cbpi.config_folder.get_file_path('config.yaml'))
data_to_append = {'mqtt_offset': False}
self.append_to_yaml(static_config_file, data_to_append)
pass
except Exception as e:
logging.error(e)
logging.warning('Unable to update database')
## Check if influxdbname is in config
if CONFIG_STATUS is None or CONFIG_STATUS != self.version:

View file

@ -8,16 +8,17 @@ import json
import time
from datetime import datetime
@parameters([Property.Text(label="Topic", configurable=True, description="MQTT Topic"),
Property.Text(label="PayloadDictionary", configurable=True, default_value="",
description="Where to find msg in payload, leave blank for raw payload"),
Property.Kettle(label="Kettle", description="Reduced logging if Kettle is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
Property.Fermenter(label="Fermenter", description="Reduced logging if Fermenter is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
Property.Number(label="ReducedLogging", configurable=True, description="Reduced logging frequency in seconds if selected Kettle or Fermenter is inactive (default:60 sec | 0 disabled)"),
Property.Number(label="Timeout", configurable=True, unit="sec",
description="Timeout in seconds to send notification (default:60 | deactivated: 0)"),
Property.Number(label="TempRange", configurable=True, unit="degree",
description="Temp range in degree between reading and target temp of fermenter/kettle. Larger difference shows different color in dashboard (default:0 | deactivated: 0)")])
Property.Text(label="PayloadDictionary", configurable=True, default_value="",
description="Where to find msg in payload, leave blank for raw payload"),
Property.Kettle(label="Kettle", description="Reduced logging if Kettle is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
Property.Fermenter(label="Fermenter", description="Reduced logging if Fermenter is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
Property.Number(label="ReducedLogging", configurable=True, description="Reduced logging frequency in seconds if selected Kettle or Fermenter is inactive (default:60 sec | 0 disabled)"),
Property.Number(label="Timeout", configurable=True, unit="sec",
description="Timeout in seconds to send notification (default:60 | deactivated: 0)"),
Property.Number(label="TempRange", configurable=True, unit="degree",
description="Temp range in degree between reading and target temp of fermenter/kettle. Larger difference shows different color in dashboard (default:0 | deactivated: 0)")])
class MQTTSensor(CBPiSensor):
def __init__(self, cbpi, id, props):
@ -135,6 +136,135 @@ class MQTTSensor(CBPiSensor):
async def on_stop(self):
self.subscribed = self.cbpi.satellite.unsubscribe(self.Topic, self.on_message)
@parameters([Property.Text(label="Topic", configurable=True, description="MQTT Topic"),
Property.Text(label="PayloadDictionary", configurable=True, default_value="",
description="Where to find msg in payload, leave blank for raw payload"),
Property.Kettle(label="Kettle", description="Reduced logging if Kettle is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
Property.Fermenter(label="Fermenter", description="Reduced logging if Fermenter is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
Property.Number(label="Offset", configurable=True, description="Offset for MQTT Sensor (default is 0). !!! Use this only with caution as offset for MQTT sensor should be defined on Sensor side !!!"),
Property.Number(label="ReducedLogging", configurable=True, description="Reduced logging frequency in seconds if selected Kettle or Fermenter is inactive (default:60 sec | 0 disabled)"),
Property.Number(label="Timeout", configurable=True, unit="sec",
description="Timeout in seconds to send notification (default:60 | deactivated: 0)"),
Property.Number(label="TempRange", configurable=True, unit="degree",
description="Temp range in degree between reading and target temp of fermenter/kettle. Larger difference shows different color in dashboard (default:0 | deactivated: 0)")])
class MQTTSensorOffset(CBPiSensor):
def __init__(self, cbpi, id, props):
super(MQTTSensorOffset, self).__init__(cbpi, id, props)
self.Topic = self.props.get("Topic", None)
self.offset = float(self.props.get("Offset", 0))
self.payload_text = self.props.get("PayloadDictionary", None)
if self.payload_text != None:
self.payload_text = self.payload_text.split('.')
self.subscribed = self.cbpi.satellite.subscribe(self.Topic, self.on_message)
self.value: float = 999
self.timeout=int(self.props.get("Timeout", 60))
self.temprange=float(self.props.get("TempRange", 0))
self.starttime = time.time()
self.notificationsend = False
self.nextchecktime=self.starttime+self.timeout
self.lastdata=time.time()
self.lastlog=0
self.sensor=self.get_sensor(self.id)
self.reducedfrequency=int(self.props.get("ReducedLogging", 60))
if self.reducedfrequency < 0:
self.reducedfrequency = 0
self.kettleid=self.props.get("Kettle", None)
self.fermenterid=self.props.get("Fermenter", None)
self.reducedlogging = True if self.kettleid or self.fermenterid else False
if self.kettleid is not None and self.fermenterid is not None:
self.reducedlogging=False
self.cbpi.notify("MQTTSensor", "Sensor '" + str(self.sensor.name) + "' cant't have Fermenter and Kettle defined for reduced logging / range warning.", NotificationType.WARNING, action=[NotificationAction("OK", self.Confirm)])
async def Confirm(self, **kwargs):
self.nextchecktime = time.time() + self.timeout
self.notificationsend = False
pass
async def message(self):
target_timestring= datetime.fromtimestamp(self.lastdata)
self.cbpi.notify("MQTTSensor Timeout", "Sensor '" + str(self.sensor.name) + "' did not respond. Last data received: "+target_timestring.strftime("%D %H:%M"), NotificationType.WARNING, action=[NotificationAction("OK", self.Confirm)])
pass
async def on_message(self, message):
val = json.loads(message.payload.decode())
try:
if self.payload_text is not None:
for key in self.payload_text:
val = val.get(key, None)
if isinstance(val, (int, float, str)):
self.value = float(val)+self.offset
self.push_update(self.value)
if self.reducedlogging == True:
await self.logvalue()
else:
logging.info("MQTTSensor {} regular logging".format(self.sensor.name))
self.log_data(self.value)
self.lastlog = time.time()
if self.timeout !=0:
self.nextchecktime = time.time() + self.timeout
self.notificationsend = False
self.lastdata=time.time()
except Exception as e:
logging.error("MQTT Sensor Error {}".format(e))
async def logvalue(self):
self.kettle = self.get_kettle(self.kettleid) if self.kettleid is not None else None
self.fermenter = self.get_fermenter(self.fermenterid) if self.fermenterid is not None else None
now=time.time()
if self.kettle is not None:
try:
kettlestatus=self.kettle.instance.state
except:
kettlestatus=False
if kettlestatus:
self.log_data(self.value)
logging.info("MQTTSensor {} Kettle Active".format(self.sensor.name))
self.lastlog = time.time()
else:
logging.info("MQTTSensor {} Kettle Inactive".format(self.sensor.name))
if self.reducedfrequency != 0:
if now >= self.lastlog + self.reducedfrequency:
self.log_data(self.value)
self.lastlog = time.time()
logging.info("Logged with reduced freqency")
pass
if self.fermenter is not None:
try:
fermenterstatus=self.fermenter.instance.state
except:
fermenterstatus=False
if fermenterstatus:
self.log_data(self.value)
logging.info("MQTTSensor {} Fermenter Active".format(self.sensor.name))
self.lastlog = time.time()
else:
logging.info("MQTTSensor {} Fermenter Inactive".format(self.sensor.name))
if self.reducedfrequency != 0:
if now >= self.lastlog + self.reducedfrequency:
self.log_data(self.value)
self.lastlog = time.time()
logging.info("Logged with reduced freqency")
pass
async def run(self):
while self.running:
if self.timeout !=0:
if time.time() > self.nextchecktime and self.notificationsend == False:
await self.message()
self.notificationsend=True
await asyncio.sleep(1)
def get_state(self):
return dict(value=self.value)
async def on_stop(self):
self.subscribed = self.cbpi.satellite.unsubscribe(self.Topic, self.on_message)
def setup(cbpi):
'''
@ -145,4 +275,7 @@ def setup(cbpi):
:return:
'''
if str(cbpi.static_config.get("mqtt", False)).lower() == "true":
cbpi.plugin.register("MQTTSensor", MQTTSensor)
if str(cbpi.static_config.get("mqtt_offset", False)).lower() == "false":
cbpi.plugin.register("MQTTSensor", MQTTSensor)
else:
cbpi.plugin.register("MQTTSensor", MQTTSensorOffset)