mirror of
https://github.com/PiBrewing/craftbeerpi4.git
synced 2024-11-21 14:38:15 +01:00
test on optional offset for mqtt sensor (#139)
This commit is contained in:
parent
62370980e0
commit
c58ca46219
5 changed files with 169 additions and 14 deletions
|
@ -1,3 +1,3 @@
|
|||
__version__ = "4.4.3.a2"
|
||||
__version__ = "4.4.3.a3"
|
||||
__codename__ = "Yeast Starter"
|
||||
|
||||
|
|
|
@ -7,7 +7,12 @@ from cbpi.configFolder import ConfigFolder
|
|||
from cbpi.utils.utils import load_config
|
||||
from zipfile import ZipFile
|
||||
from cbpi.craftbeerpi import CraftBeerPi
|
||||
import os, pwd
|
||||
import os
|
||||
try:
|
||||
import pwd
|
||||
module_pwd=True
|
||||
except:
|
||||
module_pwd=False
|
||||
import pkgutil
|
||||
import shutil
|
||||
import click
|
||||
|
|
|
@ -11,6 +11,7 @@ mqtt_host: localhost
|
|||
mqtt_port: 1883
|
||||
mqtt_username: ""
|
||||
mqtt_password: ""
|
||||
mqtt_offset: false
|
||||
|
||||
username: cbpi
|
||||
password: 123
|
||||
|
|
|
@ -8,7 +8,7 @@ import json
|
|||
from cbpi.api import *
|
||||
from cbpi.api.config import ConfigType
|
||||
from cbpi.api.base import CBPiBase
|
||||
import glob
|
||||
import glob, yaml
|
||||
from cbpi import __version__
|
||||
|
||||
logger = logging.getLogger(__name__)
|
||||
|
@ -19,6 +19,12 @@ class ConfigUpdate(CBPiExtension):
|
|||
self.cbpi = cbpi
|
||||
self._task = asyncio.create_task(self.run())
|
||||
|
||||
def append_to_yaml(self, file_path, data_to_append):
|
||||
|
||||
with open(file_path[0], 'a+') as file:
|
||||
file.seek(0)
|
||||
yaml.dump(data_to_append, file, default_flow_style=False)
|
||||
|
||||
|
||||
async def run(self):
|
||||
logging.info("Check Config for required changes")
|
||||
|
@ -67,7 +73,7 @@ class ConfigUpdate(CBPiExtension):
|
|||
CONFIG_STATUS = self.cbpi.config.get("CONFIG_STATUS", None)
|
||||
self.version=__version__
|
||||
current_grid = self.cbpi.config.get("current_grid", None)
|
||||
|
||||
mqtt_offset=self.cbpi.static_config.get("mqtt_offset", None)
|
||||
|
||||
if boil_temp is None:
|
||||
logger.info("INIT Boil Temp Setting")
|
||||
|
@ -558,6 +564,16 @@ class ConfigUpdate(CBPiExtension):
|
|||
except Exception as e:
|
||||
logging.error(e)
|
||||
|
||||
if mqtt_offset is None:
|
||||
logging.info("INIT MQTT Offset in static config")
|
||||
try:
|
||||
static_config_file=glob.glob(self.cbpi.config_folder.get_file_path('config.yaml'))
|
||||
data_to_append = {'mqtt_offset': False}
|
||||
self.append_to_yaml(static_config_file, data_to_append)
|
||||
pass
|
||||
except Exception as e:
|
||||
logging.error(e)
|
||||
logging.warning('Unable to update database')
|
||||
|
||||
## Check if influxdbname is in config
|
||||
if CONFIG_STATUS is None or CONFIG_STATUS != self.version:
|
||||
|
|
|
@ -8,16 +8,17 @@ import json
|
|||
import time
|
||||
from datetime import datetime
|
||||
|
||||
|
||||
@parameters([Property.Text(label="Topic", configurable=True, description="MQTT Topic"),
|
||||
Property.Text(label="PayloadDictionary", configurable=True, default_value="",
|
||||
description="Where to find msg in payload, leave blank for raw payload"),
|
||||
Property.Kettle(label="Kettle", description="Reduced logging if Kettle is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
|
||||
Property.Fermenter(label="Fermenter", description="Reduced logging if Fermenter is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
|
||||
Property.Number(label="ReducedLogging", configurable=True, description="Reduced logging frequency in seconds if selected Kettle or Fermenter is inactive (default:60 sec | 0 disabled)"),
|
||||
Property.Number(label="Timeout", configurable=True, unit="sec",
|
||||
description="Timeout in seconds to send notification (default:60 | deactivated: 0)"),
|
||||
Property.Number(label="TempRange", configurable=True, unit="degree",
|
||||
description="Temp range in degree between reading and target temp of fermenter/kettle. Larger difference shows different color in dashboard (default:0 | deactivated: 0)")])
|
||||
Property.Text(label="PayloadDictionary", configurable=True, default_value="",
|
||||
description="Where to find msg in payload, leave blank for raw payload"),
|
||||
Property.Kettle(label="Kettle", description="Reduced logging if Kettle is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
|
||||
Property.Fermenter(label="Fermenter", description="Reduced logging if Fermenter is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
|
||||
Property.Number(label="ReducedLogging", configurable=True, description="Reduced logging frequency in seconds if selected Kettle or Fermenter is inactive (default:60 sec | 0 disabled)"),
|
||||
Property.Number(label="Timeout", configurable=True, unit="sec",
|
||||
description="Timeout in seconds to send notification (default:60 | deactivated: 0)"),
|
||||
Property.Number(label="TempRange", configurable=True, unit="degree",
|
||||
description="Temp range in degree between reading and target temp of fermenter/kettle. Larger difference shows different color in dashboard (default:0 | deactivated: 0)")])
|
||||
class MQTTSensor(CBPiSensor):
|
||||
|
||||
def __init__(self, cbpi, id, props):
|
||||
|
@ -135,6 +136,135 @@ class MQTTSensor(CBPiSensor):
|
|||
async def on_stop(self):
|
||||
self.subscribed = self.cbpi.satellite.unsubscribe(self.Topic, self.on_message)
|
||||
|
||||
@parameters([Property.Text(label="Topic", configurable=True, description="MQTT Topic"),
|
||||
Property.Text(label="PayloadDictionary", configurable=True, default_value="",
|
||||
description="Where to find msg in payload, leave blank for raw payload"),
|
||||
Property.Kettle(label="Kettle", description="Reduced logging if Kettle is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
|
||||
Property.Fermenter(label="Fermenter", description="Reduced logging if Fermenter is inactive / range warning in dashboard (only Kettle or Fermenter to be selected)"),
|
||||
Property.Number(label="Offset", configurable=True, description="Offset for MQTT Sensor (default is 0). !!! Use this only with caution as offset for MQTT sensor should be defined on Sensor side !!!"),
|
||||
Property.Number(label="ReducedLogging", configurable=True, description="Reduced logging frequency in seconds if selected Kettle or Fermenter is inactive (default:60 sec | 0 disabled)"),
|
||||
Property.Number(label="Timeout", configurable=True, unit="sec",
|
||||
description="Timeout in seconds to send notification (default:60 | deactivated: 0)"),
|
||||
Property.Number(label="TempRange", configurable=True, unit="degree",
|
||||
description="Temp range in degree between reading and target temp of fermenter/kettle. Larger difference shows different color in dashboard (default:0 | deactivated: 0)")])
|
||||
class MQTTSensorOffset(CBPiSensor):
|
||||
|
||||
def __init__(self, cbpi, id, props):
|
||||
super(MQTTSensorOffset, self).__init__(cbpi, id, props)
|
||||
self.Topic = self.props.get("Topic", None)
|
||||
self.offset = float(self.props.get("Offset", 0))
|
||||
self.payload_text = self.props.get("PayloadDictionary", None)
|
||||
if self.payload_text != None:
|
||||
self.payload_text = self.payload_text.split('.')
|
||||
self.subscribed = self.cbpi.satellite.subscribe(self.Topic, self.on_message)
|
||||
self.value: float = 999
|
||||
self.timeout=int(self.props.get("Timeout", 60))
|
||||
self.temprange=float(self.props.get("TempRange", 0))
|
||||
self.starttime = time.time()
|
||||
self.notificationsend = False
|
||||
self.nextchecktime=self.starttime+self.timeout
|
||||
self.lastdata=time.time()
|
||||
self.lastlog=0
|
||||
self.sensor=self.get_sensor(self.id)
|
||||
self.reducedfrequency=int(self.props.get("ReducedLogging", 60))
|
||||
if self.reducedfrequency < 0:
|
||||
self.reducedfrequency = 0
|
||||
self.kettleid=self.props.get("Kettle", None)
|
||||
self.fermenterid=self.props.get("Fermenter", None)
|
||||
self.reducedlogging = True if self.kettleid or self.fermenterid else False
|
||||
|
||||
if self.kettleid is not None and self.fermenterid is not None:
|
||||
self.reducedlogging=False
|
||||
self.cbpi.notify("MQTTSensor", "Sensor '" + str(self.sensor.name) + "' cant't have Fermenter and Kettle defined for reduced logging / range warning.", NotificationType.WARNING, action=[NotificationAction("OK", self.Confirm)])
|
||||
|
||||
async def Confirm(self, **kwargs):
|
||||
self.nextchecktime = time.time() + self.timeout
|
||||
self.notificationsend = False
|
||||
pass
|
||||
|
||||
async def message(self):
|
||||
target_timestring= datetime.fromtimestamp(self.lastdata)
|
||||
self.cbpi.notify("MQTTSensor Timeout", "Sensor '" + str(self.sensor.name) + "' did not respond. Last data received: "+target_timestring.strftime("%D %H:%M"), NotificationType.WARNING, action=[NotificationAction("OK", self.Confirm)])
|
||||
pass
|
||||
|
||||
async def on_message(self, message):
|
||||
val = json.loads(message.payload.decode())
|
||||
try:
|
||||
if self.payload_text is not None:
|
||||
for key in self.payload_text:
|
||||
val = val.get(key, None)
|
||||
|
||||
if isinstance(val, (int, float, str)):
|
||||
self.value = float(val)+self.offset
|
||||
self.push_update(self.value)
|
||||
if self.reducedlogging == True:
|
||||
await self.logvalue()
|
||||
else:
|
||||
logging.info("MQTTSensor {} regular logging".format(self.sensor.name))
|
||||
self.log_data(self.value)
|
||||
self.lastlog = time.time()
|
||||
|
||||
if self.timeout !=0:
|
||||
self.nextchecktime = time.time() + self.timeout
|
||||
self.notificationsend = False
|
||||
self.lastdata=time.time()
|
||||
except Exception as e:
|
||||
logging.error("MQTT Sensor Error {}".format(e))
|
||||
|
||||
async def logvalue(self):
|
||||
self.kettle = self.get_kettle(self.kettleid) if self.kettleid is not None else None
|
||||
self.fermenter = self.get_fermenter(self.fermenterid) if self.fermenterid is not None else None
|
||||
now=time.time()
|
||||
if self.kettle is not None:
|
||||
try:
|
||||
kettlestatus=self.kettle.instance.state
|
||||
except:
|
||||
kettlestatus=False
|
||||
if kettlestatus:
|
||||
self.log_data(self.value)
|
||||
logging.info("MQTTSensor {} Kettle Active".format(self.sensor.name))
|
||||
self.lastlog = time.time()
|
||||
else:
|
||||
logging.info("MQTTSensor {} Kettle Inactive".format(self.sensor.name))
|
||||
if self.reducedfrequency != 0:
|
||||
if now >= self.lastlog + self.reducedfrequency:
|
||||
self.log_data(self.value)
|
||||
self.lastlog = time.time()
|
||||
logging.info("Logged with reduced freqency")
|
||||
pass
|
||||
|
||||
if self.fermenter is not None:
|
||||
try:
|
||||
fermenterstatus=self.fermenter.instance.state
|
||||
except:
|
||||
fermenterstatus=False
|
||||
if fermenterstatus:
|
||||
self.log_data(self.value)
|
||||
logging.info("MQTTSensor {} Fermenter Active".format(self.sensor.name))
|
||||
self.lastlog = time.time()
|
||||
else:
|
||||
logging.info("MQTTSensor {} Fermenter Inactive".format(self.sensor.name))
|
||||
if self.reducedfrequency != 0:
|
||||
if now >= self.lastlog + self.reducedfrequency:
|
||||
self.log_data(self.value)
|
||||
self.lastlog = time.time()
|
||||
logging.info("Logged with reduced freqency")
|
||||
pass
|
||||
|
||||
async def run(self):
|
||||
while self.running:
|
||||
if self.timeout !=0:
|
||||
if time.time() > self.nextchecktime and self.notificationsend == False:
|
||||
await self.message()
|
||||
self.notificationsend=True
|
||||
await asyncio.sleep(1)
|
||||
|
||||
def get_state(self):
|
||||
return dict(value=self.value)
|
||||
|
||||
async def on_stop(self):
|
||||
self.subscribed = self.cbpi.satellite.unsubscribe(self.Topic, self.on_message)
|
||||
|
||||
|
||||
def setup(cbpi):
|
||||
'''
|
||||
|
@ -145,4 +275,7 @@ def setup(cbpi):
|
|||
:return:
|
||||
'''
|
||||
if str(cbpi.static_config.get("mqtt", False)).lower() == "true":
|
||||
cbpi.plugin.register("MQTTSensor", MQTTSensor)
|
||||
if str(cbpi.static_config.get("mqtt_offset", False)).lower() == "false":
|
||||
cbpi.plugin.register("MQTTSensor", MQTTSensor)
|
||||
else:
|
||||
cbpi.plugin.register("MQTTSensor", MQTTSensorOffset)
|
||||
|
|
Loading…
Reference in a new issue