- forces mqtt update for kettle and femrenter in specified timeframes even w/o change in payload
- required for mqttdevice
- only active if mqtt is enabled
- can be set to never and is also deactivated when mqtt is enabled
- Different names for fermentersteps as Notificationstep caused an issue (steps not yot implemented for fermentation)
- Reverted back item based mqtt as this may require further testing -> will be activated in dev branch later
-> sensor values are updated under sensordata/{sensorid}
One topic for each sensor to keep data small (esp compatibility)
actor, kettle, sensor, fermenter, steps are updated also for each id individually to keep packets small
e.g. actorupdate/{actorid}
This was proposed by Innuendo to ensure compatibility with the ESP based MQTTDevice
Added fermenter type
Added fermenter logic (incl. new class)
-> will require cbpi4ui -> >= 0.1.a1
Still under development, but fermentation w/o steps should be working
- Actor used to set power to 100 eventhough target was 0
- moved chromium.desktop file to config folder -> easier available for users and potential to enable chromium desktop via cbpi commandline in future
RPi.GPIO 0.7.0 is causing an error if installed under bullseye and python 3.9
-> 0.7.1a4 solves the issue for now.
-> will be changed as soon as new RPi.GPIO release is comming out
Power = 100: standard on
Standard sampling time is 5 seconds.
if power is set to 50%, heating time is 2.5 sec and witing time (gpio off) is also 2.5 sec
Changing power to lower readings, wil reduce heating time within the 5 seconeds and increase waiting time
Increase of power results in longer heating times and reduced wait times
Sort of a poos men's PWM with a fix requency of 0.2 hz
This will reduce the complexity of all PID plugins.
Some additional tests and changes might be required for api.
- Up to 10 Dashboards possible
- Config parameter max_dashboard_number added
- Default is 4 dashboards
- Config parameter will be added automatically via extension if not in config.json