Change for sensor plugins.
Will update also mqtt per default when push_update is called.
But if False is send for mqtt parameter, only web interface will be updated.
-> Good for sensors that retrieve values only once per minute or so
-> WI can be continuosly updated with current value and no empty value is displayed, but mqtt does not nee to be updated
(example ispindel, scd30 sensor, kettle sensor, Hydrom/Tilt,....)
Plugins will be updated later in main branches
- Different names for fermentersteps as Notificationstep caused an issue (steps not yot implemented for fermentation)
- Reverted back item based mqtt as this may require further testing -> will be activated in dev branch later
In case of different boil kettle, sensor from first kettle was used by external recipe import. Thi sis now fixed.
In case of different boil kettle, Sensor specified for this kettle will be used during external recipe import
-> sensor values are updated under sensordata/{sensorid}
One topic for each sensor to keep data small (esp compatibility)
actor, kettle, sensor, fermenter, steps are updated also for each id individually to keep packets small
e.g. actorupdate/{actorid}
This was proposed by Innuendo to ensure compatibility with the ESP based MQTTDevice
Added fermenter type
Added fermenter logic (incl. new class)
-> will require cbpi4ui -> >= 0.1.a1
Still under development, but fermentation w/o steps should be working
- bumped Version to 4.0.0.56
- Uncommented on push_ update in basic_controller2.py which seemd to cause error messages during startup and is not required
- Actor used to set power to 100 eventhough target was 0
- moved chromium.desktop file to config folder -> easier available for users and potential to enable chromium desktop via cbpi commandline in future
RPi.GPIO 0.7.0 is causing an error if installed under bullseye and python 3.9
-> 0.7.1a4 solves the issue for now.
-> will be changed as soon as new RPi.GPIO release is comming out
Power = 100: standard on
Standard sampling time is 5 seconds.
if power is set to 50%, heating time is 2.5 sec and witing time (gpio off) is also 2.5 sec
Changing power to lower readings, wil reduce heating time within the 5 seconeds and increase waiting time
Increase of power results in longer heating times and reduced wait times
Sort of a poos men's PWM with a fix requency of 0.2 hz
This will reduce the complexity of all PID plugins.
Some additional tests and changes might be required for api.
- cbpi is now checking if a zip is existing to restore the config during start.
- If zip is there, content is checked prior to restore
- if required content is found, config folder is removed and zip is extracted.
- afterwards zip is removed
- cbpi is starting with restored config
Version -> 4.0.0.38