esphome/tests/components/opentherm/common.yaml

174 lines
5 KiB
YAML
Raw Normal View History

api:
wifi:
ap:
ssid: "Thermostat"
password: "MySecretThemostat"
opentherm:
in_pin: 4
out_pin: 5
ch_enable: true
dhw_enable: false
cooling_enable: false
otc_active: false
ch2_active: true
t_room: boiler_sensor
summer_mode_active: true
dhw_block: true
sync_mode: true
controller_product_type: 63
controller_product_version: 1
opentherm_version_controller: 2.2
controller_id: 1
controller_configuration: 1
before_send:
then:
- lambda: |-
ESP_LOGW("OT", ">> Sending message %d", x.id);
before_process_response:
then:
- lambda: |-
ESP_LOGW("OT", "<< Processing response %d", x.id);
output:
- platform: opentherm
t_set:
id: t_set
min_value: 20
auto_max_value: true
zero_means_zero: true
t_set_ch2:
id: t_set_ch2
min_value: 20
max_value: 40
zero_means_zero: true
number:
- platform: opentherm
cooling_control:
name: "Boiler Cooling control signal"
t_dhw_set:
name: "Boiler DHW Setpoint"
max_t_set:
name: "Boiler Max Setpoint"
t_room_set:
name: "Boiler Room Setpoint"
t_room_set_ch2:
name: "Boiler Room Setpoint CH2"
max_rel_mod_level:
name: "Maximum relative modulation level"
otc_hc_ratio:
name: "OTC heat curve ratio"
sensor:
- platform: opentherm
rel_mod_level:
name: "Boiler Relative modulation level"
ch_pressure:
name: "Boiler Water pressure in CH circuit"
dhw_flow_rate:
name: "Boiler Water flow rate in DHW circuit"
t_boiler:
id: "boiler_sensor"
name: "Boiler water temperature"
t_dhw:
name: "Boiler DHW temperature"
t_outside:
name: "Boiler Outside temperature"
t_ret:
name: "Boiler Return water temperature"
t_storage:
name: "Boiler Solar storage temperature"
t_collector:
name: "Boiler Solar collector temperature"
t_flow_ch2:
name: "Boiler Flow water temperature CH2 circuit"
t_dhw2:
name: "Boiler Domestic hot water temperature 2"
t_exhaust:
name: "Boiler Exhaust temperature"
burner_starts:
name: "Boiler Number of starts burner"
ch_pump_starts:
name: "Boiler Number of starts CH pump"
dhw_pump_valve_starts:
name: "Boiler Number of starts DHW pump/valve"
dhw_burner_starts:
name: "Boiler Number of starts burner during DHW mode"
burner_operation_hours:
name: "Boiler Number of hours that burner is in operation (i.e. flame on)"
ch_pump_operation_hours:
name: "Boiler Number of hours that CH pump has been running"
dhw_pump_valve_operation_hours:
name: "Boiler Number of hours that DHW pump has been running or DHW valve has been opened"
dhw_burner_operation_hours:
name: "Boiler Number of hours that burner is in operation during DHW mode"
t_dhw_set_ub:
name: "Boiler Upper bound for adjustement of DHW setpoint"
t_dhw_set_lb:
name: "Boiler Lower bound for adjustement of DHW setpoint"
max_t_set_ub:
name: "Boiler Upper bound for adjustement of max CH setpoint"
max_t_set_lb:
name: "Boiler Lower bound for adjustement of max CH setpoint"
t_dhw_set:
name: "Boiler Domestic hot water temperature setpoint"
max_t_set:
name: "Boiler Maximum allowable CH water setpoint"
otc_hc_ratio_ub:
name: "OTC heat curve ratio upper bound"
otc_hc_ratio_lb:
name: "OTC heat curve ratio lower bound"
binary_sensor:
- platform: opentherm
fault_indication:
name: "Boiler Fault indication"
ch_active:
name: "Boiler Central Heating active"
dhw_active:
name: "Boiler Domestic Hot Water active"
flame_on:
name: "Boiler Flame on"
cooling_active:
name: "Boiler Cooling active"
ch2_active:
name: "Boiler Central Heating 2 active"
diagnostic_indication:
name: "Boiler Diagnostic event"
dhw_present:
name: "Boiler DHW present"
control_type_on_off:
name: "Boiler Control type is on/off"
cooling_supported:
name: "Boiler Cooling supported"
dhw_storage_tank:
name: "Boiler DHW storage tank"
controller_pump_control_allowed:
name: "Boiler Controller pump control allowed"
ch2_present:
name: "Boiler CH2 present"
dhw_setpoint_transfer_enabled:
name: "Boiler DHW setpoint transfer enabled"
max_ch_setpoint_transfer_enabled:
name: "Boiler CH maximum setpoint transfer enabled"
dhw_setpoint_rw:
name: "Boiler DHW setpoint read/write"
max_ch_setpoint_rw:
name: "Boiler CH maximum setpoint read/write"
switch:
- platform: opentherm
ch_enable:
name: "Boiler Central Heating enabled"
restore_mode: RESTORE_DEFAULT_ON
dhw_enable:
name: "Boiler Domestic Hot Water enabled"
cooling_enable:
name: "Boiler Cooling enabled"
restore_mode: ALWAYS_OFF
otc_active:
name: "Boiler Outside temperature compensation active"
ch2_active:
name: "Boiler Central Heating 2 active"