[modbus_controller] Add on_command_sent trigger (#7078)
Co-authored-by: Leo Schelvis <leo.schelvis@gmail.com>
This commit is contained in:
parent
a464e46d4d
commit
0a7d883633
5 changed files with 57 additions and 2 deletions
|
@ -1,8 +1,16 @@
|
|||
import binascii
|
||||
import esphome.codegen as cg
|
||||
import esphome.config_validation as cv
|
||||
from esphome import automation
|
||||
from esphome.components import modbus
|
||||
from esphome.const import CONF_ADDRESS, CONF_ID, CONF_NAME, CONF_LAMBDA, CONF_OFFSET
|
||||
from esphome.const import (
|
||||
CONF_ADDRESS,
|
||||
CONF_ID,
|
||||
CONF_NAME,
|
||||
CONF_LAMBDA,
|
||||
CONF_OFFSET,
|
||||
CONF_TRIGGER_ID,
|
||||
)
|
||||
from esphome.cpp_helpers import logging
|
||||
from .const import (
|
||||
CONF_BITMASK,
|
||||
|
@ -12,6 +20,7 @@ from .const import (
|
|||
CONF_CUSTOM_COMMAND,
|
||||
CONF_FORCE_NEW_RANGE,
|
||||
CONF_MODBUS_CONTROLLER_ID,
|
||||
CONF_ON_COMMAND_SENT,
|
||||
CONF_REGISTER_COUNT,
|
||||
CONF_REGISTER_TYPE,
|
||||
CONF_RESPONSE_SIZE,
|
||||
|
@ -97,6 +106,10 @@ TYPE_REGISTER_MAP = {
|
|||
"FP32_R": 2,
|
||||
}
|
||||
|
||||
ModbusCommandSentTrigger = modbus_controller_ns.class_(
|
||||
"ModbusCommandSentTrigger", automation.Trigger.template(cg.int_, cg.int_)
|
||||
)
|
||||
|
||||
_LOGGER = logging.getLogger(__name__)
|
||||
|
||||
ModbusServerRegisterSchema = cv.Schema(
|
||||
|
@ -120,13 +133,19 @@ CONFIG_SCHEMA = cv.All(
|
|||
cv.Optional(
|
||||
CONF_SERVER_REGISTERS,
|
||||
): cv.ensure_list(ModbusServerRegisterSchema),
|
||||
cv.Optional(CONF_ON_COMMAND_SENT): automation.validate_automation(
|
||||
{
|
||||
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(
|
||||
ModbusCommandSentTrigger
|
||||
),
|
||||
}
|
||||
),
|
||||
}
|
||||
)
|
||||
.extend(cv.polling_component_schema("60s"))
|
||||
.extend(modbus.modbus_device_schema(0x01))
|
||||
)
|
||||
|
||||
|
||||
ModbusItemBaseSchema = cv.Schema(
|
||||
{
|
||||
cv.GenerateID(CONF_MODBUS_CONTROLLER_ID): cv.use_id(ModbusController),
|
||||
|
@ -254,6 +273,11 @@ async def to_code(config):
|
|||
)
|
||||
)
|
||||
await register_modbus_device(var, config)
|
||||
for conf in config.get(CONF_ON_COMMAND_SENT, []):
|
||||
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
|
||||
await automation.build_automation(
|
||||
trigger, [(int, "function_code"), (int, "address")], conf
|
||||
)
|
||||
|
||||
|
||||
async def register_modbus_device(var, config):
|
||||
|
|
19
esphome/components/modbus_controller/automation.h
Normal file
19
esphome/components/modbus_controller/automation.h
Normal file
|
@ -0,0 +1,19 @@
|
|||
#pragma once
|
||||
|
||||
#include "esphome/core/component.h"
|
||||
#include "esphome/core/automation.h"
|
||||
#include "esphome/components/modbus_controller/modbus_controller.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace modbus_controller {
|
||||
|
||||
class ModbusCommandSentTrigger : public Trigger<int, int> {
|
||||
public:
|
||||
ModbusCommandSentTrigger(ModbusController *a_modbuscontroller) {
|
||||
a_modbuscontroller->add_on_command_sent_callback(
|
||||
[this](int function_code, int address) { this->trigger(function_code, address); });
|
||||
}
|
||||
};
|
||||
|
||||
} // namespace modbus_controller
|
||||
} // namespace esphome
|
|
@ -6,6 +6,7 @@ CONF_CUSTOM_COMMAND = "custom_command"
|
|||
CONF_FORCE_NEW_RANGE = "force_new_range"
|
||||
CONF_MODBUS_CONTROLLER_ID = "modbus_controller_id"
|
||||
CONF_MODBUS_FUNCTIONCODE = "modbus_functioncode"
|
||||
CONF_ON_COMMAND_SENT = "on_command_sent"
|
||||
CONF_RAW_ENCODE = "raw_encode"
|
||||
CONF_REGISTER_COUNT = "register_count"
|
||||
CONF_REGISTER_TYPE = "register_type"
|
||||
|
|
|
@ -43,7 +43,11 @@ bool ModbusController::send_next_command_() {
|
|||
ESP_LOGV(TAG, "Sending next modbus command to device %d register 0x%02X count %d", this->address_,
|
||||
command->register_address, command->register_count);
|
||||
command->send();
|
||||
|
||||
this->last_command_timestamp_ = millis();
|
||||
|
||||
this->command_sent_callback_.call((int) command->function_code, command->register_address);
|
||||
|
||||
// remove from queue if no handler is defined
|
||||
if (!command->on_data_func) {
|
||||
command_queue_.pop_front();
|
||||
|
@ -659,5 +663,9 @@ int64_t payload_to_number(const std::vector<uint8_t> &data, SensorValueType sens
|
|||
return value;
|
||||
}
|
||||
|
||||
void ModbusController::add_on_command_sent_callback(std::function<void(int, int)> &&callback) {
|
||||
this->command_sent_callback_.add(std::move(callback));
|
||||
}
|
||||
|
||||
} // namespace modbus_controller
|
||||
} // namespace esphome
|
||||
|
|
|
@ -456,6 +456,8 @@ class ModbusController : public PollingComponent, public modbus::ModbusDevice {
|
|||
size_t get_command_queue_length() { return command_queue_.size(); }
|
||||
/// get if the module is offline, didn't respond the last command
|
||||
bool get_module_offline() { return module_offline_; }
|
||||
/// Set callback for commands
|
||||
void add_on_command_sent_callback(std::function<void(int, int)> &&callback);
|
||||
|
||||
protected:
|
||||
/// parse sensormap_ and create range of sequential addresses
|
||||
|
@ -488,6 +490,7 @@ class ModbusController : public PollingComponent, public modbus::ModbusDevice {
|
|||
bool module_offline_;
|
||||
/// how many updates to skip if module is offline
|
||||
uint16_t offline_skip_updates_;
|
||||
CallbackManager<void(int, int)> command_sent_callback_{};
|
||||
};
|
||||
|
||||
/** Convert vector<uint8_t> response payload to float.
|
||||
|
|
Loading…