Check DHT sensor exists before publishing (#850)
Fixes https://github.com/esphome/issues/issues/841
This commit is contained in:
parent
74878276fc
commit
7c0d777173
1 changed files with 8 additions and 4 deletions
|
@ -47,7 +47,9 @@ void DHT::update() {
|
|||
if (error) {
|
||||
ESP_LOGD(TAG, "Got Temperature=%.1f°C Humidity=%.1f%%", temperature, humidity);
|
||||
|
||||
if (this->temperature_sensor_ != nullptr)
|
||||
this->temperature_sensor_->publish_state(temperature);
|
||||
if (this->humidity_sensor_ != nullptr)
|
||||
this->humidity_sensor_->publish_state(humidity);
|
||||
this->status_clear_warning();
|
||||
} else {
|
||||
|
@ -56,7 +58,9 @@ void DHT::update() {
|
|||
str = " and consider manually specifying the DHT model using the model option";
|
||||
}
|
||||
ESP_LOGW(TAG, "Invalid readings! Please check your wiring (pull-up resistor, pin number)%s.", str);
|
||||
if (this->temperature_sensor_ != nullptr)
|
||||
this->temperature_sensor_->publish_state(NAN);
|
||||
if (this->humidity_sensor_ != nullptr)
|
||||
this->humidity_sensor_->publish_state(NAN);
|
||||
this->status_set_warning();
|
||||
}
|
||||
|
|