[Modbus Controller] Added on_online
and on_offline
automation (#7417)
This commit is contained in:
parent
b367c01b4b
commit
7d75c9157b
7 changed files with 78 additions and 3 deletions
|
@ -25,6 +25,8 @@ from .const import (
|
||||||
CONF_MODBUS_CONTROLLER_ID,
|
CONF_MODBUS_CONTROLLER_ID,
|
||||||
CONF_OFFLINE_SKIP_UPDATES,
|
CONF_OFFLINE_SKIP_UPDATES,
|
||||||
CONF_ON_COMMAND_SENT,
|
CONF_ON_COMMAND_SENT,
|
||||||
|
CONF_ON_ONLINE,
|
||||||
|
CONF_ON_OFFLINE,
|
||||||
CONF_REGISTER_COUNT,
|
CONF_REGISTER_COUNT,
|
||||||
CONF_REGISTER_TYPE,
|
CONF_REGISTER_TYPE,
|
||||||
CONF_RESPONSE_SIZE,
|
CONF_RESPONSE_SIZE,
|
||||||
|
@ -114,6 +116,14 @@ ModbusCommandSentTrigger = modbus_controller_ns.class_(
|
||||||
"ModbusCommandSentTrigger", automation.Trigger.template(cg.int_, cg.int_)
|
"ModbusCommandSentTrigger", automation.Trigger.template(cg.int_, cg.int_)
|
||||||
)
|
)
|
||||||
|
|
||||||
|
ModbusOnlineTrigger = modbus_controller_ns.class_(
|
||||||
|
"ModbusOnlineTrigger", automation.Trigger.template(cg.int_, cg.int_)
|
||||||
|
)
|
||||||
|
|
||||||
|
ModbusOfflineTrigger = modbus_controller_ns.class_(
|
||||||
|
"ModbusOfflineTrigger", automation.Trigger.template(cg.int_, cg.int_)
|
||||||
|
)
|
||||||
|
|
||||||
_LOGGER = logging.getLogger(__name__)
|
_LOGGER = logging.getLogger(__name__)
|
||||||
|
|
||||||
ModbusServerRegisterSchema = cv.Schema(
|
ModbusServerRegisterSchema = cv.Schema(
|
||||||
|
@ -146,6 +156,16 @@ CONFIG_SCHEMA = cv.All(
|
||||||
),
|
),
|
||||||
}
|
}
|
||||||
),
|
),
|
||||||
|
cv.Optional(CONF_ON_ONLINE): automation.validate_automation(
|
||||||
|
{
|
||||||
|
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(ModbusOnlineTrigger),
|
||||||
|
}
|
||||||
|
),
|
||||||
|
cv.Optional(CONF_ON_OFFLINE): automation.validate_automation(
|
||||||
|
{
|
||||||
|
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(ModbusOnlineTrigger),
|
||||||
|
}
|
||||||
|
),
|
||||||
}
|
}
|
||||||
)
|
)
|
||||||
.extend(cv.polling_component_schema("60s"))
|
.extend(cv.polling_component_schema("60s"))
|
||||||
|
@ -284,7 +304,17 @@ async def to_code(config):
|
||||||
for conf in config.get(CONF_ON_COMMAND_SENT, []):
|
for conf in config.get(CONF_ON_COMMAND_SENT, []):
|
||||||
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
|
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
|
||||||
await automation.build_automation(
|
await automation.build_automation(
|
||||||
trigger, [(int, "function_code"), (int, "address")], conf
|
trigger, [(cg.int_, "function_code"), (cg.int_, "address")], conf
|
||||||
|
)
|
||||||
|
for conf in config.get(CONF_ON_ONLINE, []):
|
||||||
|
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
|
||||||
|
await automation.build_automation(
|
||||||
|
trigger, [(cg.int_, "function_code"), (cg.int_, "address")], conf
|
||||||
|
)
|
||||||
|
for conf in config.get(CONF_ON_OFFLINE, []):
|
||||||
|
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
|
||||||
|
await automation.build_automation(
|
||||||
|
trigger, [(cg.int_, "function_code"), (cg.int_, "address")], conf
|
||||||
)
|
)
|
||||||
|
|
||||||
|
|
||||||
|
|
|
@ -15,5 +15,21 @@ class ModbusCommandSentTrigger : public Trigger<int, int> {
|
||||||
}
|
}
|
||||||
};
|
};
|
||||||
|
|
||||||
|
class ModbusOnlineTrigger : public Trigger<int, int> {
|
||||||
|
public:
|
||||||
|
ModbusOnlineTrigger(ModbusController *a_modbuscontroller) {
|
||||||
|
a_modbuscontroller->add_on_online_callback(
|
||||||
|
[this](int function_code, int address) { this->trigger(function_code, address); });
|
||||||
|
}
|
||||||
|
};
|
||||||
|
|
||||||
|
class ModbusOfflineTrigger : public Trigger<int, int> {
|
||||||
|
public:
|
||||||
|
ModbusOfflineTrigger(ModbusController *a_modbuscontroller) {
|
||||||
|
a_modbuscontroller->add_on_offline_callback(
|
||||||
|
[this](int function_code, int address) { this->trigger(function_code, address); });
|
||||||
|
}
|
||||||
|
};
|
||||||
|
|
||||||
} // namespace modbus_controller
|
} // namespace modbus_controller
|
||||||
} // namespace esphome
|
} // namespace esphome
|
||||||
|
|
|
@ -9,6 +9,8 @@ CONF_MAX_CMD_RETRIES = "max_cmd_retries"
|
||||||
CONF_MODBUS_CONTROLLER_ID = "modbus_controller_id"
|
CONF_MODBUS_CONTROLLER_ID = "modbus_controller_id"
|
||||||
CONF_MODBUS_FUNCTIONCODE = "modbus_functioncode"
|
CONF_MODBUS_FUNCTIONCODE = "modbus_functioncode"
|
||||||
CONF_ON_COMMAND_SENT = "on_command_sent"
|
CONF_ON_COMMAND_SENT = "on_command_sent"
|
||||||
|
CONF_ON_ONLINE = "on_online"
|
||||||
|
CONF_ON_OFFLINE = "on_offline"
|
||||||
CONF_RAW_ENCODE = "raw_encode"
|
CONF_RAW_ENCODE = "raw_encode"
|
||||||
CONF_REGISTER_COUNT = "register_count"
|
CONF_REGISTER_COUNT = "register_count"
|
||||||
CONF_REGISTER_TYPE = "register_type"
|
CONF_REGISTER_TYPE = "register_type"
|
||||||
|
|
|
@ -32,8 +32,10 @@ bool ModbusController::send_next_command_() {
|
||||||
r.skip_updates_counter = this->offline_skip_updates_;
|
r.skip_updates_counter = this->offline_skip_updates_;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
|
||||||
this->module_offline_ = true;
|
this->module_offline_ = true;
|
||||||
|
this->offline_callback_.call((int) command->function_code, command->register_address);
|
||||||
|
}
|
||||||
ESP_LOGD(TAG, "Modbus command to device=%d register=0x%02X no response received - removed from send queue",
|
ESP_LOGD(TAG, "Modbus command to device=%d register=0x%02X no response received - removed from send queue",
|
||||||
this->address_, command->register_address);
|
this->address_, command->register_address);
|
||||||
this->command_queue_.pop_front();
|
this->command_queue_.pop_front();
|
||||||
|
@ -68,8 +70,10 @@ void ModbusController::on_modbus_data(const std::vector<uint8_t> &data) {
|
||||||
r.skip_updates_counter = 0;
|
r.skip_updates_counter = 0;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
}
|
// Restore module online state
|
||||||
this->module_offline_ = false;
|
this->module_offline_ = false;
|
||||||
|
this->online_callback_.call((int) current_command->function_code, current_command->register_address);
|
||||||
|
}
|
||||||
|
|
||||||
// Move the commandItem to the response queue
|
// Move the commandItem to the response queue
|
||||||
current_command->payload = data;
|
current_command->payload = data;
|
||||||
|
@ -670,5 +674,13 @@ void ModbusController::add_on_command_sent_callback(std::function<void(int, int)
|
||||||
this->command_sent_callback_.add(std::move(callback));
|
this->command_sent_callback_.add(std::move(callback));
|
||||||
}
|
}
|
||||||
|
|
||||||
|
void ModbusController::add_on_online_callback(std::function<void(int, int)> &&callback) {
|
||||||
|
this->online_callback_.add(std::move(callback));
|
||||||
|
}
|
||||||
|
|
||||||
|
void ModbusController::add_on_offline_callback(std::function<void(int, int)> &&callback) {
|
||||||
|
this->offline_callback_.add(std::move(callback));
|
||||||
|
}
|
||||||
|
|
||||||
} // namespace modbus_controller
|
} // namespace modbus_controller
|
||||||
} // namespace esphome
|
} // namespace esphome
|
||||||
|
|
|
@ -468,6 +468,10 @@ class ModbusController : public PollingComponent, public modbus::ModbusDevice {
|
||||||
bool get_module_offline() { return module_offline_; }
|
bool get_module_offline() { return module_offline_; }
|
||||||
/// Set callback for commands
|
/// Set callback for commands
|
||||||
void add_on_command_sent_callback(std::function<void(int, int)> &&callback);
|
void add_on_command_sent_callback(std::function<void(int, int)> &&callback);
|
||||||
|
/// Set callback for online changes
|
||||||
|
void add_on_online_callback(std::function<void(int, int)> &&callback);
|
||||||
|
/// Set callback for offline changes
|
||||||
|
void add_on_offline_callback(std::function<void(int, int)> &&callback);
|
||||||
/// called by esphome generated code to set the max_cmd_retries.
|
/// called by esphome generated code to set the max_cmd_retries.
|
||||||
void set_max_cmd_retries(uint8_t max_cmd_retries) { this->max_cmd_retries_ = max_cmd_retries; }
|
void set_max_cmd_retries(uint8_t max_cmd_retries) { this->max_cmd_retries_ = max_cmd_retries; }
|
||||||
/// get how many times a command will be (re)sent if no response is received
|
/// get how many times a command will be (re)sent if no response is received
|
||||||
|
@ -508,7 +512,12 @@ class ModbusController : public PollingComponent, public modbus::ModbusDevice {
|
||||||
uint16_t offline_skip_updates_;
|
uint16_t offline_skip_updates_;
|
||||||
/// How many times we will retry a command if we get no response
|
/// How many times we will retry a command if we get no response
|
||||||
uint8_t max_cmd_retries_{4};
|
uint8_t max_cmd_retries_{4};
|
||||||
|
/// Command sent callback
|
||||||
CallbackManager<void(int, int)> command_sent_callback_{};
|
CallbackManager<void(int, int)> command_sent_callback_{};
|
||||||
|
/// Server online callback
|
||||||
|
CallbackManager<void(int, int)> online_callback_{};
|
||||||
|
/// Server offline callback
|
||||||
|
CallbackManager<void(int, int)> offline_callback_{};
|
||||||
};
|
};
|
||||||
|
|
||||||
/** Convert vector<uint8_t> response payload to float.
|
/** Convert vector<uint8_t> response payload to float.
|
||||||
|
|
|
@ -21,6 +21,9 @@ modbus_controller:
|
||||||
address: 0x2
|
address: 0x2
|
||||||
modbus_id: mod_bus1
|
modbus_id: mod_bus1
|
||||||
allow_duplicate_commands: false
|
allow_duplicate_commands: false
|
||||||
|
on_online:
|
||||||
|
then:
|
||||||
|
logger.log: "Module Online"
|
||||||
- id: modbus_controller2
|
- id: modbus_controller2
|
||||||
address: 0x2
|
address: 0x2
|
||||||
modbus_id: mod_bus2
|
modbus_id: mod_bus2
|
||||||
|
|
|
@ -13,4 +13,7 @@ modbus_controller:
|
||||||
address: 0x2
|
address: 0x2
|
||||||
modbus_id: mod_bus1
|
modbus_id: mod_bus1
|
||||||
allow_duplicate_commands: true
|
allow_duplicate_commands: true
|
||||||
|
on_offline:
|
||||||
|
then:
|
||||||
|
logger.log: "Module Offline"
|
||||||
max_cmd_retries: 10
|