airthings_wave: refactor to eliminate code duplication (#4910)

This commit is contained in:
Kevin P. Fleming 2023-06-20 19:53:44 -04:00 committed by GitHub
parent cb5a01da29
commit 8bd9f50659
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23
11 changed files with 317 additions and 371 deletions

View file

@ -17,6 +17,7 @@ esphome/components/adc/* @esphome/core
esphome/components/adc128s102/* @DeerMaximum
esphome/components/addressable_light/* @justfalter
esphome/components/airthings_ble/* @jeromelaban
esphome/components/airthings_wave_base/* @jeromelaban @ncareau
esphome/components/airthings_wave_mini/* @ncareau
esphome/components/airthings_wave_plus/* @jeromelaban
esphome/components/alarm_control_panel/* @grahambrown11

View file

@ -0,0 +1,81 @@
import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import sensor, ble_client
from esphome.const import (
DEVICE_CLASS_HUMIDITY,
DEVICE_CLASS_TEMPERATURE,
DEVICE_CLASS_PRESSURE,
STATE_CLASS_MEASUREMENT,
UNIT_PERCENT,
UNIT_CELSIUS,
UNIT_HECTOPASCAL,
CONF_HUMIDITY,
CONF_TVOC,
CONF_PRESSURE,
CONF_TEMPERATURE,
UNIT_PARTS_PER_BILLION,
ICON_RADIATOR,
)
CODEOWNERS = ["@ncareau", "@jeromelaban"]
DEPENDENCIES = ["ble_client"]
airthings_wave_base_ns = cg.esphome_ns.namespace("airthings_wave_base")
AirthingsWaveBase = airthings_wave_base_ns.class_(
"AirthingsWaveBase", cg.PollingComponent, ble_client.BLEClientNode
)
BASE_SCHEMA = (
sensor.SENSOR_SCHEMA.extend(
{
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
unit_of_measurement=UNIT_PERCENT,
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
accuracy_decimals=0,
),
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
unit_of_measurement=UNIT_HECTOPASCAL,
accuracy_decimals=1,
device_class=DEVICE_CLASS_PRESSURE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_TVOC): sensor.sensor_schema(
unit_of_measurement=UNIT_PARTS_PER_BILLION,
icon=ICON_RADIATOR,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
}
)
.extend(cv.polling_component_schema("5min"))
.extend(ble_client.BLE_CLIENT_SCHEMA)
)
async def wave_base_to_code(var, config):
await cg.register_component(var, config)
await ble_client.register_ble_node(var, config)
if CONF_HUMIDITY in config:
sens = await sensor.new_sensor(config[CONF_HUMIDITY])
cg.add(var.set_humidity(sens))
if CONF_TEMPERATURE in config:
sens = await sensor.new_sensor(config[CONF_TEMPERATURE])
cg.add(var.set_temperature(sens))
if CONF_PRESSURE in config:
sens = await sensor.new_sensor(config[CONF_PRESSURE])
cg.add(var.set_pressure(sens))
if CONF_TVOC in config:
sens = await sensor.new_sensor(config[CONF_TVOC])
cg.add(var.set_tvoc(sens))

View file

@ -0,0 +1,83 @@
#include "airthings_wave_base.h"
#ifdef USE_ESP32
namespace esphome {
namespace airthings_wave_base {
static const char *const TAG = "airthings_wave_base";
void AirthingsWaveBase::gattc_event_handler(esp_gattc_cb_event_t event, esp_gatt_if_t gattc_if,
esp_ble_gattc_cb_param_t *param) {
switch (event) {
case ESP_GATTC_OPEN_EVT: {
if (param->open.status == ESP_GATT_OK) {
ESP_LOGI(TAG, "Connected successfully!");
}
break;
}
case ESP_GATTC_DISCONNECT_EVT: {
ESP_LOGW(TAG, "Disconnected!");
break;
}
case ESP_GATTC_SEARCH_CMPL_EVT: {
this->handle_ = 0;
auto *chr = this->parent()->get_characteristic(this->service_uuid_, this->sensors_data_characteristic_uuid_);
if (chr == nullptr) {
ESP_LOGW(TAG, "No sensor characteristic found at service %s char %s", this->service_uuid_.to_string().c_str(),
this->sensors_data_characteristic_uuid_.to_string().c_str());
break;
}
this->handle_ = chr->handle;
this->node_state = esp32_ble_tracker::ClientState::ESTABLISHED;
this->request_read_values_();
break;
}
case ESP_GATTC_READ_CHAR_EVT: {
if (param->read.conn_id != this->parent()->get_conn_id())
break;
if (param->read.status != ESP_GATT_OK) {
ESP_LOGW(TAG, "Error reading char at handle %d, status=%d", param->read.handle, param->read.status);
break;
}
if (param->read.handle == this->handle_) {
this->read_sensors(param->read.value, param->read.value_len);
}
break;
}
default:
break;
}
}
bool AirthingsWaveBase::is_valid_voc_value_(uint16_t voc) { return 0 <= voc && voc <= 16383; }
void AirthingsWaveBase::update() {
if (this->node_state != esp32_ble_tracker::ClientState::ESTABLISHED) {
if (!this->parent()->enabled) {
ESP_LOGW(TAG, "Reconnecting to device");
this->parent()->set_enabled(true);
this->parent()->connect();
} else {
ESP_LOGW(TAG, "Connection in progress");
}
}
}
void AirthingsWaveBase::request_read_values_() {
auto status = esp_ble_gattc_read_char(this->parent()->get_gattc_if(), this->parent()->get_conn_id(), this->handle_,
ESP_GATT_AUTH_REQ_NONE);
if (status) {
ESP_LOGW(TAG, "Error sending read request for sensor, status=%d", status);
}
}
} // namespace airthings_wave_base
} // namespace esphome
#endif // USE_ESP32

View file

@ -0,0 +1,50 @@
#pragma once
#ifdef USE_ESP32
#include <esp_gattc_api.h>
#include <algorithm>
#include <iterator>
#include "esphome/components/ble_client/ble_client.h"
#include "esphome/components/esp32_ble_tracker/esp32_ble_tracker.h"
#include "esphome/components/sensor/sensor.h"
#include "esphome/core/component.h"
#include "esphome/core/log.h"
namespace esphome {
namespace airthings_wave_base {
class AirthingsWaveBase : public PollingComponent, public ble_client::BLEClientNode {
public:
AirthingsWaveBase() = default;
void update() override;
void gattc_event_handler(esp_gattc_cb_event_t event, esp_gatt_if_t gattc_if,
esp_ble_gattc_cb_param_t *param) override;
void set_temperature(sensor::Sensor *temperature) { temperature_sensor_ = temperature; }
void set_humidity(sensor::Sensor *humidity) { humidity_sensor_ = humidity; }
void set_pressure(sensor::Sensor *pressure) { pressure_sensor_ = pressure; }
void set_tvoc(sensor::Sensor *tvoc) { tvoc_sensor_ = tvoc; }
protected:
bool is_valid_voc_value_(uint16_t voc);
virtual void read_sensors(uint8_t *value, uint16_t value_len) = 0;
void request_read_values_();
sensor::Sensor *temperature_sensor_{nullptr};
sensor::Sensor *humidity_sensor_{nullptr};
sensor::Sensor *pressure_sensor_{nullptr};
sensor::Sensor *tvoc_sensor_{nullptr};
uint16_t handle_;
esp32_ble_tracker::ESPBTUUID service_uuid_;
esp32_ble_tracker::ESPBTUUID sensors_data_characteristic_uuid_;
};
} // namespace airthings_wave_base
} // namespace esphome
#endif // USE_ESP32

View file

@ -7,105 +7,47 @@ namespace airthings_wave_mini {
static const char *const TAG = "airthings_wave_mini";
void AirthingsWaveMini::gattc_event_handler(esp_gattc_cb_event_t event, esp_gatt_if_t gattc_if,
esp_ble_gattc_cb_param_t *param) {
switch (event) {
case ESP_GATTC_OPEN_EVT: {
if (param->open.status == ESP_GATT_OK) {
ESP_LOGI(TAG, "Connected successfully!");
}
break;
}
case ESP_GATTC_DISCONNECT_EVT: {
ESP_LOGW(TAG, "Disconnected!");
break;
}
case ESP_GATTC_SEARCH_CMPL_EVT: {
this->handle_ = 0;
auto *chr = this->parent()->get_characteristic(service_uuid_, sensors_data_characteristic_uuid_);
if (chr == nullptr) {
ESP_LOGW(TAG, "No sensor characteristic found at service %s char %s", service_uuid_.to_string().c_str(),
sensors_data_characteristic_uuid_.to_string().c_str());
break;
}
this->handle_ = chr->handle;
this->node_state = esp32_ble_tracker::ClientState::ESTABLISHED;
request_read_values_();
break;
}
case ESP_GATTC_READ_CHAR_EVT: {
if (param->read.conn_id != this->parent()->get_conn_id())
break;
if (param->read.status != ESP_GATT_OK) {
ESP_LOGW(TAG, "Error reading char at handle %d, status=%d", param->read.handle, param->read.status);
break;
}
if (param->read.handle == this->handle_) {
read_sensors_(param->read.value, param->read.value_len);
}
break;
}
default:
break;
}
}
void AirthingsWaveMini::read_sensors_(uint8_t *raw_value, uint16_t value_len) {
void AirthingsWaveMini::read_sensors(uint8_t *raw_value, uint16_t value_len) {
auto *value = (WaveMiniReadings *) raw_value;
if (sizeof(WaveMiniReadings) <= value_len) {
this->humidity_sensor_->publish_state(value->humidity / 100.0f);
this->pressure_sensor_->publish_state(value->pressure / 50.0f);
this->temperature_sensor_->publish_state(value->temperature / 100.0f - 273.15f);
if (is_valid_voc_value_(value->voc)) {
if (this->humidity_sensor_ != nullptr) {
this->humidity_sensor_->publish_state(value->humidity / 100.0f);
}
if (this->pressure_sensor_ != nullptr) {
this->pressure_sensor_->publish_state(value->pressure / 50.0f);
}
if (this->temperature_sensor_ != nullptr) {
this->temperature_sensor_->publish_state(value->temperature / 100.0f - 273.15f);
}
if ((this->tvoc_sensor_ != nullptr) && this->is_valid_voc_value_(value->voc)) {
this->tvoc_sensor_->publish_state(value->voc);
}
// This instance must not stay connected
// so other clients can connect to it (e.g. the
// mobile app).
parent()->set_enabled(false);
}
}
bool AirthingsWaveMini::is_valid_voc_value_(uint16_t voc) { return 0 <= voc && voc <= 16383; }
void AirthingsWaveMini::update() {
if (this->node_state != esp32_ble_tracker::ClientState::ESTABLISHED) {
if (!parent()->enabled) {
ESP_LOGW(TAG, "Reconnecting to device");
parent()->set_enabled(true);
parent()->connect();
} else {
ESP_LOGW(TAG, "Connection in progress");
}
}
}
void AirthingsWaveMini::request_read_values_() {
auto status = esp_ble_gattc_read_char(this->parent()->get_gattc_if(), this->parent()->get_conn_id(), this->handle_,
ESP_GATT_AUTH_REQ_NONE);
if (status) {
ESP_LOGW(TAG, "Error sending read request for sensor, status=%d", status);
this->parent()->set_enabled(false);
}
}
void AirthingsWaveMini::dump_config() {
// these really don't belong here, but there doesn't seem to be a
// practical way to have the base class use LOG_SENSOR and include
// the TAG from this component
LOG_SENSOR(" ", "Humidity", this->humidity_sensor_);
LOG_SENSOR(" ", "Temperature", this->temperature_sensor_);
LOG_SENSOR(" ", "Pressure", this->pressure_sensor_);
LOG_SENSOR(" ", "TVOC", this->tvoc_sensor_);
}
AirthingsWaveMini::AirthingsWaveMini()
: PollingComponent(10000),
service_uuid_(esp32_ble_tracker::ESPBTUUID::from_raw(SERVICE_UUID)),
sensors_data_characteristic_uuid_(esp32_ble_tracker::ESPBTUUID::from_raw(CHARACTERISTIC_UUID)) {}
AirthingsWaveMini::AirthingsWaveMini() {
this->service_uuid_ = esp32_ble_tracker::ESPBTUUID::from_raw(SERVICE_UUID);
this->sensors_data_characteristic_uuid_ = esp32_ble_tracker::ESPBTUUID::from_raw(CHARACTERISTIC_UUID);
}
} // namespace airthings_wave_mini
} // namespace esphome

View file

@ -2,14 +2,7 @@
#ifdef USE_ESP32
#include <esp_gattc_api.h>
#include <algorithm>
#include <iterator>
#include "esphome/components/ble_client/ble_client.h"
#include "esphome/components/esp32_ble_tracker/esp32_ble_tracker.h"
#include "esphome/components/sensor/sensor.h"
#include "esphome/core/component.h"
#include "esphome/core/log.h"
#include "esphome/components/airthings_wave_base/airthings_wave_base.h"
namespace esphome {
namespace airthings_wave_mini {
@ -17,35 +10,14 @@ namespace airthings_wave_mini {
static const char *const SERVICE_UUID = "b42e3882-ade7-11e4-89d3-123b93f75cba";
static const char *const CHARACTERISTIC_UUID = "b42e3b98-ade7-11e4-89d3-123b93f75cba";
class AirthingsWaveMini : public PollingComponent, public ble_client::BLEClientNode {
class AirthingsWaveMini : public airthings_wave_base::AirthingsWaveBase {
public:
AirthingsWaveMini();
void dump_config() override;
void update() override;
void gattc_event_handler(esp_gattc_cb_event_t event, esp_gatt_if_t gattc_if,
esp_ble_gattc_cb_param_t *param) override;
void set_temperature(sensor::Sensor *temperature) { temperature_sensor_ = temperature; }
void set_humidity(sensor::Sensor *humidity) { humidity_sensor_ = humidity; }
void set_pressure(sensor::Sensor *pressure) { pressure_sensor_ = pressure; }
void set_tvoc(sensor::Sensor *tvoc) { tvoc_sensor_ = tvoc; }
protected:
bool is_valid_voc_value_(uint16_t voc);
void read_sensors_(uint8_t *value, uint16_t value_len);
void request_read_values_();
sensor::Sensor *temperature_sensor_{nullptr};
sensor::Sensor *humidity_sensor_{nullptr};
sensor::Sensor *pressure_sensor_{nullptr};
sensor::Sensor *tvoc_sensor_{nullptr};
uint16_t handle_;
esp32_ble_tracker::ESPBTUUID service_uuid_;
esp32_ble_tracker::ESPBTUUID sensors_data_characteristic_uuid_;
void read_sensors(uint8_t *value, uint16_t value_len) override;
struct WaveMiniReadings {
uint16_t unused01;

View file

@ -1,82 +1,28 @@
import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import sensor, ble_client
from esphome.components import airthings_wave_base
from esphome.const import (
DEVICE_CLASS_HUMIDITY,
DEVICE_CLASS_TEMPERATURE,
DEVICE_CLASS_PRESSURE,
STATE_CLASS_MEASUREMENT,
UNIT_PERCENT,
UNIT_CELSIUS,
UNIT_HECTOPASCAL,
CONF_ID,
CONF_HUMIDITY,
CONF_TVOC,
CONF_PRESSURE,
CONF_TEMPERATURE,
UNIT_PARTS_PER_BILLION,
ICON_RADIATOR,
)
DEPENDENCIES = ["ble_client"]
DEPENDENCIES = airthings_wave_base.DEPENDENCIES
AUTO_LOAD = ["airthings_wave_base"]
airthings_wave_mini_ns = cg.esphome_ns.namespace("airthings_wave_mini")
AirthingsWaveMini = airthings_wave_mini_ns.class_(
"AirthingsWaveMini", cg.PollingComponent, ble_client.BLEClientNode
"AirthingsWaveMini", airthings_wave_base.AirthingsWaveBase
)
CONFIG_SCHEMA = cv.All(
cv.Schema(
{
cv.GenerateID(): cv.declare_id(AirthingsWaveMini),
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
unit_of_measurement=UNIT_PERCENT,
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
accuracy_decimals=2,
),
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
unit_of_measurement=UNIT_HECTOPASCAL,
accuracy_decimals=2,
device_class=DEVICE_CLASS_PRESSURE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_TVOC): sensor.sensor_schema(
unit_of_measurement=UNIT_PARTS_PER_BILLION,
icon=ICON_RADIATOR,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
}
)
.extend(cv.polling_component_schema("5min"))
.extend(ble_client.BLE_CLIENT_SCHEMA),
CONFIG_SCHEMA = airthings_wave_base.BASE_SCHEMA.extend(
{
cv.GenerateID(): cv.declare_id(AirthingsWaveMini),
}
)
async def to_code(config):
var = cg.new_Pvariable(config[CONF_ID])
await cg.register_component(var, config)
await ble_client.register_ble_node(var, config)
if CONF_HUMIDITY in config:
sens = await sensor.new_sensor(config[CONF_HUMIDITY])
cg.add(var.set_humidity(sens))
if CONF_TEMPERATURE in config:
sens = await sensor.new_sensor(config[CONF_TEMPERATURE])
cg.add(var.set_temperature(sens))
if CONF_PRESSURE in config:
sens = await sensor.new_sensor(config[CONF_PRESSURE])
cg.add(var.set_pressure(sens))
if CONF_TVOC in config:
sens = await sensor.new_sensor(config[CONF_TVOC])
cg.add(var.set_tvoc(sens))
await airthings_wave_base.wave_base_to_code(var, config)

View file

@ -7,55 +7,7 @@ namespace airthings_wave_plus {
static const char *const TAG = "airthings_wave_plus";
void AirthingsWavePlus::gattc_event_handler(esp_gattc_cb_event_t event, esp_gatt_if_t gattc_if,
esp_ble_gattc_cb_param_t *param) {
switch (event) {
case ESP_GATTC_OPEN_EVT: {
if (param->open.status == ESP_GATT_OK) {
ESP_LOGI(TAG, "Connected successfully!");
}
break;
}
case ESP_GATTC_DISCONNECT_EVT: {
ESP_LOGW(TAG, "Disconnected!");
break;
}
case ESP_GATTC_SEARCH_CMPL_EVT: {
this->handle_ = 0;
auto *chr = this->parent()->get_characteristic(service_uuid_, sensors_data_characteristic_uuid_);
if (chr == nullptr) {
ESP_LOGW(TAG, "No sensor characteristic found at service %s char %s", service_uuid_.to_string().c_str(),
sensors_data_characteristic_uuid_.to_string().c_str());
break;
}
this->handle_ = chr->handle;
this->node_state = esp32_ble_tracker::ClientState::ESTABLISHED;
request_read_values_();
break;
}
case ESP_GATTC_READ_CHAR_EVT: {
if (param->read.conn_id != this->parent()->get_conn_id())
break;
if (param->read.status != ESP_GATT_OK) {
ESP_LOGW(TAG, "Error reading char at handle %d, status=%d", param->read.handle, param->read.status);
break;
}
if (param->read.handle == this->handle_) {
read_sensors_(param->read.value, param->read.value_len);
}
break;
}
default:
break;
}
}
void AirthingsWavePlus::read_sensors_(uint8_t *raw_value, uint16_t value_len) {
void AirthingsWavePlus::read_sensors(uint8_t *raw_value, uint16_t value_len) {
auto *value = (WavePlusReadings *) raw_value;
if (sizeof(WavePlusReadings) <= value_len) {
@ -64,26 +16,38 @@ void AirthingsWavePlus::read_sensors_(uint8_t *raw_value, uint16_t value_len) {
if (value->version == 1) {
ESP_LOGD(TAG, "ambient light = %d", value->ambientLight);
this->humidity_sensor_->publish_state(value->humidity / 2.0f);
if (is_valid_radon_value_(value->radon)) {
if (this->humidity_sensor_ != nullptr) {
this->humidity_sensor_->publish_state(value->humidity / 2.0f);
}
if ((this->radon_sensor_ != nullptr) && this->is_valid_radon_value_(value->radon)) {
this->radon_sensor_->publish_state(value->radon);
}
if (is_valid_radon_value_(value->radon_lt)) {
if ((this->radon_long_term_sensor_ != nullptr) && this->is_valid_radon_value_(value->radon_lt)) {
this->radon_long_term_sensor_->publish_state(value->radon_lt);
}
this->temperature_sensor_->publish_state(value->temperature / 100.0f);
this->pressure_sensor_->publish_state(value->pressure / 50.0f);
if (is_valid_co2_value_(value->co2)) {
if (this->temperature_sensor_ != nullptr) {
this->temperature_sensor_->publish_state(value->temperature / 100.0f);
}
if (this->pressure_sensor_ != nullptr) {
this->pressure_sensor_->publish_state(value->pressure / 50.0f);
}
if ((this->co2_sensor_ != nullptr) && this->is_valid_co2_value_(value->co2)) {
this->co2_sensor_->publish_state(value->co2);
}
if (is_valid_voc_value_(value->voc)) {
if ((this->tvoc_sensor_ != nullptr) && this->is_valid_voc_value_(value->voc)) {
this->tvoc_sensor_->publish_state(value->voc);
}
// This instance must not stay connected
// so other clients can connect to it (e.g. the
// mobile app).
parent()->set_enabled(false);
this->parent()->set_enabled(false);
} else {
ESP_LOGE(TAG, "Invalid payload version (%d != 1, newer version or not a Wave Plus?)", value->version);
}
@ -92,44 +56,26 @@ void AirthingsWavePlus::read_sensors_(uint8_t *raw_value, uint16_t value_len) {
bool AirthingsWavePlus::is_valid_radon_value_(uint16_t radon) { return 0 <= radon && radon <= 16383; }
bool AirthingsWavePlus::is_valid_voc_value_(uint16_t voc) { return 0 <= voc && voc <= 16383; }
bool AirthingsWavePlus::is_valid_co2_value_(uint16_t co2) { return 0 <= co2 && co2 <= 16383; }
void AirthingsWavePlus::update() {
if (this->node_state != esp32_ble_tracker::ClientState::ESTABLISHED) {
if (!parent()->enabled) {
ESP_LOGW(TAG, "Reconnecting to device");
parent()->set_enabled(true);
parent()->connect();
} else {
ESP_LOGW(TAG, "Connection in progress");
}
}
}
void AirthingsWavePlus::request_read_values_() {
auto status = esp_ble_gattc_read_char(this->parent()->get_gattc_if(), this->parent()->get_conn_id(), this->handle_,
ESP_GATT_AUTH_REQ_NONE);
if (status) {
ESP_LOGW(TAG, "Error sending read request for sensor, status=%d", status);
}
}
void AirthingsWavePlus::dump_config() {
// these really don't belong here, but there doesn't seem to be a
// practical way to have the base class use LOG_SENSOR and include
// the TAG from this component
LOG_SENSOR(" ", "Humidity", this->humidity_sensor_);
LOG_SENSOR(" ", "Radon", this->radon_sensor_);
LOG_SENSOR(" ", "Radon Long Term", this->radon_long_term_sensor_);
LOG_SENSOR(" ", "Temperature", this->temperature_sensor_);
LOG_SENSOR(" ", "Pressure", this->pressure_sensor_);
LOG_SENSOR(" ", "CO2", this->co2_sensor_);
LOG_SENSOR(" ", "TVOC", this->tvoc_sensor_);
LOG_SENSOR(" ", "Radon", this->radon_sensor_);
LOG_SENSOR(" ", "Radon Long Term", this->radon_long_term_sensor_);
LOG_SENSOR(" ", "CO2", this->co2_sensor_);
}
AirthingsWavePlus::AirthingsWavePlus()
: PollingComponent(10000),
service_uuid_(esp32_ble_tracker::ESPBTUUID::from_raw(SERVICE_UUID)),
sensors_data_characteristic_uuid_(esp32_ble_tracker::ESPBTUUID::from_raw(CHARACTERISTIC_UUID)) {}
AirthingsWavePlus::AirthingsWavePlus() {
this->service_uuid_ = esp32_ble_tracker::ESPBTUUID::from_raw(SERVICE_UUID);
this->sensors_data_characteristic_uuid_ = esp32_ble_tracker::ESPBTUUID::from_raw(CHARACTERISTIC_UUID);
}
} // namespace airthings_wave_plus
} // namespace esphome

View file

@ -2,14 +2,7 @@
#ifdef USE_ESP32
#include <esp_gattc_api.h>
#include <algorithm>
#include <iterator>
#include "esphome/components/ble_client/ble_client.h"
#include "esphome/components/esp32_ble_tracker/esp32_ble_tracker.h"
#include "esphome/components/sensor/sensor.h"
#include "esphome/core/component.h"
#include "esphome/core/log.h"
#include "esphome/components/airthings_wave_base/airthings_wave_base.h"
namespace esphome {
namespace airthings_wave_plus {
@ -17,43 +10,25 @@ namespace airthings_wave_plus {
static const char *const SERVICE_UUID = "b42e1c08-ade7-11e4-89d3-123b93f75cba";
static const char *const CHARACTERISTIC_UUID = "b42e2a68-ade7-11e4-89d3-123b93f75cba";
class AirthingsWavePlus : public PollingComponent, public ble_client::BLEClientNode {
class AirthingsWavePlus : public airthings_wave_base::AirthingsWaveBase {
public:
AirthingsWavePlus();
void dump_config() override;
void update() override;
void gattc_event_handler(esp_gattc_cb_event_t event, esp_gatt_if_t gattc_if,
esp_ble_gattc_cb_param_t *param) override;
void set_temperature(sensor::Sensor *temperature) { temperature_sensor_ = temperature; }
void set_radon(sensor::Sensor *radon) { radon_sensor_ = radon; }
void set_radon_long_term(sensor::Sensor *radon_long_term) { radon_long_term_sensor_ = radon_long_term; }
void set_humidity(sensor::Sensor *humidity) { humidity_sensor_ = humidity; }
void set_pressure(sensor::Sensor *pressure) { pressure_sensor_ = pressure; }
void set_co2(sensor::Sensor *co2) { co2_sensor_ = co2; }
void set_tvoc(sensor::Sensor *tvoc) { tvoc_sensor_ = tvoc; }
protected:
bool is_valid_radon_value_(uint16_t radon);
bool is_valid_voc_value_(uint16_t voc);
bool is_valid_co2_value_(uint16_t co2);
void read_sensors_(uint8_t *value, uint16_t value_len);
void request_read_values_();
void read_sensors(uint8_t *value, uint16_t value_len) override;
sensor::Sensor *temperature_sensor_{nullptr};
sensor::Sensor *radon_sensor_{nullptr};
sensor::Sensor *radon_long_term_sensor_{nullptr};
sensor::Sensor *humidity_sensor_{nullptr};
sensor::Sensor *pressure_sensor_{nullptr};
sensor::Sensor *co2_sensor_{nullptr};
sensor::Sensor *tvoc_sensor_{nullptr};
uint16_t handle_;
esp32_ble_tracker::ESPBTUUID service_uuid_;
esp32_ble_tracker::ESPBTUUID sensors_data_characteristic_uuid_;
struct WavePlusReadings {
uint8_t version;

View file

@ -1,116 +1,64 @@
import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import sensor, ble_client
from esphome.components import sensor, airthings_wave_base
from esphome.const import (
DEVICE_CLASS_CARBON_DIOXIDE,
DEVICE_CLASS_HUMIDITY,
DEVICE_CLASS_TEMPERATURE,
DEVICE_CLASS_PRESSURE,
STATE_CLASS_MEASUREMENT,
UNIT_PERCENT,
UNIT_CELSIUS,
UNIT_HECTOPASCAL,
ICON_RADIOACTIVE,
CONF_ID,
CONF_RADON,
CONF_RADON_LONG_TERM,
CONF_HUMIDITY,
CONF_TVOC,
CONF_CO2,
CONF_PRESSURE,
CONF_TEMPERATURE,
UNIT_BECQUEREL_PER_CUBIC_METER,
UNIT_PARTS_PER_MILLION,
UNIT_PARTS_PER_BILLION,
ICON_RADIATOR,
)
DEPENDENCIES = ["ble_client"]
DEPENDENCIES = airthings_wave_base.DEPENDENCIES
AUTO_LOAD = ["airthings_wave_base"]
airthings_wave_plus_ns = cg.esphome_ns.namespace("airthings_wave_plus")
AirthingsWavePlus = airthings_wave_plus_ns.class_(
"AirthingsWavePlus", cg.PollingComponent, ble_client.BLEClientNode
"AirthingsWavePlus", airthings_wave_base.AirthingsWaveBase
)
CONFIG_SCHEMA = cv.All(
cv.Schema(
{
cv.GenerateID(): cv.declare_id(AirthingsWavePlus),
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
unit_of_measurement=UNIT_PERCENT,
device_class=DEVICE_CLASS_HUMIDITY,
state_class=STATE_CLASS_MEASUREMENT,
accuracy_decimals=0,
),
cv.Optional(CONF_RADON): sensor.sensor_schema(
unit_of_measurement=UNIT_BECQUEREL_PER_CUBIC_METER,
icon=ICON_RADIOACTIVE,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_RADON_LONG_TERM): sensor.sensor_schema(
unit_of_measurement=UNIT_BECQUEREL_PER_CUBIC_METER,
icon=ICON_RADIOACTIVE,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
unit_of_measurement=UNIT_CELSIUS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_TEMPERATURE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
unit_of_measurement=UNIT_HECTOPASCAL,
accuracy_decimals=1,
device_class=DEVICE_CLASS_PRESSURE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_CO2): sensor.sensor_schema(
unit_of_measurement=UNIT_PARTS_PER_MILLION,
accuracy_decimals=0,
device_class=DEVICE_CLASS_CARBON_DIOXIDE,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_TVOC): sensor.sensor_schema(
unit_of_measurement=UNIT_PARTS_PER_BILLION,
icon=ICON_RADIATOR,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
}
)
.extend(cv.polling_component_schema("5min"))
.extend(ble_client.BLE_CLIENT_SCHEMA),
CONFIG_SCHEMA = airthings_wave_base.BASE_SCHEMA.extend(
{
cv.GenerateID(): cv.declare_id(AirthingsWavePlus),
cv.Optional(CONF_RADON): sensor.sensor_schema(
unit_of_measurement=UNIT_BECQUEREL_PER_CUBIC_METER,
icon=ICON_RADIOACTIVE,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_RADON_LONG_TERM): sensor.sensor_schema(
unit_of_measurement=UNIT_BECQUEREL_PER_CUBIC_METER,
icon=ICON_RADIOACTIVE,
accuracy_decimals=0,
state_class=STATE_CLASS_MEASUREMENT,
),
cv.Optional(CONF_CO2): sensor.sensor_schema(
unit_of_measurement=UNIT_PARTS_PER_MILLION,
accuracy_decimals=0,
device_class=DEVICE_CLASS_CARBON_DIOXIDE,
state_class=STATE_CLASS_MEASUREMENT,
),
}
)
async def to_code(config):
var = cg.new_Pvariable(config[CONF_ID])
await cg.register_component(var, config)
await airthings_wave_base.wave_base_to_code(var, config)
await ble_client.register_ble_node(var, config)
if CONF_HUMIDITY in config:
sens = await sensor.new_sensor(config[CONF_HUMIDITY])
cg.add(var.set_humidity(sens))
if CONF_RADON in config:
sens = await sensor.new_sensor(config[CONF_RADON])
cg.add(var.set_radon(sens))
if CONF_RADON_LONG_TERM in config:
sens = await sensor.new_sensor(config[CONF_RADON_LONG_TERM])
cg.add(var.set_radon_long_term(sens))
if CONF_TEMPERATURE in config:
sens = await sensor.new_sensor(config[CONF_TEMPERATURE])
cg.add(var.set_temperature(sens))
if CONF_PRESSURE in config:
sens = await sensor.new_sensor(config[CONF_PRESSURE])
cg.add(var.set_pressure(sens))
if CONF_CO2 in config:
sens = await sensor.new_sensor(config[CONF_CO2])
cg.add(var.set_co2(sens))
if CONF_TVOC in config:
sens = await sensor.new_sensor(config[CONF_TVOC])
cg.add(var.set_tvoc(sens))

View file

@ -312,7 +312,8 @@ sensor:
id: freezer_temp_source
reference_voltage: 3.19
number: 0
- platform: airthings_wave_plus
- id: airthingswp
platform: airthings_wave_plus
ble_client_id: airthings01
update_interval: 5min
temperature:
@ -329,7 +330,8 @@ sensor:
name: Wave Plus CO2
tvoc:
name: Wave Plus VOC
- platform: airthings_wave_mini
- id: airthingswm
platform: airthings_wave_mini
ble_client_id: airthingsmini01
update_interval: 5min
temperature: