mirror of
https://github.com/esphome/esphome.git
synced 2024-12-22 13:34:54 +01:00
Improve BME680 BSEC sensor device classes (#4859)
This commit is contained in:
parent
8bf8892ab3
commit
8ca9115dc8
1 changed files with 6 additions and 10 deletions
|
@ -6,8 +6,10 @@ from esphome.const import (
|
|||
CONF_HUMIDITY,
|
||||
CONF_PRESSURE,
|
||||
CONF_TEMPERATURE,
|
||||
DEVICE_CLASS_CARBON_DIOXIDE,
|
||||
DEVICE_CLASS_HUMIDITY,
|
||||
DEVICE_CLASS_PRESSURE,
|
||||
DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS_PARTS,
|
||||
DEVICE_CLASS_ATMOSPHERIC_PRESSURE,
|
||||
DEVICE_CLASS_TEMPERATURE,
|
||||
STATE_CLASS_MEASUREMENT,
|
||||
UNIT_CELSIUS,
|
||||
|
@ -17,8 +19,6 @@ from esphome.const import (
|
|||
UNIT_PERCENT,
|
||||
ICON_GAS_CYLINDER,
|
||||
ICON_GAUGE,
|
||||
ICON_THERMOMETER,
|
||||
ICON_WATER_PERCENT,
|
||||
)
|
||||
from . import (
|
||||
BME680BSECComponent,
|
||||
|
@ -35,7 +35,6 @@ CONF_CO2_EQUIVALENT = "co2_equivalent"
|
|||
CONF_BREATH_VOC_EQUIVALENT = "breath_voc_equivalent"
|
||||
UNIT_IAQ = "IAQ"
|
||||
ICON_ACCURACY = "mdi:checkbox-marked-circle-outline"
|
||||
ICON_TEST_TUBE = "mdi:test-tube"
|
||||
|
||||
TYPES = [
|
||||
CONF_TEMPERATURE,
|
||||
|
@ -53,7 +52,6 @@ CONFIG_SCHEMA = cv.Schema(
|
|||
cv.GenerateID(CONF_BME680_BSEC_ID): cv.use_id(BME680BSECComponent),
|
||||
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_CELSIUS,
|
||||
icon=ICON_THERMOMETER,
|
||||
accuracy_decimals=1,
|
||||
device_class=DEVICE_CLASS_TEMPERATURE,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
|
@ -62,16 +60,14 @@ CONFIG_SCHEMA = cv.Schema(
|
|||
),
|
||||
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_HECTOPASCAL,
|
||||
icon=ICON_GAUGE,
|
||||
accuracy_decimals=1,
|
||||
device_class=DEVICE_CLASS_PRESSURE,
|
||||
device_class=DEVICE_CLASS_ATMOSPHERIC_PRESSURE,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
).extend(
|
||||
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
|
||||
),
|
||||
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_PERCENT,
|
||||
icon=ICON_WATER_PERCENT,
|
||||
accuracy_decimals=1,
|
||||
device_class=DEVICE_CLASS_HUMIDITY,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
|
@ -97,14 +93,14 @@ CONFIG_SCHEMA = cv.Schema(
|
|||
),
|
||||
cv.Optional(CONF_CO2_EQUIVALENT): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_PARTS_PER_MILLION,
|
||||
icon=ICON_TEST_TUBE,
|
||||
accuracy_decimals=1,
|
||||
device_class=DEVICE_CLASS_CARBON_DIOXIDE,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
),
|
||||
cv.Optional(CONF_BREATH_VOC_EQUIVALENT): sensor.sensor_schema(
|
||||
unit_of_measurement=UNIT_PARTS_PER_MILLION,
|
||||
icon=ICON_TEST_TUBE,
|
||||
accuracy_decimals=1,
|
||||
device_class=DEVICE_CLASS_VOLATILE_ORGANIC_COMPOUNDS_PARTS,
|
||||
state_class=STATE_CLASS_MEASUREMENT,
|
||||
),
|
||||
}
|
||||
|
|
Loading…
Reference in a new issue