mirror of
https://github.com/esphome/esphome.git
synced 2024-12-21 21:14:52 +01:00
[haier] `text_sensor
and
button
` platforms (#6780)
This commit is contained in:
parent
4ab7a5d964
commit
aed0593793
23 changed files with 396 additions and 80 deletions
|
@ -152,6 +152,10 @@ esphome/components/grove_tb6612fng/* @max246
|
|||
esphome/components/growatt_solar/* @leeuwte
|
||||
esphome/components/gt911/* @clydebarrow @jesserockz
|
||||
esphome/components/haier/* @paveldn
|
||||
esphome/components/haier/binary_sensor/* @paveldn
|
||||
esphome/components/haier/button/* @paveldn
|
||||
esphome/components/haier/sensor/* @paveldn
|
||||
esphome/components/haier/text_sensor/* @paveldn
|
||||
esphome/components/havells_solar/* @sourabhjaiswal
|
||||
esphome/components/hbridge/fan/* @WeekendWarrior
|
||||
esphome/components/hbridge/light/* @DotNetDann
|
||||
|
|
|
@ -46,7 +46,7 @@ template<typename... Ts> class BeeperOffAction : public Action<Ts...> {
|
|||
template<typename... Ts> class VerticalAirflowAction : public Action<Ts...> {
|
||||
public:
|
||||
VerticalAirflowAction(HonClimate *parent) : parent_(parent) {}
|
||||
TEMPLATABLE_VALUE(AirflowVerticalDirection, direction)
|
||||
TEMPLATABLE_VALUE(hon_protocol::VerticalSwingMode, direction)
|
||||
void play(Ts... x) { this->parent_->set_vertical_airflow(this->direction_.value(x...)); }
|
||||
|
||||
protected:
|
||||
|
@ -56,7 +56,7 @@ template<typename... Ts> class VerticalAirflowAction : public Action<Ts...> {
|
|||
template<typename... Ts> class HorizontalAirflowAction : public Action<Ts...> {
|
||||
public:
|
||||
HorizontalAirflowAction(HonClimate *parent) : parent_(parent) {}
|
||||
TEMPLATABLE_VALUE(AirflowHorizontalDirection, direction)
|
||||
TEMPLATABLE_VALUE(hon_protocol::HorizontalSwingMode, direction)
|
||||
void play(Ts... x) { this->parent_->set_horizontal_airflow(this->direction_.value(x...)); }
|
||||
|
||||
protected:
|
||||
|
|
|
@ -11,6 +11,7 @@ from ..climate import (
|
|||
HonClimate,
|
||||
)
|
||||
|
||||
CODEOWNERS = ["@paveldn"]
|
||||
BinarySensorTypeEnum = HonClimate.enum("SubBinarySensorType", True)
|
||||
|
||||
# Haier sensors
|
||||
|
|
41
esphome/components/haier/button/__init__.py
Normal file
41
esphome/components/haier/button/__init__.py
Normal file
|
@ -0,0 +1,41 @@
|
|||
import esphome.codegen as cg
|
||||
import esphome.config_validation as cv
|
||||
from esphome.components import button
|
||||
from ..climate import (
|
||||
CONF_HAIER_ID,
|
||||
HonClimate,
|
||||
haier_ns,
|
||||
)
|
||||
|
||||
CODEOWNERS = ["@paveldn"]
|
||||
SelfCleaningButton = haier_ns.class_("SelfCleaningButton", button.Button)
|
||||
SteriCleaningButton = haier_ns.class_("SteriCleaningButton", button.Button)
|
||||
|
||||
|
||||
# Haier buttons
|
||||
CONF_SELF_CLEANING = "self_cleaning"
|
||||
CONF_STERI_CLEANING = "steri_cleaning"
|
||||
|
||||
# Additional icons
|
||||
ICON_SPRAY_BOTTLE = "mdi:spray-bottle"
|
||||
|
||||
CONFIG_SCHEMA = cv.Schema(
|
||||
{
|
||||
cv.Required(CONF_HAIER_ID): cv.use_id(HonClimate),
|
||||
cv.Optional(CONF_SELF_CLEANING): button.button_schema(
|
||||
SelfCleaningButton,
|
||||
icon=ICON_SPRAY_BOTTLE,
|
||||
),
|
||||
cv.Optional(CONF_STERI_CLEANING): button.button_schema(
|
||||
SteriCleaningButton,
|
||||
icon=ICON_SPRAY_BOTTLE,
|
||||
),
|
||||
}
|
||||
)
|
||||
|
||||
|
||||
async def to_code(config):
|
||||
for button_type in [CONF_SELF_CLEANING, CONF_STERI_CLEANING]:
|
||||
if conf := config.get(button_type):
|
||||
btn = await button.new_button(conf)
|
||||
await cg.register_parented(btn, config[CONF_HAIER_ID])
|
9
esphome/components/haier/button/self_cleaning.cpp
Normal file
9
esphome/components/haier/button/self_cleaning.cpp
Normal file
|
@ -0,0 +1,9 @@
|
|||
#include "self_cleaning.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace haier {
|
||||
|
||||
void SelfCleaningButton::press_action() { this->parent_->start_self_cleaning(); }
|
||||
|
||||
} // namespace haier
|
||||
} // namespace esphome
|
18
esphome/components/haier/button/self_cleaning.h
Normal file
18
esphome/components/haier/button/self_cleaning.h
Normal file
|
@ -0,0 +1,18 @@
|
|||
#pragma once
|
||||
|
||||
#include "esphome/components/button/button.h"
|
||||
#include "../hon_climate.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace haier {
|
||||
|
||||
class SelfCleaningButton : public button::Button, public Parented<HonClimate> {
|
||||
public:
|
||||
SelfCleaningButton() = default;
|
||||
|
||||
protected:
|
||||
void press_action() override;
|
||||
};
|
||||
|
||||
} // namespace haier
|
||||
} // namespace esphome
|
9
esphome/components/haier/button/steri_cleaning.cpp
Normal file
9
esphome/components/haier/button/steri_cleaning.cpp
Normal file
|
@ -0,0 +1,9 @@
|
|||
#include "steri_cleaning.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace haier {
|
||||
|
||||
void SteriCleaningButton::press_action() { this->parent_->start_steri_cleaning(); }
|
||||
|
||||
} // namespace haier
|
||||
} // namespace esphome
|
18
esphome/components/haier/button/steri_cleaning.h
Normal file
18
esphome/components/haier/button/steri_cleaning.h
Normal file
|
@ -0,0 +1,18 @@
|
|||
#pragma once
|
||||
|
||||
#include "esphome/components/button/button.h"
|
||||
#include "../hon_climate.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace haier {
|
||||
|
||||
class SteriCleaningButton : public button::Button, public Parented<HonClimate> {
|
||||
public:
|
||||
SteriCleaningButton() = default;
|
||||
|
||||
protected:
|
||||
void press_action() override;
|
||||
};
|
||||
|
||||
} // namespace haier
|
||||
} // namespace esphome
|
|
@ -55,6 +55,7 @@ PROTOCOL_HON = "HON"
|
|||
PROTOCOL_SMARTAIR2 = "SMARTAIR2"
|
||||
|
||||
haier_ns = cg.esphome_ns.namespace("haier")
|
||||
hon_protocol_ns = haier_ns.namespace("hon_protocol")
|
||||
HaierClimateBase = haier_ns.class_(
|
||||
"HaierClimateBase", uart.UARTDevice, climate.Climate, cg.Component
|
||||
)
|
||||
|
@ -63,7 +64,7 @@ Smartair2Climate = haier_ns.class_("Smartair2Climate", HaierClimateBase)
|
|||
|
||||
CONF_HAIER_ID = "haier_id"
|
||||
|
||||
AirflowVerticalDirection = haier_ns.enum("AirflowVerticalDirection", True)
|
||||
AirflowVerticalDirection = hon_protocol_ns.enum("VerticalSwingMode", True)
|
||||
AIRFLOW_VERTICAL_DIRECTION_OPTIONS = {
|
||||
"HEALTH_UP": AirflowVerticalDirection.HEALTH_UP,
|
||||
"MAX_UP": AirflowVerticalDirection.MAX_UP,
|
||||
|
@ -73,7 +74,7 @@ AIRFLOW_VERTICAL_DIRECTION_OPTIONS = {
|
|||
"HEALTH_DOWN": AirflowVerticalDirection.HEALTH_DOWN,
|
||||
}
|
||||
|
||||
AirflowHorizontalDirection = haier_ns.enum("AirflowHorizontalDirection", True)
|
||||
AirflowHorizontalDirection = hon_protocol_ns.enum("HorizontalSwingMode", True)
|
||||
AIRFLOW_HORIZONTAL_DIRECTION_OPTIONS = {
|
||||
"MAX_LEFT": AirflowHorizontalDirection.MAX_LEFT,
|
||||
"LEFT": AirflowHorizontalDirection.LEFT,
|
||||
|
@ -483,4 +484,4 @@ async def to_code(config):
|
|||
trigger, [(cg.uint8, "code"), (cg.const_char_ptr, "message")], conf
|
||||
)
|
||||
# https://github.com/paveldn/HaierProtocol
|
||||
cg.add_library("pavlodn/HaierProtocol", "0.9.25")
|
||||
cg.add_library("pavlodn/HaierProtocol", "0.9.28")
|
||||
|
|
|
@ -234,6 +234,7 @@ void HaierClimateBase::setup() {
|
|||
this->haier_protocol_.set_default_timeout_handler(
|
||||
std::bind(&esphome::haier::HaierClimateBase::timeout_default_handler_, this, std::placeholders::_1));
|
||||
this->set_handlers();
|
||||
this->initialization();
|
||||
}
|
||||
|
||||
void HaierClimateBase::dump_config() {
|
||||
|
@ -326,7 +327,7 @@ ClimateTraits HaierClimateBase::traits() { return traits_; }
|
|||
|
||||
void HaierClimateBase::control(const ClimateCall &call) {
|
||||
ESP_LOGD("Control", "Control call");
|
||||
if (this->protocol_phase_ < ProtocolPhases::IDLE) {
|
||||
if (!this->valid_connection()) {
|
||||
ESP_LOGW(TAG, "Can't send control packet, first poll answer not received");
|
||||
return; // cancel the control, we cant do it without a poll answer.
|
||||
}
|
||||
|
|
|
@ -44,7 +44,7 @@ class HaierClimateBase : public esphome::Component,
|
|||
void set_supported_modes(const std::set<esphome::climate::ClimateMode> &modes);
|
||||
void set_supported_swing_modes(const std::set<esphome::climate::ClimateSwingMode> &modes);
|
||||
void set_supported_presets(const std::set<esphome::climate::ClimatePreset> &presets);
|
||||
bool valid_connection() { return this->protocol_phase_ >= ProtocolPhases::IDLE; };
|
||||
bool valid_connection() const { return this->protocol_phase_ >= ProtocolPhases::IDLE; };
|
||||
size_t available() noexcept override { return esphome::uart::UARTDevice::available(); };
|
||||
size_t read_array(uint8_t *data, size_t len) noexcept override {
|
||||
return esphome::uart::UARTDevice::read_array(data, len) ? len : 0;
|
||||
|
@ -80,6 +80,7 @@ class HaierClimateBase : public esphome::Component,
|
|||
virtual void process_phase(std::chrono::steady_clock::time_point now) = 0;
|
||||
virtual haier_protocol::HaierMessage get_control_message() = 0;
|
||||
virtual haier_protocol::HaierMessage get_power_message(bool state) = 0;
|
||||
virtual void initialization(){};
|
||||
virtual bool prepare_pending_action();
|
||||
virtual void process_protocol_reset();
|
||||
esphome::climate::ClimateTraits traits() override;
|
||||
|
|
|
@ -19,38 +19,6 @@ constexpr uint8_t CONTROL_MESSAGE_RETRIES = 5;
|
|||
constexpr std::chrono::milliseconds CONTROL_MESSAGE_RETRIES_INTERVAL = std::chrono::milliseconds(500);
|
||||
constexpr size_t ALARM_STATUS_REQUEST_INTERVAL_MS = 600000;
|
||||
|
||||
hon_protocol::VerticalSwingMode get_vertical_swing_mode(AirflowVerticalDirection direction) {
|
||||
switch (direction) {
|
||||
case AirflowVerticalDirection::HEALTH_UP:
|
||||
return hon_protocol::VerticalSwingMode::HEALTH_UP;
|
||||
case AirflowVerticalDirection::MAX_UP:
|
||||
return hon_protocol::VerticalSwingMode::MAX_UP;
|
||||
case AirflowVerticalDirection::UP:
|
||||
return hon_protocol::VerticalSwingMode::UP;
|
||||
case AirflowVerticalDirection::DOWN:
|
||||
return hon_protocol::VerticalSwingMode::DOWN;
|
||||
case AirflowVerticalDirection::HEALTH_DOWN:
|
||||
return hon_protocol::VerticalSwingMode::HEALTH_DOWN;
|
||||
default:
|
||||
return hon_protocol::VerticalSwingMode::CENTER;
|
||||
}
|
||||
}
|
||||
|
||||
hon_protocol::HorizontalSwingMode get_horizontal_swing_mode(AirflowHorizontalDirection direction) {
|
||||
switch (direction) {
|
||||
case AirflowHorizontalDirection::MAX_LEFT:
|
||||
return hon_protocol::HorizontalSwingMode::MAX_LEFT;
|
||||
case AirflowHorizontalDirection::LEFT:
|
||||
return hon_protocol::HorizontalSwingMode::LEFT;
|
||||
case AirflowHorizontalDirection::RIGHT:
|
||||
return hon_protocol::HorizontalSwingMode::RIGHT;
|
||||
case AirflowHorizontalDirection::MAX_RIGHT:
|
||||
return hon_protocol::HorizontalSwingMode::MAX_RIGHT;
|
||||
default:
|
||||
return hon_protocol::HorizontalSwingMode::CENTER;
|
||||
}
|
||||
}
|
||||
|
||||
HonClimate::HonClimate()
|
||||
: cleaning_status_(CleaningState::NO_CLEANING), got_valid_outdoor_temp_(false), active_alarms_{0x00, 0x00, 0x00,
|
||||
0x00, 0x00, 0x00,
|
||||
|
@ -66,17 +34,21 @@ void HonClimate::set_beeper_state(bool state) { this->beeper_status_ = state; }
|
|||
|
||||
bool HonClimate::get_beeper_state() const { return this->beeper_status_; }
|
||||
|
||||
AirflowVerticalDirection HonClimate::get_vertical_airflow() const { return this->vertical_direction_; };
|
||||
esphome::optional<hon_protocol::VerticalSwingMode> HonClimate::get_vertical_airflow() const {
|
||||
return this->current_vertical_swing_;
|
||||
};
|
||||
|
||||
void HonClimate::set_vertical_airflow(AirflowVerticalDirection direction) {
|
||||
this->vertical_direction_ = direction;
|
||||
void HonClimate::set_vertical_airflow(hon_protocol::VerticalSwingMode direction) {
|
||||
this->pending_vertical_direction_ = direction;
|
||||
this->force_send_control_ = true;
|
||||
}
|
||||
|
||||
AirflowHorizontalDirection HonClimate::get_horizontal_airflow() const { return this->horizontal_direction_; }
|
||||
esphome::optional<hon_protocol::HorizontalSwingMode> HonClimate::get_horizontal_airflow() const {
|
||||
return this->current_horizontal_swing_;
|
||||
}
|
||||
|
||||
void HonClimate::set_horizontal_airflow(AirflowHorizontalDirection direction) {
|
||||
this->horizontal_direction_ = direction;
|
||||
void HonClimate::set_horizontal_airflow(hon_protocol::HorizontalSwingMode direction) {
|
||||
this->pending_horizontal_direction_ = direction;
|
||||
this->force_send_control_ = true;
|
||||
}
|
||||
|
||||
|
@ -148,6 +120,11 @@ haier_protocol::HandlerError HonClimate::get_device_version_answer_handler_(haie
|
|||
this->hvac_hardware_info_.value().hardware_version_ = std::string(tmp);
|
||||
strncpy(tmp, answr->device_name, 8);
|
||||
this->hvac_hardware_info_.value().device_name_ = std::string(tmp);
|
||||
#ifdef USE_TEXT_SENSOR
|
||||
this->update_sub_text_sensor_(SubTextSensorType::APPLIANCE_NAME, this->hvac_hardware_info_.value().device_name_);
|
||||
this->update_sub_text_sensor_(SubTextSensorType::PROTOCOL_VERSION,
|
||||
this->hvac_hardware_info_.value().protocol_version_);
|
||||
#endif
|
||||
this->hvac_hardware_info_.value().functions_[0] = (answr->functions[1] & 0x01) != 0; // interactive mode support
|
||||
this->hvac_hardware_info_.value().functions_[1] =
|
||||
(answr->functions[1] & 0x02) != 0; // controller-device mode support
|
||||
|
@ -488,6 +465,19 @@ haier_protocol::HaierMessage HonClimate::get_power_message(bool state) {
|
|||
}
|
||||
}
|
||||
|
||||
void HonClimate::initialization() {
|
||||
constexpr uint32_t restore_settings_version = 0xE834D8DCUL;
|
||||
this->rtc_ = global_preferences->make_preference<HonSettings>(this->get_object_id_hash() ^ restore_settings_version);
|
||||
HonSettings recovered;
|
||||
if (this->rtc_.load(&recovered)) {
|
||||
this->settings_ = recovered;
|
||||
} else {
|
||||
this->settings_ = {hon_protocol::VerticalSwingMode::CENTER, hon_protocol::HorizontalSwingMode::CENTER};
|
||||
}
|
||||
this->current_vertical_swing_ = this->settings_.last_vertiacal_swing;
|
||||
this->current_horizontal_swing_ = this->settings_.last_horizontal_swing;
|
||||
}
|
||||
|
||||
haier_protocol::HaierMessage HonClimate::get_control_message() {
|
||||
uint8_t control_out_buffer[sizeof(hon_protocol::HaierPacketControl)];
|
||||
memcpy(control_out_buffer, this->last_status_message_.get(), sizeof(hon_protocol::HaierPacketControl));
|
||||
|
@ -560,16 +550,16 @@ haier_protocol::HaierMessage HonClimate::get_control_message() {
|
|||
if (climate_control.swing_mode.has_value()) {
|
||||
switch (climate_control.swing_mode.value()) {
|
||||
case CLIMATE_SWING_OFF:
|
||||
out_data->horizontal_swing_mode = (uint8_t) get_horizontal_swing_mode(this->horizontal_direction_);
|
||||
out_data->vertical_swing_mode = (uint8_t) get_vertical_swing_mode(this->vertical_direction_);
|
||||
out_data->horizontal_swing_mode = (uint8_t) this->settings_.last_horizontal_swing;
|
||||
out_data->vertical_swing_mode = (uint8_t) this->settings_.last_vertiacal_swing;
|
||||
break;
|
||||
case CLIMATE_SWING_VERTICAL:
|
||||
out_data->horizontal_swing_mode = (uint8_t) get_horizontal_swing_mode(this->horizontal_direction_);
|
||||
out_data->horizontal_swing_mode = (uint8_t) this->settings_.last_horizontal_swing;
|
||||
out_data->vertical_swing_mode = (uint8_t) hon_protocol::VerticalSwingMode::AUTO;
|
||||
break;
|
||||
case CLIMATE_SWING_HORIZONTAL:
|
||||
out_data->horizontal_swing_mode = (uint8_t) hon_protocol::HorizontalSwingMode::AUTO;
|
||||
out_data->vertical_swing_mode = (uint8_t) get_vertical_swing_mode(this->vertical_direction_);
|
||||
out_data->vertical_swing_mode = (uint8_t) this->settings_.last_vertiacal_swing;
|
||||
break;
|
||||
case CLIMATE_SWING_BOTH:
|
||||
out_data->horizontal_swing_mode = (uint8_t) hon_protocol::HorizontalSwingMode::AUTO;
|
||||
|
@ -631,11 +621,14 @@ haier_protocol::HaierMessage HonClimate::get_control_message() {
|
|||
break;
|
||||
}
|
||||
}
|
||||
} else {
|
||||
if (out_data->vertical_swing_mode != (uint8_t) hon_protocol::VerticalSwingMode::AUTO)
|
||||
out_data->vertical_swing_mode = (uint8_t) get_vertical_swing_mode(this->vertical_direction_);
|
||||
if (out_data->horizontal_swing_mode != (uint8_t) hon_protocol::HorizontalSwingMode::AUTO)
|
||||
out_data->horizontal_swing_mode = (uint8_t) get_horizontal_swing_mode(this->horizontal_direction_);
|
||||
}
|
||||
if (this->pending_vertical_direction_.has_value()) {
|
||||
out_data->vertical_swing_mode = (uint8_t) this->pending_vertical_direction_.value();
|
||||
this->pending_vertical_direction_.reset();
|
||||
}
|
||||
if (this->pending_horizontal_direction_.has_value()) {
|
||||
out_data->horizontal_swing_mode = (uint8_t) this->pending_horizontal_direction_.value();
|
||||
this->pending_horizontal_direction_.reset();
|
||||
}
|
||||
out_data->beeper_status = ((!this->beeper_status_) || (!has_hvac_settings)) ? 1 : 0;
|
||||
control_out_buffer[4] = 0; // This byte should be cleared before setting values
|
||||
|
@ -737,6 +730,33 @@ void HonClimate::update_sub_binary_sensor_(SubBinarySensorType type, uint8_t val
|
|||
}
|
||||
#endif // USE_BINARY_SENSOR
|
||||
|
||||
#ifdef USE_TEXT_SENSOR
|
||||
void HonClimate::set_sub_text_sensor(SubTextSensorType type, text_sensor::TextSensor *sens) {
|
||||
this->sub_text_sensors_[(size_t) type] = sens;
|
||||
switch (type) {
|
||||
case SubTextSensorType::APPLIANCE_NAME:
|
||||
if (this->hvac_hardware_info_.has_value())
|
||||
sens->publish_state(this->hvac_hardware_info_.value().device_name_);
|
||||
break;
|
||||
case SubTextSensorType::PROTOCOL_VERSION:
|
||||
if (this->hvac_hardware_info_.has_value())
|
||||
sens->publish_state(this->hvac_hardware_info_.value().protocol_version_);
|
||||
break;
|
||||
case SubTextSensorType::CLEANING_STATUS:
|
||||
sens->publish_state(this->get_cleaning_status_text());
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
}
|
||||
|
||||
void HonClimate::update_sub_text_sensor_(SubTextSensorType type, const std::string &value) {
|
||||
size_t index = (size_t) type;
|
||||
if (this->sub_text_sensors_[index] != nullptr)
|
||||
this->sub_text_sensors_[index]->publish_state(value);
|
||||
}
|
||||
#endif // USE_TEXT_SENSOR
|
||||
|
||||
haier_protocol::HandlerError HonClimate::process_status_message_(const uint8_t *packet_buffer, uint8_t size) {
|
||||
size_t expected_size = 2 + sizeof(hon_protocol::HaierPacketControl) + sizeof(hon_protocol::HaierPacketSensors) +
|
||||
this->extra_control_packet_bytes_;
|
||||
|
@ -896,6 +916,9 @@ haier_protocol::HandlerError HonClimate::process_status_message_(const uint8_t *
|
|||
PendingAction({ActionRequest::TURN_POWER_OFF, esphome::optional<haier_protocol::HaierMessage>()});
|
||||
}
|
||||
this->cleaning_status_ = new_cleaning;
|
||||
#ifdef USE_TEXT_SENSOR
|
||||
this->update_sub_text_sensor_(SubTextSensorType::CLEANING_STATUS, this->get_cleaning_status_text());
|
||||
#endif // USE_TEXT_SENSOR
|
||||
}
|
||||
}
|
||||
{
|
||||
|
@ -941,6 +964,19 @@ haier_protocol::HandlerError HonClimate::process_status_message_(const uint8_t *
|
|||
this->swing_mode = CLIMATE_SWING_OFF;
|
||||
}
|
||||
}
|
||||
// Saving last known non auto mode for vertical and horizontal swing
|
||||
this->current_vertical_swing_ = (hon_protocol::VerticalSwingMode) packet.control.vertical_swing_mode;
|
||||
this->current_horizontal_swing_ = (hon_protocol::HorizontalSwingMode) packet.control.horizontal_swing_mode;
|
||||
bool save_settings = ((this->current_vertical_swing_.value() != hon_protocol::VerticalSwingMode::AUTO) &&
|
||||
(this->current_vertical_swing_.value() != hon_protocol::VerticalSwingMode::AUTO_SPECIAL) &&
|
||||
(this->current_vertical_swing_.value() != this->settings_.last_vertiacal_swing)) ||
|
||||
((this->current_horizontal_swing_.value() != hon_protocol::HorizontalSwingMode::AUTO) &&
|
||||
(this->current_horizontal_swing_.value() != this->settings_.last_horizontal_swing));
|
||||
if (save_settings) {
|
||||
this->settings_.last_vertiacal_swing = this->current_vertical_swing_.value();
|
||||
this->settings_.last_horizontal_swing = this->current_horizontal_swing_.value();
|
||||
this->rtc_.save(&this->settings_);
|
||||
}
|
||||
should_publish = should_publish || (old_swing_mode != this->swing_mode);
|
||||
}
|
||||
this->last_valid_status_timestamp_ = std::chrono::steady_clock::now();
|
||||
|
|
|
@ -7,29 +7,16 @@
|
|||
#ifdef USE_BINARY_SENSOR
|
||||
#include "esphome/components/binary_sensor/binary_sensor.h"
|
||||
#endif
|
||||
#ifdef USE_TEXT_SENSOR
|
||||
#include "esphome/components/text_sensor/text_sensor.h"
|
||||
#endif
|
||||
#include "esphome/core/automation.h"
|
||||
#include "haier_base.h"
|
||||
#include "hon_packet.h"
|
||||
|
||||
namespace esphome {
|
||||
namespace haier {
|
||||
|
||||
enum class AirflowVerticalDirection : uint8_t {
|
||||
HEALTH_UP = 0,
|
||||
MAX_UP = 1,
|
||||
UP = 2,
|
||||
CENTER = 3,
|
||||
DOWN = 4,
|
||||
HEALTH_DOWN = 5,
|
||||
};
|
||||
|
||||
enum class AirflowHorizontalDirection : uint8_t {
|
||||
MAX_LEFT = 0,
|
||||
LEFT = 1,
|
||||
CENTER = 2,
|
||||
RIGHT = 3,
|
||||
MAX_RIGHT = 4,
|
||||
};
|
||||
|
||||
enum class CleaningState : uint8_t {
|
||||
NO_CLEANING = 0,
|
||||
SELF_CLEAN = 1,
|
||||
|
@ -38,6 +25,11 @@ enum class CleaningState : uint8_t {
|
|||
|
||||
enum class HonControlMethod { MONITOR_ONLY = 0, SET_GROUP_PARAMETERS, SET_SINGLE_PARAMETER };
|
||||
|
||||
struct HonSettings {
|
||||
hon_protocol::VerticalSwingMode last_vertiacal_swing;
|
||||
hon_protocol::HorizontalSwingMode last_horizontal_swing;
|
||||
};
|
||||
|
||||
class HonClimate : public HaierClimateBase {
|
||||
#ifdef USE_SENSOR
|
||||
public:
|
||||
|
@ -80,6 +72,20 @@ class HonClimate : public HaierClimateBase {
|
|||
protected:
|
||||
void update_sub_binary_sensor_(SubBinarySensorType type, uint8_t value);
|
||||
binary_sensor::BinarySensor *sub_binary_sensors_[(size_t) SubBinarySensorType::SUB_BINARY_SENSOR_TYPE_COUNT]{nullptr};
|
||||
#endif
|
||||
#ifdef USE_TEXT_SENSOR
|
||||
public:
|
||||
enum class SubTextSensorType {
|
||||
CLEANING_STATUS = 0,
|
||||
PROTOCOL_VERSION,
|
||||
APPLIANCE_NAME,
|
||||
SUB_TEXT_SENSOR_TYPE_COUNT,
|
||||
};
|
||||
void set_sub_text_sensor(SubTextSensorType type, text_sensor::TextSensor *sens);
|
||||
|
||||
protected:
|
||||
void update_sub_text_sensor_(SubTextSensorType type, const std::string &value);
|
||||
text_sensor::TextSensor *sub_text_sensors_[(size_t) SubTextSensorType::SUB_TEXT_SENSOR_TYPE_COUNT]{nullptr};
|
||||
#endif
|
||||
public:
|
||||
HonClimate();
|
||||
|
@ -89,10 +95,10 @@ class HonClimate : public HaierClimateBase {
|
|||
void dump_config() override;
|
||||
void set_beeper_state(bool state);
|
||||
bool get_beeper_state() const;
|
||||
AirflowVerticalDirection get_vertical_airflow() const;
|
||||
void set_vertical_airflow(AirflowVerticalDirection direction);
|
||||
AirflowHorizontalDirection get_horizontal_airflow() const;
|
||||
void set_horizontal_airflow(AirflowHorizontalDirection direction);
|
||||
esphome::optional<hon_protocol::VerticalSwingMode> get_vertical_airflow() const;
|
||||
void set_vertical_airflow(hon_protocol::VerticalSwingMode direction);
|
||||
esphome::optional<hon_protocol::HorizontalSwingMode> get_horizontal_airflow() const;
|
||||
void set_horizontal_airflow(hon_protocol::HorizontalSwingMode direction);
|
||||
std::string get_cleaning_status_text() const;
|
||||
CleaningState get_cleaning_status() const;
|
||||
void start_self_cleaning();
|
||||
|
@ -108,6 +114,7 @@ class HonClimate : public HaierClimateBase {
|
|||
void process_phase(std::chrono::steady_clock::time_point now) override;
|
||||
haier_protocol::HaierMessage get_control_message() override;
|
||||
haier_protocol::HaierMessage get_power_message(bool state) override;
|
||||
void initialization() override;
|
||||
bool prepare_pending_action() override;
|
||||
void process_protocol_reset() override;
|
||||
bool should_get_big_data_();
|
||||
|
@ -147,9 +154,9 @@ class HonClimate : public HaierClimateBase {
|
|||
bool beeper_status_;
|
||||
CleaningState cleaning_status_;
|
||||
bool got_valid_outdoor_temp_;
|
||||
AirflowVerticalDirection vertical_direction_;
|
||||
AirflowHorizontalDirection horizontal_direction_;
|
||||
esphome::optional<HardwareInfo> hvac_hardware_info_;
|
||||
esphome::optional<hon_protocol::VerticalSwingMode> pending_vertical_direction_{};
|
||||
esphome::optional<hon_protocol::HorizontalSwingMode> pending_horizontal_direction_{};
|
||||
esphome::optional<HardwareInfo> hvac_hardware_info_{};
|
||||
uint8_t active_alarms_[8];
|
||||
int extra_control_packet_bytes_;
|
||||
HonControlMethod control_method_;
|
||||
|
@ -159,6 +166,10 @@ class HonClimate : public HaierClimateBase {
|
|||
float active_alarm_count_{NAN};
|
||||
std::chrono::steady_clock::time_point last_alarm_request_;
|
||||
int big_data_sensors_{0};
|
||||
esphome::optional<hon_protocol::VerticalSwingMode> current_vertical_swing_{};
|
||||
esphome::optional<hon_protocol::HorizontalSwingMode> current_horizontal_swing_{};
|
||||
HonSettings settings_;
|
||||
ESPPreferenceObject rtc_;
|
||||
};
|
||||
|
||||
class HaierAlarmStartTrigger : public Trigger<uint8_t, const char *> {
|
||||
|
|
|
@ -13,7 +13,10 @@ enum class VerticalSwingMode : uint8_t {
|
|||
UP = 0x04,
|
||||
CENTER = 0x06,
|
||||
DOWN = 0x08,
|
||||
AUTO = 0x0C
|
||||
MAX_DOWN = 0x0A,
|
||||
AUTO = 0x0C,
|
||||
// Auto for special modes
|
||||
AUTO_SPECIAL = 0x0E
|
||||
};
|
||||
|
||||
enum class HorizontalSwingMode : uint8_t {
|
||||
|
|
|
@ -31,6 +31,7 @@ from ..climate import (
|
|||
HonClimate,
|
||||
)
|
||||
|
||||
CODEOWNERS = ["@paveldn"]
|
||||
SensorTypeEnum = HonClimate.enum("SubSensorType", True)
|
||||
|
||||
# Haier sensors
|
||||
|
|
54
esphome/components/haier/text_sensor/__init__.py
Normal file
54
esphome/components/haier/text_sensor/__init__.py
Normal file
|
@ -0,0 +1,54 @@
|
|||
import esphome.codegen as cg
|
||||
import esphome.config_validation as cv
|
||||
from esphome.components import text_sensor
|
||||
from esphome.const import (
|
||||
ENTITY_CATEGORY_DIAGNOSTIC,
|
||||
ENTITY_CATEGORY_NONE,
|
||||
)
|
||||
from ..climate import (
|
||||
CONF_HAIER_ID,
|
||||
HonClimate,
|
||||
)
|
||||
|
||||
CODEOWNERS = ["@paveldn"]
|
||||
TextSensorTypeEnum = HonClimate.enum("SubTextSensorType", True)
|
||||
|
||||
# Haier text sensors
|
||||
CONF_CLEANING_STATUS = "cleaning_status"
|
||||
CONF_PROTOCOL_VERSION = "protocol_version"
|
||||
CONF_APPLIANCE_NAME = "appliance_name"
|
||||
|
||||
# Additional icons
|
||||
ICON_SPRAY_BOTTLE = "mdi:spray-bottle"
|
||||
ICON_TEXT_BOX = "mdi:text-box-outline"
|
||||
|
||||
TEXT_SENSOR_TYPES = {
|
||||
CONF_CLEANING_STATUS: text_sensor.text_sensor_schema(
|
||||
icon=ICON_SPRAY_BOTTLE,
|
||||
entity_category=ENTITY_CATEGORY_NONE,
|
||||
),
|
||||
CONF_PROTOCOL_VERSION: text_sensor.text_sensor_schema(
|
||||
icon=ICON_TEXT_BOX,
|
||||
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
|
||||
),
|
||||
CONF_APPLIANCE_NAME: text_sensor.text_sensor_schema(
|
||||
icon=ICON_TEXT_BOX,
|
||||
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
|
||||
),
|
||||
}
|
||||
|
||||
CONFIG_SCHEMA = cv.Schema(
|
||||
{
|
||||
cv.Required(CONF_HAIER_ID): cv.use_id(HonClimate),
|
||||
}
|
||||
).extend({cv.Optional(type): schema for type, schema in TEXT_SENSOR_TYPES.items()})
|
||||
|
||||
|
||||
async def to_code(config):
|
||||
paren = await cg.get_variable(config[CONF_HAIER_ID])
|
||||
|
||||
for type, _ in TEXT_SENSOR_TYPES.items():
|
||||
if conf := config.get(type):
|
||||
sens = await text_sensor.new_text_sensor(conf)
|
||||
text_sensor_type = getattr(TextSensorTypeEnum, type.upper())
|
||||
cg.add(paren.set_sub_text_sensor(text_sensor_type, sens))
|
|
@ -39,7 +39,7 @@ lib_deps =
|
|||
bblanchon/ArduinoJson@6.18.5 ; json
|
||||
wjtje/qr-code-generator-library@1.7.0 ; qr_code
|
||||
functionpointer/arduino-MLX90393@1.0.0 ; mlx90393
|
||||
pavlodn/HaierProtocol@0.9.25 ; haier
|
||||
pavlodn/HaierProtocol@0.9.28 ; haier
|
||||
; This is using the repository until a new release is published to PlatformIO
|
||||
https://github.com/Sensirion/arduino-gas-index-algorithm.git#3.2.1 ; Sensirion Gas Index Algorithm Arduino Library
|
||||
build_flags =
|
||||
|
|
|
@ -93,3 +93,21 @@ binary_sensor:
|
|||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
|
|
|
@ -93,3 +93,21 @@ binary_sensor:
|
|||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
|
|
|
@ -93,3 +93,21 @@ binary_sensor:
|
|||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
|
|
|
@ -93,3 +93,21 @@ binary_sensor:
|
|||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
|
|
|
@ -93,3 +93,21 @@ binary_sensor:
|
|||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
|
|
|
@ -93,3 +93,21 @@ binary_sensor:
|
|||
name: Haier Indoor Fan Status
|
||||
outdoor_fan_status:
|
||||
name: Haier Outdoor Fan Status
|
||||
|
||||
button:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
self_cleaning:
|
||||
name: Haier start self cleaning
|
||||
steri_cleaning:
|
||||
name: Haier start 56°C steri-cleaning
|
||||
|
||||
text_sensor:
|
||||
- platform: haier
|
||||
haier_id: haier_ac
|
||||
appliance_name:
|
||||
name: Haier appliance name
|
||||
cleaning_status:
|
||||
name: Haier cleaning status
|
||||
protocol_version:
|
||||
name: Haier protocol version
|
||||
|
|
Loading…
Reference in a new issue