Pulse counter validate not both disabled (#902)

This commit is contained in:
Otto Winter 2019-12-04 15:59:27 +01:00 committed by GitHub
parent d26cd85306
commit e86f2e993f
No known key found for this signature in database
GPG key ID: 4AEE18F83AFDEB23

View file

@ -38,16 +38,25 @@ def validate_pulse_counter_pin(value):
return value
def validate_count_mode(value):
rising_edge = value[CONF_RISING_EDGE]
falling_edge = value[CONF_FALLING_EDGE]
if rising_edge == 'DISABLE' and falling_edge == 'DISABLE':
raise cv.Invalid("Can't set both count modes to DISABLE! This means no counting occurs at "
"all!")
return value
CONFIG_SCHEMA = sensor.sensor_schema(UNIT_PULSES_PER_MINUTE, ICON_PULSE, 2).extend({
cv.GenerateID(): cv.declare_id(PulseCounterSensor),
cv.Required(CONF_PIN): validate_pulse_counter_pin,
cv.Optional(CONF_COUNT_MODE, default={
CONF_RISING_EDGE: 'INCREMENT',
CONF_FALLING_EDGE: 'DISABLE',
}): cv.Schema({
}): cv.All(cv.Schema({
cv.Required(CONF_RISING_EDGE): COUNT_MODE_SCHEMA,
cv.Required(CONF_FALLING_EDGE): COUNT_MODE_SCHEMA,
}),
}), validate_count_mode),
cv.Optional(CONF_INTERNAL_FILTER, default='13us'): validate_internal_filter,
}).extend(cv.polling_component_schema('60s'))