@ -18,8 +18,8 @@ void ThermostatClimate::setup() {
|
|||
// add a callback so that whenever the sensor state changes we can take action
|
||||
this->sensor_->add_on_state_callback([this](float state) {
|
||||
this->current_temperature = state;
|
||||
// required action may have changed, recompute, refresh
|
||||
this->switch_to_action_(this->compute_action_());
|
||||
// required action may have changed, recompute, refresh, we'll publish_state() later
|
||||
this->switch_to_action_(this->compute_action_(), false);
|
||||
this->switch_to_supplemental_action_(this->compute_supplemental_action_());
|
||||
// current temperature and possibly action changed, so publish the new state
|
||||
this->publish_state();
|
||||
|
@ -34,8 +34,8 @@ void ThermostatClimate::setup() {
|
|||
this->mode = this->default_mode_;
|
||||
this->change_away_(false);
|
||||
}
|
||||
// refresh the climate action based on the restored settings
|
||||
this->switch_to_action_(this->compute_action_());
|
||||
// refresh the climate action based on the restored settings, we'll publish_state() later
|
||||
this->switch_to_action_(this->compute_action_(), false);
|
||||
this->switch_to_supplemental_action_(this->compute_supplemental_action_());
|
||||
this->setup_complete_ = true;
|
||||
this->publish_state();
|
||||
|
@ -47,11 +47,11 @@ float ThermostatClimate::heat_deadband() { return this->heating_deadband_; }
|
|||
float ThermostatClimate::heat_overrun() { return this->heating_overrun_; }
|
||||
|
||||
void ThermostatClimate::refresh() {
|
||||
this->switch_to_mode_(this->mode);
|
||||
this->switch_to_action_(this->compute_action_());
|
||||
this->switch_to_mode_(this->mode, false);
|
||||
this->switch_to_action_(this->compute_action_(), false);
|
||||
this->switch_to_supplemental_action_(this->compute_supplemental_action_());
|
||||
this->switch_to_fan_mode_(this->fan_mode.value());
|
||||
this->switch_to_swing_mode_(this->swing_mode);
|
||||
this->switch_to_fan_mode_(this->fan_mode.value(), false);
|
||||
this->switch_to_swing_mode_(this->swing_mode, false);
|
||||
this->check_temperature_change_trigger_();
|
||||
this->publish_state();
|
||||
}
|
||||
|
@ -346,7 +346,7 @@ climate::ClimateAction ThermostatClimate::compute_supplemental_action_() {
|
|||
return target_action;
|
||||
}
|
||||
|
||||
void ThermostatClimate::switch_to_action_(climate::ClimateAction action) {
|
||||
void ThermostatClimate::switch_to_action_(climate::ClimateAction action, bool publish_state) {
|
||||
// setup_complete_ helps us ensure an action is called immediately after boot
|
||||
if ((action == this->action) && this->setup_complete_)
|
||||
// already in target mode
|
||||
|
@ -358,6 +358,8 @@ void ThermostatClimate::switch_to_action_(climate::ClimateAction action) {
|
|||
// switching from OFF to IDLE or vice-versa -- this is only a visual difference.
|
||||
// OFF means user manually disabled, IDLE means the temperature is in target range.
|
||||
this->action = action;
|
||||
if (publish_state)
|
||||
this->publish_state();
|
||||
return;
|
||||
}
|
||||
|
||||
|
@ -452,6 +454,8 @@ void ThermostatClimate::switch_to_action_(climate::ClimateAction action) {
|
|||
ESP_LOGVV(TAG, "Calling FAN_ONLY action with HEATING/COOLING action");
|
||||
trig_fan->trigger();
|
||||
}
|
||||
if (publish_state)
|
||||
this->publish_state();
|
||||
}
|
||||
}
|
||||
|
||||
|
@ -509,13 +513,15 @@ void ThermostatClimate::trigger_supplemental_action_() {
|
|||
}
|
||||
}
|
||||
|
||||
void ThermostatClimate::switch_to_fan_mode_(climate::ClimateFanMode fan_mode) {
|
||||
void ThermostatClimate::switch_to_fan_mode_(climate::ClimateFanMode fan_mode, bool publish_state) {
|
||||
// setup_complete_ helps us ensure an action is called immediately after boot
|
||||
if ((fan_mode == this->prev_fan_mode_) && this->setup_complete_)
|
||||
// already in target mode
|
||||
return;
|
||||
|
||||
this->fan_mode = fan_mode;
|
||||
if (publish_state)
|
||||
this->publish_state();
|
||||
|
||||
if (this->fan_mode_ready_()) {
|
||||
Trigger<> *trig = this->fan_mode_auto_trigger_;
|
||||
|
@ -574,7 +580,7 @@ void ThermostatClimate::switch_to_fan_mode_(climate::ClimateFanMode fan_mode) {
|
|||
}
|
||||
}
|
||||
|
||||
void ThermostatClimate::switch_to_mode_(climate::ClimateMode mode) {
|
||||
void ThermostatClimate::switch_to_mode_(climate::ClimateMode mode, bool publish_state) {
|
||||
// setup_complete_ helps us ensure an action is called immediately after boot
|
||||
if ((mode == this->prev_mode_) && this->setup_complete_)
|
||||
// already in target mode
|
||||
|
@ -615,9 +621,11 @@ void ThermostatClimate::switch_to_mode_(climate::ClimateMode mode) {
|
|||
this->mode = mode;
|
||||
this->prev_mode_ = mode;
|
||||
this->prev_mode_trigger_ = trig;
|
||||
if (publish_state)
|
||||
this->publish_state();
|
||||
}
|
||||
|
||||
void ThermostatClimate::switch_to_swing_mode_(climate::ClimateSwingMode swing_mode) {
|
||||
void ThermostatClimate::switch_to_swing_mode_(climate::ClimateSwingMode swing_mode, bool publish_state) {
|
||||
// setup_complete_ helps us ensure an action is called immediately after boot
|
||||
if ((swing_mode == this->prev_swing_mode_) && this->setup_complete_)
|
||||
// already in target mode
|
||||
|
@ -652,6 +660,8 @@ void ThermostatClimate::switch_to_swing_mode_(climate::ClimateSwingMode swing_mo
|
|||
this->swing_mode = swing_mode;
|
||||
this->prev_swing_mode_ = swing_mode;
|
||||
this->prev_swing_mode_trigger_ = trig;
|
||||
if (publish_state)
|
||||
this->publish_state();
|
||||
}
|
||||
|
||||
bool ThermostatClimate::idle_action_ready_() {
|
||||
|
|
|
@ -160,18 +160,18 @@ class ThermostatClimate : public climate::Climate, public Component {
|
|||
climate::ClimateAction compute_supplemental_action_();
|
||||
|
||||
/// Switch the climate device to the given climate action.
|
||||
void switch_to_action_(climate::ClimateAction action);
|
||||
void switch_to_action_(climate::ClimateAction action, bool publish_state = true);
|
||||
void switch_to_supplemental_action_(climate::ClimateAction action);
|
||||
void trigger_supplemental_action_();
|
||||
|
||||
/// Switch the climate device to the given climate fan mode.
|
||||
void switch_to_fan_mode_(climate::ClimateFanMode fan_mode);
|
||||
void switch_to_fan_mode_(climate::ClimateFanMode fan_mode, bool publish_state = true);
|
||||
|
||||
/// Switch the climate device to the given climate mode.
|
||||
void switch_to_mode_(climate::ClimateMode mode);
|
||||
void switch_to_mode_(climate::ClimateMode mode, bool publish_state = true);
|
||||
|
||||
/// Switch the climate device to the given climate swing mode.
|
||||
void switch_to_swing_mode_(climate::ClimateSwingMode swing_mode);
|
||||
void switch_to_swing_mode_(climate::ClimateSwingMode swing_mode, bool publish_state = true);
|
||||
|
||||
/// Check if the temperature change trigger should be called.
|
||||
void check_temperature_change_trigger_();
|
||||
|
|
Loading…