* Add QMC5883L and Updated HMC5883L
* add tests
* changed to oversampling
* fix pylint
* fix private method
* typo fix
* fix protected method
* Clean up code and PR recomendations
* fix tests
* remote file
* fix qmc oversampling unit
* Remove hmc5883l config logging
Either the units are converted to the user values like 1x, 8x oversampling or not printed at all. Printing the machine-value of these is only confusing users.
* Changes for validate_enum
Move stuff that can be done beforehand out of the bound function, use text_type for py2/3 compatability.
* Remove unused constant
* Remove duplicate tests
* Repeat remove config print
* remove changes to test2 since bin is to large
* Add comment to HMC5583L
Co-authored-by: Timothy Purchas <timothy@TPF.local>
Co-authored-by: Otto Winter <otto@otto-winter.com>
In a heavy EMI environment, reading the current config from the MAX31865 can
fail, such as switching from a 4-wire sensor to a 3-wire sensor. This causes
the temperature value to be off wildly, but still technically valid, so it
doesn't get reported as a sensor failure.
Since we know what configuration we want, rather than send it to the MAX31865
on setup and ask for it over and over (propagating any error as we write it
back), instead store the base configuration and work from that to change modes.
This not only avoids propagating any error, it also saves a lot of unnecessary
reads from the MAX31865.
* added idle
* more clear state description
* Also add drying/fan
Putting it in this PR because it will be put in the same aioesphomeapi release anyway.
* Update bang_bang for idle action
Co-authored-by: root <root@mail.danman.eu>
Co-authored-by: Otto Winter <otto@otto-winter.com>
* Added more data to atm90e32 component
* ignore
* correction
* Delete 6chan_energy_meter.yaml
* PR request changes
* repository test branch
* Update setup.py
* Update const.py
* delete test yaml
* fix chip_temperature_sensor
This was throwing an error if chip_temperature was used. It needed to be changed from temp to temperature.
* default
* Update test1.yaml
* Decode DHT11 decimal part
* Fix comment
* Fix comment
* Handle negative temp for some DHT11 - code from the DHT12 component
* Don't use the fractional part if the checksum is the 2 bytes one
* Fix logger uart conflict check
* Fix class for check func
* Fix syntax
Hope lint is OK with moving the end of the conditional outside the #IFDEF
* Move end of conditional inside ifdef and remove extra whitespace
* Simplify
clang-format did not like the ifdefs and was reformatting in a way that killed clang-tidy.
Simple solution is to use logger's hw_serial as source of truth
Also simplifies the code - uart doesn't need to know what the logger uart settings mean
* Add api missing_state attribute
Fixes https://github.com/esphome/issues/issues/828
Adds a new property for missing state, so that HA can now when a sensor does not have a state yet.
* Update api.proto
* implemented ruuvi_ble and ruuvitag with RAWv1 protocol
fixesesphome/feature-requests#313
* lint
* updated data calculations
* cpp lint
* use string directly in message
Co-Authored-By: Otto Winter <otto@otto-winter.com>
* add RAWv2 protocol support
* fix ICON_SIGNAL
* typo
* calculation correction and cleaning
* c++ lint
* added acceleration and fixed typo
* removed remote_receiver to reduce firmware size
remote_receiver also in test1.yaml
* Add MAX31865 sensor support, fix MAX31855 sensor.
# MAX31865
Added support for the MAX31865 RTD-to-Digital Converter to measure PT100 and
similar RTDs. Verified with an Adafruit unit (product ID: 3328) and a PT100
probe.
# MAX31855
This was setup for incorrect SPI clock polarity and phase, and would return bad
data due to a race condition measuring on the wrong edge (verified with Saleae
Logic scope). Selecting the correct configuration fixes that problem.
Re-wrote the decode off the datasheet to handle error states better (sends NaN
as an update on failure to read temperature, which shows the value as Unknown
in Home Assistant).
Added the *optional* ability to monitor the internal high-precision temperature
sensor, which can be nice in some applications.
* Tests for MAX31855/MAX38165.
* Update style to match project rules.
Also fix CONF_REFERENCE_RESISTANCE and CONF_REFERENCE_TEMPERATURE being defined
multiple places. Missed this when I added them to const.py.
* Update style to match project rules.
Pylint line limit 101/100 ("missed it by that much").
Also apparently I can't read and patched the wrong line in max31855.cpp.
* Minor string/style cleanup.
There was a copy-paste leftover in max31855.cpp and max31865/sensor.py had
unnecessary whitespace.
* Improve MAX31865 fault detection and logging.
Log levels are more in-line with the documented descriptions.
Fault detection code is improved. A transient fault between reads is still
reported, but now only faults *during* a read cause the sensor to fail and
return NAN ("unknown" in Home Assistant).
* Update style to match project rules.
I just now realized the .clang-format and pylintrc files are included. D'oh!
* MAX31855 & MAX31865 code style alignment.
@OttoWinter caught some style mismatches, updated to match project better.
* Fix a lost '\' in max31865/sensor.py.
* new Fujitsu-General climate component
* Refactor out climate_ir
CC @glmnet
Refactored out climate_ir python files too.
Fixed invalid namespace name for climate_ir.
* Add namespace lint check
* Refactor Fujitsu Climate to climate_ir
Co-authored-by: Otto Winter <otto@otto-winter.com>
* web_server_base AUTO_LOAD includes ASYNC_TCP
fix AUTO_LOAD of web_server_base to include ASYNC_TCP
* Remove from dependencies
Co-authored-by: Otto Winter <otto@otto-winter.com>
* Add support for Sensirion STS3x Temperature sensors
* Removed humidty reading from STS3x sensor
* Fixed line error and operand error
* Fixed syntax
* Add test snippet for STS3x sensor
* Clean up
* #550 Proactive fix for STS3x component reporting WARNING status and reinitialzing similar to SHT3xd
* Flattened config.
* Fixed missing temperature unit
* Code formatting
* Added marking for future commands
* Cleanup
* Removed whitespace
* Cleanup
* Cleanup
* Add support for Sensirion STS3x Temperature sensors
* Removed humidty reading from STS3x sensor
* Fixed line error and operand error
* Fixed syntax
* Add test snippet for STS3x sensor
* Clean up
* Add support for Sensirion SHTC1 and SHTC3 Temperature sensors
* Fixed the test
* Fix lint issues
* Update esphome/components/shtcx/shtcx.cpp
Good point.
Co-Authored-By: Otto Winter <otto@otto-winter.com>
* Refactored device type identification and logging
* Refactoring and cleanup
* Remove sts3x
Co-authored-by: Otto Winter <otto@otto-winter.com>
* Add support for SGP30 eCO2 and TVOC sensors
* Added test for SGP30
* Lint issues fixed
* Lint fixes
* Fixed light lengths
* Cleanup
* Add support for Sensirion SCD30 CO2 sensors
* Fixed few lint issues
* Lint fixes
* Fixed line ending for lint
* Cleanup
* Refactored float conversion
* Refactor unnecessary return
* Refactoring and cleanup
* Updated uptime_sensor_ referencing and simplified checking on availability of copensation
* Temperature and Humidity source moved to a separate compensation block; Dependency for Uptime sensor removed.
* Both humidity_source and temperature_source are now mandatory if the compensation block is defined;
* Clean up
* Cleanup
* Cleanup in search of perfection
* Use correct comment style
Co-authored-by: Otto Winter <otto@otto-winter.com>
* add ssd1325 component
* fix i2c
* remove ssd1325 i2c
* add test
* set max contrast
* No macros - see styleguide
* Remove invalid function
* Formatting
Co-authored-by: Otto Winter <otto@otto-winter.com>