api: wifi: ap: ssid: "Thermostat" password: "MySecretThemostat" opentherm: in_pin: 4 out_pin: 5 ch_enable: true dhw_enable: false cooling_enable: false otc_active: false ch2_active: true t_room: boiler_sensor summer_mode_active: true dhw_block: true sync_mode: true output: - platform: opentherm t_set: id: t_set min_value: 20 auto_max_value: true zero_means_zero: true t_set_ch2: id: t_set_ch2 min_value: 20 max_value: 40 zero_means_zero: true number: - platform: opentherm cooling_control: name: "Boiler Cooling control signal" t_dhw_set: name: "Boiler DHW Setpoint" max_t_set: name: "Boiler Max Setpoint" t_room_set: name: "Boiler Room Setpoint" t_room_set_ch2: name: "Boiler Room Setpoint CH2" max_rel_mod_level: name: "Maximum relative modulation level" otc_hc_ratio: name: "OTC heat curve ratio" sensor: - platform: opentherm rel_mod_level: name: "Boiler Relative modulation level" ch_pressure: name: "Boiler Water pressure in CH circuit" dhw_flow_rate: name: "Boiler Water flow rate in DHW circuit" t_boiler: id: "boiler_sensor" name: "Boiler water temperature" t_dhw: name: "Boiler DHW temperature" t_outside: name: "Boiler Outside temperature" t_ret: name: "Boiler Return water temperature" t_storage: name: "Boiler Solar storage temperature" t_collector: name: "Boiler Solar collector temperature" t_flow_ch2: name: "Boiler Flow water temperature CH2 circuit" t_dhw2: name: "Boiler Domestic hot water temperature 2" t_exhaust: name: "Boiler Exhaust temperature" burner_starts: name: "Boiler Number of starts burner" ch_pump_starts: name: "Boiler Number of starts CH pump" dhw_pump_valve_starts: name: "Boiler Number of starts DHW pump/valve" dhw_burner_starts: name: "Boiler Number of starts burner during DHW mode" burner_operation_hours: name: "Boiler Number of hours that burner is in operation (i.e. flame on)" ch_pump_operation_hours: name: "Boiler Number of hours that CH pump has been running" dhw_pump_valve_operation_hours: name: "Boiler Number of hours that DHW pump has been running or DHW valve has been opened" dhw_burner_operation_hours: name: "Boiler Number of hours that burner is in operation during DHW mode" t_dhw_set_ub: name: "Boiler Upper bound for adjustement of DHW setpoint" t_dhw_set_lb: name: "Boiler Lower bound for adjustement of DHW setpoint" max_t_set_ub: name: "Boiler Upper bound for adjustement of max CH setpoint" max_t_set_lb: name: "Boiler Lower bound for adjustement of max CH setpoint" t_dhw_set: name: "Boiler Domestic hot water temperature setpoint" max_t_set: name: "Boiler Maximum allowable CH water setpoint" otc_hc_ratio_ub: name: "OTC heat curve ratio upper bound" otc_hc_ratio_lb: name: "OTC heat curve ratio lower bound" binary_sensor: - platform: opentherm fault_indication: name: "Boiler Fault indication" ch_active: name: "Boiler Central Heating active" dhw_active: name: "Boiler Domestic Hot Water active" flame_on: name: "Boiler Flame on" cooling_active: name: "Boiler Cooling active" ch2_active: name: "Boiler Central Heating 2 active" diagnostic_indication: name: "Boiler Diagnostic event" dhw_present: name: "Boiler DHW present" control_type_on_off: name: "Boiler Control type is on/off" cooling_supported: name: "Boiler Cooling supported" dhw_storage_tank: name: "Boiler DHW storage tank" controller_pump_control_allowed: name: "Boiler Controller pump control allowed" ch2_present: name: "Boiler CH2 present" dhw_setpoint_transfer_enabled: name: "Boiler DHW setpoint transfer enabled" max_ch_setpoint_transfer_enabled: name: "Boiler CH maximum setpoint transfer enabled" dhw_setpoint_rw: name: "Boiler DHW setpoint read/write" max_ch_setpoint_rw: name: "Boiler CH maximum setpoint read/write" switch: - platform: opentherm ch_enable: name: "Boiler Central Heating enabled" restore_mode: RESTORE_DEFAULT_ON dhw_enable: name: "Boiler Domestic Hot Water enabled" cooling_enable: name: "Boiler Cooling enabled" restore_mode: ALWAYS_OFF otc_active: name: "Boiler Outside temperature compensation active" ch2_active: name: "Boiler Central Heating 2 active"