import esphome.codegen as cg import esphome.config_validation as cv from esphome.components import i2c, sensor from esphome.const import ( CONF_HUMIDITY, CONF_ID, CONF_IIR_FILTER, CONF_OVERSAMPLING, CONF_PRESSURE, CONF_TEMPERATURE, DEVICE_CLASS_HUMIDITY, DEVICE_CLASS_PRESSURE, DEVICE_CLASS_TEMPERATURE, STATE_CLASS_MEASUREMENT, UNIT_CELSIUS, UNIT_HECTOPASCAL, UNIT_PERCENT, ) DEPENDENCIES = ["i2c"] bme280_ns = cg.esphome_ns.namespace("bme280") BME280Oversampling = bme280_ns.enum("BME280Oversampling") OVERSAMPLING_OPTIONS = { "NONE": BME280Oversampling.BME280_OVERSAMPLING_NONE, "1X": BME280Oversampling.BME280_OVERSAMPLING_1X, "2X": BME280Oversampling.BME280_OVERSAMPLING_2X, "4X": BME280Oversampling.BME280_OVERSAMPLING_4X, "8X": BME280Oversampling.BME280_OVERSAMPLING_8X, "16X": BME280Oversampling.BME280_OVERSAMPLING_16X, } BME280IIRFilter = bme280_ns.enum("BME280IIRFilter") IIR_FILTER_OPTIONS = { "OFF": BME280IIRFilter.BME280_IIR_FILTER_OFF, "2X": BME280IIRFilter.BME280_IIR_FILTER_2X, "4X": BME280IIRFilter.BME280_IIR_FILTER_4X, "8X": BME280IIRFilter.BME280_IIR_FILTER_8X, "16X": BME280IIRFilter.BME280_IIR_FILTER_16X, } BME280Component = bme280_ns.class_( "BME280Component", cg.PollingComponent, i2c.I2CDevice ) CONFIG_SCHEMA = ( cv.Schema( { cv.GenerateID(): cv.declare_id(BME280Component), cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema( unit_of_measurement=UNIT_CELSIUS, accuracy_decimals=1, device_class=DEVICE_CLASS_TEMPERATURE, state_class=STATE_CLASS_MEASUREMENT, ).extend( { cv.Optional(CONF_OVERSAMPLING, default="16X"): cv.enum( OVERSAMPLING_OPTIONS, upper=True ), } ), cv.Optional(CONF_PRESSURE): sensor.sensor_schema( unit_of_measurement=UNIT_HECTOPASCAL, accuracy_decimals=1, device_class=DEVICE_CLASS_PRESSURE, state_class=STATE_CLASS_MEASUREMENT, ).extend( { cv.Optional(CONF_OVERSAMPLING, default="16X"): cv.enum( OVERSAMPLING_OPTIONS, upper=True ), } ), cv.Optional(CONF_HUMIDITY): sensor.sensor_schema( unit_of_measurement=UNIT_PERCENT, accuracy_decimals=1, device_class=DEVICE_CLASS_HUMIDITY, state_class=STATE_CLASS_MEASUREMENT, ).extend( { cv.Optional(CONF_OVERSAMPLING, default="16X"): cv.enum( OVERSAMPLING_OPTIONS, upper=True ), } ), cv.Optional(CONF_IIR_FILTER, default="OFF"): cv.enum( IIR_FILTER_OPTIONS, upper=True ), } ) .extend(cv.polling_component_schema("60s")) .extend(i2c.i2c_device_schema(0x77)) ) async def to_code(config): var = cg.new_Pvariable(config[CONF_ID]) await cg.register_component(var, config) await i2c.register_i2c_device(var, config) if CONF_TEMPERATURE in config: conf = config[CONF_TEMPERATURE] sens = await sensor.new_sensor(conf) cg.add(var.set_temperature_sensor(sens)) cg.add(var.set_temperature_oversampling(conf[CONF_OVERSAMPLING])) if CONF_PRESSURE in config: conf = config[CONF_PRESSURE] sens = await sensor.new_sensor(conf) cg.add(var.set_pressure_sensor(sens)) cg.add(var.set_pressure_oversampling(conf[CONF_OVERSAMPLING])) if CONF_HUMIDITY in config: conf = config[CONF_HUMIDITY] sens = await sensor.new_sensor(conf) cg.add(var.set_humidity_sensor(sens)) cg.add(var.set_humidity_oversampling(conf[CONF_OVERSAMPLING])) cg.add(var.set_iir_filter(config[CONF_IIR_FILTER]))