import esphome.codegen as cg import esphome.config_validation as cv from esphome.components import sensor from esphome.const import ( CONF_GAS_RESISTANCE, CONF_HUMIDITY, CONF_PRESSURE, CONF_TEMPERATURE, DEVICE_CLASS_HUMIDITY, DEVICE_CLASS_PRESSURE, DEVICE_CLASS_TEMPERATURE, STATE_CLASS_MEASUREMENT, UNIT_CELSIUS, UNIT_HECTOPASCAL, UNIT_OHM, UNIT_PARTS_PER_MILLION, UNIT_PERCENT, ICON_GAS_CYLINDER, ICON_GAUGE, ICON_THERMOMETER, ICON_WATER_PERCENT, ) from . import ( BME680BSECComponent, CONF_BME680_BSEC_ID, CONF_SAMPLE_RATE, SAMPLE_RATE_OPTIONS, ) DEPENDENCIES = ["bme680_bsec"] CONF_IAQ = "iaq" CONF_IAQ_ACCURACY = "iaq_accuracy" CONF_CO2_EQUIVALENT = "co2_equivalent" CONF_BREATH_VOC_EQUIVALENT = "breath_voc_equivalent" UNIT_IAQ = "IAQ" ICON_ACCURACY = "mdi:checkbox-marked-circle-outline" ICON_TEST_TUBE = "mdi:test-tube" TYPES = [ CONF_TEMPERATURE, CONF_PRESSURE, CONF_HUMIDITY, CONF_GAS_RESISTANCE, CONF_IAQ, CONF_IAQ_ACCURACY, CONF_CO2_EQUIVALENT, CONF_BREATH_VOC_EQUIVALENT, ] CONFIG_SCHEMA = cv.Schema( { cv.GenerateID(CONF_BME680_BSEC_ID): cv.use_id(BME680BSECComponent), cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema( unit_of_measurement=UNIT_CELSIUS, icon=ICON_THERMOMETER, accuracy_decimals=1, device_class=DEVICE_CLASS_TEMPERATURE, state_class=STATE_CLASS_MEASUREMENT, ).extend( {cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)} ), cv.Optional(CONF_PRESSURE): sensor.sensor_schema( unit_of_measurement=UNIT_HECTOPASCAL, icon=ICON_GAUGE, accuracy_decimals=1, device_class=DEVICE_CLASS_PRESSURE, state_class=STATE_CLASS_MEASUREMENT, ).extend( {cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)} ), cv.Optional(CONF_HUMIDITY): sensor.sensor_schema( unit_of_measurement=UNIT_PERCENT, icon=ICON_WATER_PERCENT, accuracy_decimals=1, device_class=DEVICE_CLASS_HUMIDITY, state_class=STATE_CLASS_MEASUREMENT, ).extend( {cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)} ), cv.Optional(CONF_GAS_RESISTANCE): sensor.sensor_schema( unit_of_measurement=UNIT_OHM, icon=ICON_GAS_CYLINDER, accuracy_decimals=0, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_IAQ): sensor.sensor_schema( unit_of_measurement=UNIT_IAQ, icon=ICON_GAUGE, accuracy_decimals=0, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_IAQ_ACCURACY): sensor.sensor_schema( icon=ICON_ACCURACY, accuracy_decimals=0, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_CO2_EQUIVALENT): sensor.sensor_schema( unit_of_measurement=UNIT_PARTS_PER_MILLION, icon=ICON_TEST_TUBE, accuracy_decimals=1, state_class=STATE_CLASS_MEASUREMENT, ), cv.Optional(CONF_BREATH_VOC_EQUIVALENT): sensor.sensor_schema( unit_of_measurement=UNIT_PARTS_PER_MILLION, icon=ICON_TEST_TUBE, accuracy_decimals=1, state_class=STATE_CLASS_MEASUREMENT, ), } ) async def setup_conf(config, key, hub): if key in config: conf = config[key] sens = await sensor.new_sensor(conf) cg.add(getattr(hub, f"set_{key}_sensor")(sens)) if CONF_SAMPLE_RATE in conf: cg.add(getattr(hub, f"set_{key}_sample_rate")(conf[CONF_SAMPLE_RATE])) async def to_code(config): hub = await cg.get_variable(config[CONF_BME680_BSEC_ID]) for key in TYPES: await setup_conf(config, key, hub)