esphome/tests/components/opentherm/common.yaml
Oleg Tarasov 21cb941bbe
Some checks failed
CI / Create common environment (push) Has been cancelled
YAML lint / yamllint (push) Has been cancelled
CI / Check black (push) Has been cancelled
CI / Check flake8 (push) Has been cancelled
CI / Check pylint (push) Has been cancelled
CI / Check pyupgrade (push) Has been cancelled
CI / Run script/ci-custom (push) Has been cancelled
CI / Run pytest (push) Has been cancelled
CI / Check clang-format (push) Has been cancelled
CI / Run script/clang-tidy for ESP32 Arduino 1/4 (push) Has been cancelled
CI / Run script/clang-tidy for ESP32 Arduino 2/4 (push) Has been cancelled
CI / Run script/clang-tidy for ESP32 Arduino 3/4 (push) Has been cancelled
CI / Run script/clang-tidy for ESP32 Arduino 4/4 (push) Has been cancelled
CI / Run script/clang-tidy for ESP32 IDF (push) Has been cancelled
CI / Run script/clang-tidy for ESP8266 (push) Has been cancelled
CI / list-components (push) Has been cancelled
CI / Component test (push) Has been cancelled
CI / Split components for testing into 20 groups maximum (push) Has been cancelled
CI / Test split components (push) Has been cancelled
CI / CI Status (push) Has been cancelled
Add OpenTherm component (part 2.1: sensor platform) (#7529)
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
2024-10-25 15:00:28 +13:00

76 lines
2.4 KiB
YAML

api:
wifi:
ap:
ssid: "Thermostat"
password: "MySecretThemostat"
opentherm:
in_pin: 4
out_pin: 5
ch_enable: true
dhw_enable: false
cooling_enable: false
otc_active: false
ch2_active: true
summer_mode_active: true
dhw_block: true
sync_mode: true
sensor:
- platform: opentherm
rel_mod_level:
name: "Boiler Relative modulation level"
ch_pressure:
name: "Boiler Water pressure in CH circuit"
dhw_flow_rate:
name: "Boiler Water flow rate in DHW circuit"
t_boiler:
name: "Boiler water temperature"
t_dhw:
name: "Boiler DHW temperature"
t_outside:
name: "Boiler Outside temperature"
t_ret:
name: "Boiler Return water temperature"
t_storage:
name: "Boiler Solar storage temperature"
t_collector:
name: "Boiler Solar collector temperature"
t_flow_ch2:
name: "Boiler Flow water temperature CH2 circuit"
t_dhw2:
name: "Boiler Domestic hot water temperature 2"
t_exhaust:
name: "Boiler Exhaust temperature"
burner_starts:
name: "Boiler Number of starts burner"
ch_pump_starts:
name: "Boiler Number of starts CH pump"
dhw_pump_valve_starts:
name: "Boiler Number of starts DHW pump/valve"
dhw_burner_starts:
name: "Boiler Number of starts burner during DHW mode"
burner_operation_hours:
name: "Boiler Number of hours that burner is in operation (i.e. flame on)"
ch_pump_operation_hours:
name: "Boiler Number of hours that CH pump has been running"
dhw_pump_valve_operation_hours:
name: "Boiler Number of hours that DHW pump has been running or DHW valve has been opened"
dhw_burner_operation_hours:
name: "Boiler Number of hours that burner is in operation during DHW mode"
t_dhw_set_ub:
name: "Boiler Upper bound for adjustement of DHW setpoint"
t_dhw_set_lb:
name: "Boiler Lower bound for adjustement of DHW setpoint"
max_t_set_ub:
name: "Boiler Upper bound for adjustement of max CH setpoint"
max_t_set_lb:
name: "Boiler Lower bound for adjustement of max CH setpoint"
t_dhw_set:
name: "Boiler Domestic hot water temperature setpoint"
max_t_set:
name: "Boiler Maximum allowable CH water setpoint"
otc_hc_ratio_ub:
name: "OTC heat curve ratio upper bound"
otc_hc_ratio_lb:
name: "OTC heat curve ratio lower bound"