import esphome.codegen as cg
|
|
import esphome.config_validation as cv
|
|
from esphome.components import i2c, sensor
|
|
from esphome.const import (
|
|
CONF_ID,
|
|
CONF_TEMPERATURE,
|
|
CONF_HUMIDITY,
|
|
STATE_CLASS_MEASUREMENT,
|
|
UNIT_CELSIUS,
|
|
UNIT_PERCENT,
|
|
ICON_THERMOMETER,
|
|
ICON_WATER_PERCENT,
|
|
DEVICE_CLASS_TEMPERATURE,
|
|
DEVICE_CLASS_HUMIDITY,
|
|
)
|
|
|
|
CODEOWNERS = ["@sjtrny"]
|
|
DEPENDENCIES = ["i2c"]
|
|
|
|
sht4x_ns = cg.esphome_ns.namespace("sht4x")
|
|
|
|
SHT4XComponent = sht4x_ns.class_("SHT4XComponent", cg.PollingComponent, i2c.I2CDevice)
|
|
|
|
CONF_PRECISION = "precision"
|
|
SHT4XPRECISION = sht4x_ns.enum("SHT4XPRECISION")
|
|
PRECISION_OPTIONS = {
|
|
"High": SHT4XPRECISION.SHT4X_PRECISION_HIGH,
|
|
"Med": SHT4XPRECISION.SHT4X_PRECISION_MED,
|
|
"Low": SHT4XPRECISION.SHT4X_PRECISION_LOW,
|
|
}
|
|
|
|
CONF_HEATER_POWER = "heater_power"
|
|
SHT4XHEATERPOWER = sht4x_ns.enum("SHT4XHEATERPOWER")
|
|
HEATER_POWER_OPTIONS = {
|
|
"High": SHT4XHEATERPOWER.SHT4X_HEATERPOWER_HIGH,
|
|
"Med": SHT4XHEATERPOWER.SHT4X_HEATERPOWER_MED,
|
|
"Low": SHT4XHEATERPOWER.SHT4X_HEATERPOWER_LOW,
|
|
}
|
|
|
|
CONF_HEATER_TIME = "heater_time"
|
|
SHT4XHEATERTIME = sht4x_ns.enum("SHT4XHEATERTIME")
|
|
HEATER_TIME_OPTIONS = {
|
|
"Long": SHT4XHEATERTIME.SHT4X_HEATERTIME_LONG,
|
|
"Short": SHT4XHEATERTIME.SHT4X_HEATERTIME_SHORT,
|
|
}
|
|
|
|
CONF_HEATER_MAX_DUTY = "heater_max_duty"
|
|
|
|
CONFIG_SCHEMA = (
|
|
cv.Schema(
|
|
{
|
|
cv.GenerateID(): cv.declare_id(SHT4XComponent),
|
|
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
icon=ICON_THERMOMETER,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_PERCENT,
|
|
icon=ICON_WATER_PERCENT,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_HUMIDITY,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_PRECISION, default="High"): cv.enum(PRECISION_OPTIONS),
|
|
cv.Optional(CONF_HEATER_POWER, default="High"): cv.enum(
|
|
HEATER_POWER_OPTIONS
|
|
),
|
|
cv.Optional(CONF_HEATER_TIME, default="Long"): cv.enum(HEATER_TIME_OPTIONS),
|
|
cv.Optional(CONF_HEATER_MAX_DUTY, default=0.0): cv.float_range(
|
|
min=0.0, max=0.05
|
|
),
|
|
}
|
|
)
|
|
.extend(cv.polling_component_schema("60s"))
|
|
.extend(i2c.i2c_device_schema(0x44))
|
|
)
|
|
|
|
TYPES = {
|
|
CONF_TEMPERATURE: "set_temp_sensor",
|
|
CONF_HUMIDITY: "set_humidity_sensor",
|
|
}
|
|
|
|
|
|
async def to_code(config):
|
|
var = cg.new_Pvariable(config[CONF_ID])
|
|
await cg.register_component(var, config)
|
|
await i2c.register_i2c_device(var, config)
|
|
|
|
cg.add(var.set_precision_value(config[CONF_PRECISION]))
|
|
cg.add(var.set_heater_power_value(config[CONF_HEATER_POWER]))
|
|
cg.add(var.set_heater_time_value(config[CONF_HEATER_TIME]))
|
|
cg.add(var.set_heater_duty_value(config[CONF_HEATER_MAX_DUTY]))
|
|
|
|
for key, funcName in TYPES.items():
|
|
|
|
if key in config:
|
|
sens = await sensor.new_sensor(config[key])
|
|
cg.add(getattr(var, funcName)(sens))
|