esphome/esphome/components/selec_meter/sensor.py

165 lines
5.4 KiB
Python

import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import sensor, modbus
from esphome.const import (
CONF_ACTIVE_POWER,
CONF_APPARENT_POWER,
CONF_CURRENT,
CONF_EXPORT_ACTIVE_ENERGY,
CONF_EXPORT_REACTIVE_ENERGY,
CONF_FREQUENCY,
CONF_ID,
CONF_IMPORT_ACTIVE_ENERGY,
CONF_IMPORT_REACTIVE_ENERGY,
CONF_POWER_FACTOR,
CONF_REACTIVE_POWER,
CONF_VOLTAGE,
DEVICE_CLASS_CURRENT,
DEVICE_CLASS_ENERGY,
DEVICE_CLASS_POWER,
DEVICE_CLASS_POWER_FACTOR,
DEVICE_CLASS_VOLTAGE,
ICON_CURRENT_AC,
STATE_CLASS_MEASUREMENT,
STATE_CLASS_TOTAL_INCREASING,
UNIT_AMPERE,
UNIT_HERTZ,
UNIT_VOLT,
UNIT_VOLT_AMPS,
UNIT_VOLT_AMPS_REACTIVE,
UNIT_WATT,
)
AUTO_LOAD = ["modbus"]
CODEOWNERS = ["@sourabhjaiswal"]
CONF_TOTAL_ACTIVE_ENERGY = "total_active_energy"
CONF_TOTAL_REACTIVE_ENERGY = "total_reactive_energy"
CONF_APPARENT_ENERGY = "apparent_energy"
CONF_MAXIMUM_DEMAND_ACTIVE_POWER = "maximum_demand_active_power"
CONF_MAXIMUM_DEMAND_REACTIVE_POWER = "maximum_demand_reactive_power"
CONF_MAXIMUM_DEMAND_APPARENT_POWER = "maximum_demand_apparent_power"
UNIT_KILOWATT_HOURS = "kWh"
UNIT_KILOVOLT_AMPS_HOURS = "kVAh"
UNIT_KILOVOLT_AMPS_REACTIVE_HOURS = "kVARh"
selec_meter_ns = cg.esphome_ns.namespace("selec_meter")
SelecMeter = selec_meter_ns.class_(
"SelecMeter", cg.PollingComponent, modbus.ModbusDevice
)
SENSORS = {
CONF_TOTAL_ACTIVE_ENERGY: sensor.sensor_schema(
unit_of_measurement=UNIT_KILOWATT_HOURS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_ENERGY,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
CONF_IMPORT_ACTIVE_ENERGY: sensor.sensor_schema(
unit_of_measurement=UNIT_KILOWATT_HOURS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_ENERGY,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
CONF_EXPORT_ACTIVE_ENERGY: sensor.sensor_schema(
unit_of_measurement=UNIT_KILOWATT_HOURS,
accuracy_decimals=2,
device_class=DEVICE_CLASS_ENERGY,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
CONF_TOTAL_REACTIVE_ENERGY: sensor.sensor_schema(
unit_of_measurement=UNIT_KILOVOLT_AMPS_REACTIVE_HOURS,
accuracy_decimals=2,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
CONF_IMPORT_REACTIVE_ENERGY: sensor.sensor_schema(
unit_of_measurement=UNIT_KILOVOLT_AMPS_REACTIVE_HOURS,
accuracy_decimals=2,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
CONF_EXPORT_REACTIVE_ENERGY: sensor.sensor_schema(
unit_of_measurement=UNIT_KILOVOLT_AMPS_REACTIVE_HOURS,
accuracy_decimals=2,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
CONF_APPARENT_ENERGY: sensor.sensor_schema(
unit_of_measurement=UNIT_KILOVOLT_AMPS_HOURS,
accuracy_decimals=2,
state_class=STATE_CLASS_TOTAL_INCREASING,
),
CONF_ACTIVE_POWER: sensor.sensor_schema(
unit_of_measurement=UNIT_WATT,
accuracy_decimals=3,
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_REACTIVE_POWER: sensor.sensor_schema(
unit_of_measurement=UNIT_VOLT_AMPS_REACTIVE,
accuracy_decimals=3,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_APPARENT_POWER: sensor.sensor_schema(
unit_of_measurement=UNIT_VOLT_AMPS,
accuracy_decimals=3,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_VOLTAGE: sensor.sensor_schema(
unit_of_measurement=UNIT_VOLT,
accuracy_decimals=2,
device_class=DEVICE_CLASS_VOLTAGE,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_CURRENT: sensor.sensor_schema(
unit_of_measurement=UNIT_AMPERE,
accuracy_decimals=3,
device_class=DEVICE_CLASS_CURRENT,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_POWER_FACTOR: sensor.sensor_schema(
accuracy_decimals=3,
device_class=DEVICE_CLASS_POWER_FACTOR,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_FREQUENCY: sensor.sensor_schema(
unit_of_measurement=UNIT_HERTZ,
icon=ICON_CURRENT_AC,
accuracy_decimals=2,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_MAXIMUM_DEMAND_ACTIVE_POWER: sensor.sensor_schema(
unit_of_measurement=UNIT_WATT,
accuracy_decimals=3,
device_class=DEVICE_CLASS_POWER,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_MAXIMUM_DEMAND_REACTIVE_POWER: sensor.sensor_schema(
unit_of_measurement=UNIT_VOLT_AMPS_REACTIVE,
accuracy_decimals=3,
state_class=STATE_CLASS_MEASUREMENT,
),
CONF_MAXIMUM_DEMAND_APPARENT_POWER: sensor.sensor_schema(
unit_of_measurement=UNIT_VOLT_AMPS,
accuracy_decimals=3,
state_class=STATE_CLASS_MEASUREMENT,
),
}
CONFIG_SCHEMA = (
cv.Schema({cv.GenerateID(): cv.declare_id(SelecMeter)})
.extend(
{cv.Optional(sensor_name): schema for sensor_name, schema in SENSORS.items()}
)
.extend(cv.polling_component_schema("10s"))
.extend(modbus.modbus_device_schema(0x01))
)
async def to_code(config):
var = cg.new_Pvariable(config[CONF_ID])
await cg.register_component(var, config)
await modbus.register_modbus_device(var, config)
for name in SENSORS:
if name in config:
sens = await sensor.new_sensor(config[name])
cg.add(getattr(var, f"set_{name}_sensor")(sens))