mirror of
https://github.com/esphome/esphome.git
synced 2024-11-22 15:08:10 +01:00
My Home-IoT
36ffef083b
In a heavy EMI environment, reading the current config from the MAX31865 can fail, such as switching from a 4-wire sensor to a 3-wire sensor. This causes the temperature value to be off wildly, but still technically valid, so it doesn't get reported as a sensor failure. Since we know what configuration we want, rather than send it to the MAX31865 on setup and ask for it over and over (propagating any error as we write it back), instead store the base configuration and work from that to change modes. This not only avoids propagating any error, it also saves a lot of unnecessary reads from the MAX31865. |
||
---|---|---|
.github | ||
docker | ||
esphome | ||
script | ||
tests | ||
.clang-format | ||
.clang-tidy | ||
.dockerignore | ||
.editorconfig | ||
.gitignore | ||
.gitlab-ci.yml | ||
.gitpod.yml | ||
.travis.yml | ||
CODE_OF_CONDUCT.md | ||
CONTRIBUTING.md | ||
LICENSE | ||
MANIFEST.in | ||
platformio.ini | ||
pylintrc | ||
README.md | ||
requirements.txt | ||
requirements_test.txt | ||
setup.cfg | ||
setup.py |
ESPHome
Documentation: https://esphome.io/
For issues, please go to the issue tracker.
For feature requests, please see feature requests.