#include "selec_meter.h"
|
|
#include "selec_meter_registers.h"
|
|
#include "esphome/core/log.h"
|
|
|
|
namespace esphome {
|
|
namespace selec_meter {
|
|
|
|
static const char *const TAG = "selec_meter";
|
|
|
|
static const uint8_t MODBUS_CMD_READ_IN_REGISTERS = 0x04;
|
|
static const uint8_t MODBUS_REGISTER_COUNT = 34; // 34 x 16-bit registers
|
|
|
|
void SelecMeter::on_modbus_data(const std::vector<uint8_t> &data) {
|
|
if (data.size() < MODBUS_REGISTER_COUNT * 2) {
|
|
ESP_LOGW(TAG, "Invalid size for SelecMeter!");
|
|
return;
|
|
}
|
|
|
|
auto selec_meter_get_float = [&](size_t i, float unit) -> float {
|
|
uint32_t temp = encode_uint32(data[i + 2], data[i + 3], data[i], data[i + 1]);
|
|
|
|
float f;
|
|
memcpy(&f, &temp, sizeof(f));
|
|
return (f * unit);
|
|
};
|
|
|
|
float total_active_energy = selec_meter_get_float(SELEC_TOTAL_ACTIVE_ENERGY * 2, NO_DEC_UNIT);
|
|
float import_active_energy = selec_meter_get_float(SELEC_IMPORT_ACTIVE_ENERGY * 2, NO_DEC_UNIT);
|
|
float export_active_energy = selec_meter_get_float(SELEC_EXPORT_ACTIVE_ENERGY * 2, NO_DEC_UNIT);
|
|
float total_reactive_energy = selec_meter_get_float(SELEC_TOTAL_REACTIVE_ENERGY * 2, NO_DEC_UNIT);
|
|
float import_reactive_energy = selec_meter_get_float(SELEC_IMPORT_REACTIVE_ENERGY * 2, NO_DEC_UNIT);
|
|
float export_reactive_energy = selec_meter_get_float(SELEC_EXPORT_REACTIVE_ENERGY * 2, NO_DEC_UNIT);
|
|
float apparent_energy = selec_meter_get_float(SELEC_APPARENT_ENERGY * 2, NO_DEC_UNIT);
|
|
float active_power = selec_meter_get_float(SELEC_ACTIVE_POWER * 2, MULTIPLY_THOUSAND_UNIT);
|
|
float reactive_power = selec_meter_get_float(SELEC_REACTIVE_POWER * 2, MULTIPLY_THOUSAND_UNIT);
|
|
float apparent_power = selec_meter_get_float(SELEC_APPARENT_POWER * 2, MULTIPLY_THOUSAND_UNIT);
|
|
float voltage = selec_meter_get_float(SELEC_VOLTAGE * 2, NO_DEC_UNIT);
|
|
float current = selec_meter_get_float(SELEC_CURRENT * 2, NO_DEC_UNIT);
|
|
float power_factor = selec_meter_get_float(SELEC_POWER_FACTOR * 2, NO_DEC_UNIT);
|
|
float frequency = selec_meter_get_float(SELEC_FREQUENCY * 2, NO_DEC_UNIT);
|
|
float maximum_demand_active_power =
|
|
selec_meter_get_float(SELEC_MAXIMUM_DEMAND_ACTIVE_POWER * 2, MULTIPLY_THOUSAND_UNIT);
|
|
float maximum_demand_reactive_power =
|
|
selec_meter_get_float(SELEC_MAXIMUM_DEMAND_REACTIVE_POWER * 2, MULTIPLY_THOUSAND_UNIT);
|
|
float maximum_demand_apparent_power =
|
|
selec_meter_get_float(SELEC_MAXIMUM_DEMAND_APPARENT_POWER * 2, MULTIPLY_THOUSAND_UNIT);
|
|
|
|
if (this->total_active_energy_sensor_ != nullptr)
|
|
this->total_active_energy_sensor_->publish_state(total_active_energy);
|
|
if (this->import_active_energy_sensor_ != nullptr)
|
|
this->import_active_energy_sensor_->publish_state(import_active_energy);
|
|
if (this->export_active_energy_sensor_ != nullptr)
|
|
this->export_active_energy_sensor_->publish_state(export_active_energy);
|
|
if (this->total_reactive_energy_sensor_ != nullptr)
|
|
this->total_reactive_energy_sensor_->publish_state(total_reactive_energy);
|
|
if (this->import_reactive_energy_sensor_ != nullptr)
|
|
this->import_reactive_energy_sensor_->publish_state(import_reactive_energy);
|
|
if (this->export_reactive_energy_sensor_ != nullptr)
|
|
this->export_reactive_energy_sensor_->publish_state(export_reactive_energy);
|
|
if (this->apparent_energy_sensor_ != nullptr)
|
|
this->apparent_energy_sensor_->publish_state(apparent_energy);
|
|
if (this->active_power_sensor_ != nullptr)
|
|
this->active_power_sensor_->publish_state(active_power);
|
|
if (this->reactive_power_sensor_ != nullptr)
|
|
this->reactive_power_sensor_->publish_state(reactive_power);
|
|
if (this->apparent_power_sensor_ != nullptr)
|
|
this->apparent_power_sensor_->publish_state(apparent_power);
|
|
if (this->voltage_sensor_ != nullptr)
|
|
this->voltage_sensor_->publish_state(voltage);
|
|
if (this->current_sensor_ != nullptr)
|
|
this->current_sensor_->publish_state(current);
|
|
if (this->power_factor_sensor_ != nullptr)
|
|
this->power_factor_sensor_->publish_state(power_factor);
|
|
if (this->frequency_sensor_ != nullptr)
|
|
this->frequency_sensor_->publish_state(frequency);
|
|
if (this->maximum_demand_active_power_sensor_ != nullptr)
|
|
this->maximum_demand_active_power_sensor_->publish_state(maximum_demand_active_power);
|
|
if (this->maximum_demand_reactive_power_sensor_ != nullptr)
|
|
this->maximum_demand_reactive_power_sensor_->publish_state(maximum_demand_reactive_power);
|
|
if (this->maximum_demand_apparent_power_sensor_ != nullptr)
|
|
this->maximum_demand_apparent_power_sensor_->publish_state(maximum_demand_apparent_power);
|
|
}
|
|
|
|
void SelecMeter::update() { this->send(MODBUS_CMD_READ_IN_REGISTERS, 0, MODBUS_REGISTER_COUNT); }
|
|
void SelecMeter::dump_config() {
|
|
ESP_LOGCONFIG(TAG, "SELEC Meter:");
|
|
ESP_LOGCONFIG(TAG, " Address: 0x%02X", this->address_);
|
|
LOG_SENSOR(" ", "Total Active Energy", this->total_active_energy_sensor_);
|
|
LOG_SENSOR(" ", "Import Active Energy", this->import_active_energy_sensor_);
|
|
LOG_SENSOR(" ", "Export Active Energy", this->export_active_energy_sensor_);
|
|
LOG_SENSOR(" ", "Total Reactive Energy", this->total_reactive_energy_sensor_);
|
|
LOG_SENSOR(" ", "Import Reactive Energy", this->import_reactive_energy_sensor_);
|
|
LOG_SENSOR(" ", "Export Reactive Energy", this->export_reactive_energy_sensor_);
|
|
LOG_SENSOR(" ", "Apparent Energy", this->apparent_energy_sensor_);
|
|
LOG_SENSOR(" ", "Active Power", this->active_power_sensor_);
|
|
LOG_SENSOR(" ", "Reactive Power", this->reactive_power_sensor_);
|
|
LOG_SENSOR(" ", "Apparent Power", this->apparent_power_sensor_);
|
|
LOG_SENSOR(" ", "Voltage", this->voltage_sensor_);
|
|
LOG_SENSOR(" ", "Current", this->current_sensor_);
|
|
LOG_SENSOR(" ", "Power Factor", this->power_factor_sensor_);
|
|
LOG_SENSOR(" ", "Frequency", this->frequency_sensor_);
|
|
LOG_SENSOR(" ", "Maximum Demand Active Power", this->maximum_demand_active_power_sensor_);
|
|
LOG_SENSOR(" ", "Maximum Demand Reactive Power", this->maximum_demand_reactive_power_sensor_);
|
|
LOG_SENSOR(" ", "Maximum Demand Apparent Power", this->maximum_demand_apparent_power_sensor_);
|
|
}
|
|
|
|
} // namespace selec_meter
|
|
} // namespace esphome
|