esphome/esphome/components/ota/__init__.py
Oxan van Leeuwen ceebe14628
Add ability to await safe mode in codegen (#4529)
* Add ability to await OTA safe mode

* Make pylint happy
2023-03-07 21:29:45 +00:00

127 lines
4.6 KiB
Python

from esphome.cpp_generator import RawExpression
import esphome.codegen as cg
import esphome.config_validation as cv
from esphome import automation
from esphome.const import (
CONF_ID,
CONF_NUM_ATTEMPTS,
CONF_PASSWORD,
CONF_PORT,
CONF_REBOOT_TIMEOUT,
CONF_SAFE_MODE,
CONF_TRIGGER_ID,
CONF_OTA,
KEY_PAST_SAFE_MODE,
)
from esphome.core import CORE, coroutine_with_priority
CODEOWNERS = ["@esphome/core"]
DEPENDENCIES = ["network"]
AUTO_LOAD = ["socket", "md5"]
CONF_ON_STATE_CHANGE = "on_state_change"
CONF_ON_BEGIN = "on_begin"
CONF_ON_PROGRESS = "on_progress"
CONF_ON_END = "on_end"
CONF_ON_ERROR = "on_error"
ota_ns = cg.esphome_ns.namespace("ota")
OTAState = ota_ns.enum("OTAState")
OTAComponent = ota_ns.class_("OTAComponent", cg.Component)
OTAStateChangeTrigger = ota_ns.class_(
"OTAStateChangeTrigger", automation.Trigger.template()
)
OTAStartTrigger = ota_ns.class_("OTAStartTrigger", automation.Trigger.template())
OTAProgressTrigger = ota_ns.class_("OTAProgressTrigger", automation.Trigger.template())
OTAEndTrigger = ota_ns.class_("OTAEndTrigger", automation.Trigger.template())
OTAErrorTrigger = ota_ns.class_("OTAErrorTrigger", automation.Trigger.template())
CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(): cv.declare_id(OTAComponent),
cv.Optional(CONF_SAFE_MODE, default=True): cv.boolean,
cv.SplitDefault(CONF_PORT, esp8266=8266, esp32=3232, rp2040=2040): cv.port,
cv.Optional(CONF_PASSWORD): cv.string,
cv.Optional(
CONF_REBOOT_TIMEOUT, default="5min"
): cv.positive_time_period_milliseconds,
cv.Optional(CONF_NUM_ATTEMPTS, default="10"): cv.positive_not_null_int,
cv.Optional(CONF_ON_STATE_CHANGE): automation.validate_automation(
{
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(OTAStateChangeTrigger),
}
),
cv.Optional(CONF_ON_BEGIN): automation.validate_automation(
{
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(OTAStartTrigger),
}
),
cv.Optional(CONF_ON_ERROR): automation.validate_automation(
{
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(OTAErrorTrigger),
}
),
cv.Optional(CONF_ON_PROGRESS): automation.validate_automation(
{
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(OTAProgressTrigger),
}
),
cv.Optional(CONF_ON_END): automation.validate_automation(
{
cv.GenerateID(CONF_TRIGGER_ID): cv.declare_id(OTAEndTrigger),
}
),
}
).extend(cv.COMPONENT_SCHEMA)
@coroutine_with_priority(50.0)
async def to_code(config):
CORE.data[CONF_OTA] = {}
var = cg.new_Pvariable(config[CONF_ID])
cg.add(var.set_port(config[CONF_PORT]))
cg.add_define("USE_OTA")
if CONF_PASSWORD in config:
cg.add(var.set_auth_password(config[CONF_PASSWORD]))
cg.add_define("USE_OTA_PASSWORD")
await cg.register_component(var, config)
if config[CONF_SAFE_MODE]:
condition = var.should_enter_safe_mode(
config[CONF_NUM_ATTEMPTS], config[CONF_REBOOT_TIMEOUT]
)
cg.add(RawExpression(f"if ({condition}) return"))
CORE.data[CONF_OTA][KEY_PAST_SAFE_MODE] = True
if CORE.is_esp32 and CORE.using_arduino:
cg.add_library("Update", None)
if CORE.is_rp2040 and CORE.using_arduino:
cg.add_library("Updater", None)
use_state_callback = False
for conf in config.get(CONF_ON_STATE_CHANGE, []):
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
await automation.build_automation(trigger, [(OTAState, "state")], conf)
use_state_callback = True
for conf in config.get(CONF_ON_BEGIN, []):
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
await automation.build_automation(trigger, [], conf)
use_state_callback = True
for conf in config.get(CONF_ON_PROGRESS, []):
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
await automation.build_automation(trigger, [(float, "x")], conf)
use_state_callback = True
for conf in config.get(CONF_ON_END, []):
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
await automation.build_automation(trigger, [], conf)
use_state_callback = True
for conf in config.get(CONF_ON_ERROR, []):
trigger = cg.new_Pvariable(conf[CONF_TRIGGER_ID], var)
await automation.build_automation(trigger, [(int, "x")], conf)
use_state_callback = True
if use_state_callback:
cg.add_define("USE_OTA_STATE_CALLBACK")