esphome/esphome/components/ezo_pmp/sensor.py
Carlos Gustavo Sarmiento f30e54d177
Implementation for Atlas Scientific Peristaltic Pump (#3528)
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
2022-10-19 16:08:27 +13:00

104 lines
3.7 KiB
Python

import esphome.codegen as cg
import esphome.config_validation as cv
from esphome.components import sensor
from esphome.const import (
ENTITY_CATEGORY_DIAGNOSTIC,
ENTITY_CATEGORY_NONE,
DEVICE_CLASS_EMPTY,
DEVICE_CLASS_VOLTAGE,
STATE_CLASS_MEASUREMENT,
STATE_CLASS_NONE,
CONF_ID,
UNIT_VOLT,
)
from . import EzoPMP
DEPENDENCIES = ["ezo_pmp"]
CONF_CURRENT_VOLUME_DOSED = "current_volume_dosed"
CONF_TOTAL_VOLUME_DOSED = "total_volume_dosed"
CONF_ABSOLUTE_TOTAL_VOLUME_DOSED = "absolute_total_volume_dosed"
CONF_PUMP_VOLTAGE = "pump_voltage"
CONF_LAST_VOLUME_REQUESTED = "last_volume_requested"
CONF_MAX_FLOW_RATE = "max_flow_rate"
UNIT_MILILITER = "ml"
UNIT_MILILITERS_PER_MINUTE = "ml/min"
CONFIG_SCHEMA = cv.Schema(
{
cv.GenerateID(): cv.use_id(EzoPMP),
cv.Optional(CONF_CURRENT_VOLUME_DOSED): sensor.sensor_schema(
unit_of_measurement=UNIT_MILILITER,
accuracy_decimals=2,
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_MEASUREMENT,
entity_category=ENTITY_CATEGORY_NONE,
),
cv.Optional(CONF_LAST_VOLUME_REQUESTED): sensor.sensor_schema(
unit_of_measurement=UNIT_MILILITER,
accuracy_decimals=2,
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_MEASUREMENT,
entity_category=ENTITY_CATEGORY_NONE,
),
cv.Optional(CONF_MAX_FLOW_RATE): sensor.sensor_schema(
unit_of_measurement=UNIT_MILILITERS_PER_MINUTE,
accuracy_decimals=2,
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_NONE,
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
),
cv.Optional(CONF_TOTAL_VOLUME_DOSED): sensor.sensor_schema(
unit_of_measurement=UNIT_MILILITER,
accuracy_decimals=2,
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_MEASUREMENT,
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
),
cv.Optional(CONF_ABSOLUTE_TOTAL_VOLUME_DOSED): sensor.sensor_schema(
unit_of_measurement=UNIT_MILILITER,
accuracy_decimals=2,
device_class=DEVICE_CLASS_EMPTY,
state_class=STATE_CLASS_MEASUREMENT,
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
),
cv.Optional(CONF_PUMP_VOLTAGE): sensor.sensor_schema(
unit_of_measurement=UNIT_VOLT,
accuracy_decimals=2,
device_class=DEVICE_CLASS_VOLTAGE,
state_class=STATE_CLASS_MEASUREMENT,
entity_category=ENTITY_CATEGORY_DIAGNOSTIC,
),
}
)
async def to_code(config):
parent = await cg.get_variable(config[CONF_ID])
if CONF_CURRENT_VOLUME_DOSED in config:
sens = await sensor.new_sensor(config[CONF_CURRENT_VOLUME_DOSED])
cg.add(parent.set_current_volume_dosed(sens))
if CONF_LAST_VOLUME_REQUESTED in config:
sens = await sensor.new_sensor(config[CONF_LAST_VOLUME_REQUESTED])
cg.add(parent.set_last_volume_requested(sens))
if CONF_TOTAL_VOLUME_DOSED in config:
sens = await sensor.new_sensor(config[CONF_TOTAL_VOLUME_DOSED])
cg.add(parent.set_total_volume_dosed(sens))
if CONF_ABSOLUTE_TOTAL_VOLUME_DOSED in config:
sens = await sensor.new_sensor(config[CONF_ABSOLUTE_TOTAL_VOLUME_DOSED])
cg.add(parent.set_absolute_total_volume_dosed(sens))
if CONF_PUMP_VOLTAGE in config:
sens = await sensor.new_sensor(config[CONF_PUMP_VOLTAGE])
cg.add(parent.set_pump_voltage(sens))
if CONF_MAX_FLOW_RATE in config:
sens = await sensor.new_sensor(config[CONF_MAX_FLOW_RATE])
cg.add(parent.set_max_flow_rate(sens))