esphome:
name: test5
platform: ESP32
board: nodemcu-32s
build_path: build/test5
project:
name: esphome.test5_project
version: "1.0.0"
wifi:
networks:
- ssid: 'MySSID'
password: 'password1'
api:
ota:
logger:
uart:
tx_pin: 1
rx_pin: 3
baud_rate: 9600
modbus:
binary_sensor:
- platform: gpio
pin: GPIO0
id: io0_button
output:
- platform: gpio
pin: GPIO2
id: built_in_led
esp32_ble:
esp32_ble_server:
manufacturer: "ESPHome"
model: "Test5"
esp32_improv:
authorizer: io0_button
authorized_duration: 1min
status_indicator: built_in_led
number:
- platform: template
name: My template number
id: template_number_id
optimistic: true
on_value:
- logger.log:
format: "Number changed to %f"
args: ["x"]
set_action:
- logger.log:
format: "Template Number set to %f"
args: ["x"]
max_value: 100
min_value: 0
step: 5
sensor:
- platform: selec_meter
total_active_energy:
name: "SelecEM2M Total Active Energy"
import_active_energy:
name: "SelecEM2M Import Active Energy"
export_active_energy:
name: "SelecEM2M Export Active Energy"
total_reactive_energy:
name: "SelecEM2M Total Reactive Energy"
import_reactive_energy:
name: "SelecEM2M Import Reactive Energy"
export_reactive_energy:
name: "SelecEM2M Export Reactive Energy"
apparent_energy:
name: "SelecEM2M Apparent Energy"
active_power:
name: "SelecEM2M Active Power"
reactive_power:
name: "SelecEM2M Reactive Power"
apparent_power:
name: "SelecEM2M Apparent Power"
voltage:
name: "SelecEM2M Voltage"
current:
name: "SelecEM2M Current"
power_factor:
name: "SelecEM2M Power Factor"
frequency:
name: "SelecEM2M Frequency"
maximum_demand_active_power:
name: "SelecEM2M Maximum Demand Active Power"
maximum_demand_reactive_power:
name: "SelecEM2M Maximum Demand Reactive Power"
maximum_demand_apparent_power:
name: "SelecEM2M Maximum Demand Apparent Power"