esphome:
name: test5
build_path: build/test5
project:
name: esphome.test5_project
version: "1.0.0"
esp32:
board: nodemcu-32s
framework:
type: esp-idf
advanced:
ignore_efuse_mac_crc: true
wifi:
networks:
- ssid: "MySSID"
password: "password1"
manual_ip:
static_ip: 192.168.1.23
gateway: 192.168.1.1
subnet: 255.255.255.0
api:
ota:
logger:
uart:
- id: uart1
tx_pin: 1
rx_pin: 3
baud_rate: 9600
- id: uart2
tx_pin: 17
rx_pin: 16
baud_rate: 19200
i2c:
modbus:
uart_id: uart1
flow_control_pin: 5
id: mod_bus1
modbus_controller:
- id: modbus_controller_test
address: 0x2
modbus_id: mod_bus1
mqtt:
broker: test.mosquitto.org
port: 1883
discovery: true
discovery_prefix: homeassistant
idf_send_async: false
on_message:
topic: testing/sensor/testing_sensor/state
qos: 0
then:
- lambda: |-
ESP_LOGD("Mqtt Test","testing/sensor/testing_sensor/state=[%s]",x.c_str());
binary_sensor:
- platform: gpio
pin: GPIO0
id: io0_button
icon: mdi:gesture-tap-button
- platform: modbus_controller
modbus_controller_id: modbus_controller_test
id: modbus_binsensortest
register_type: read
address: 0x3200
bitmask: 0x80 #(bit 8)
lambda: !lambda "{ return x ;}"
tlc5947:
data_pin: GPIO12
clock_pin: GPIO14
lat_pin: GPIO15
output:
- platform: gpio
pin: GPIO2
id: built_in_led
- platform: tlc5947
id: output_red
channel: 0
max_power: 0.8
- platform: mcp47a1
id: output_mcp47a1
- platform: modbus_controller
modbus_controller_id: modbus_controller_test
id: modbus_output_test
lambda: |-
return x * 1.0 ;
address: 0x9001
value_type: U_WORD
demo:
esp32_ble:
esp32_ble_server:
manufacturer: "ESPHome"
model: "Test5"
esp32_improv:
authorizer: io0_button
authorized_duration: 1min
status_indicator: built_in_led
number:
- platform: template
name: My template number
id: template_number_id
optimistic: true
max_value: 100
min_value: 0
step: 5
unit_of_measurement: "%"
mode: slider
on_value:
- logger.log:
format: "Number changed to %f"
args: ["x"]
set_action:
- logger.log:
format: "Template Number set to %f"
args: ["x"]
- number.set:
id: template_number_id
value: 50
- number.to_min: template_number_id
- number.to_min:
id: template_number_id
- number.to_max: template_number_id
- number.to_max:
id: template_number_id
- number.increment: template_number_id
- number.increment:
id: template_number_id
cycle: false
- number.decrement: template_number_id
- number.decrement:
id: template_number_id
cycle: false
- number.operation:
id: template_number_id
operation: Increment
cycle: false
- number.operation:
id: template_number_id
operation: !lambda "return NUMBER_OP_INCREMENT;"
cycle: !lambda "return false;"
- id: modbus_numbertest
platform: modbus_controller
modbus_controller_id: modbus_controller_test
name: "ModbusNumber"
address: 0x9002
value_type: U_WORD
lambda: "return x * 1.0; "
write_lambda: |-
return x * 1.0 ;
multiply: 1.0
select:
- platform: template
name: My template select
id: template_select_id
optimistic: true
initial_option: two
restore_value: true
on_value:
- logger.log:
format: "Select changed to %s (index %d)"
args: ["x.c_str()", "i"]
set_action:
- logger.log:
format: "Template Select set to %s"
args: ["x.c_str()"]
- select.set:
id: template_select_id
option: two
- select.first: template_select_id
- select.last:
id: template_select_id
- select.previous: template_select_id
- select.next:
id: template_select_id
cycle: false
- select.operation:
id: template_select_id
operation: Previous
cycle: false
- select.operation:
id: template_select_id
operation: !lambda "return SELECT_OP_PREVIOUS;"
cycle: !lambda "return true;"
- select.set_index:
id: template_select_id
index: 1
- select.set_index:
id: template_select_id
index: !lambda "return 1 + 1;"
options:
- one
- two
- three
- platform: modbus_controller
name: "Modbus Select Register 1000"
address: 1000
value_type: U_WORD
optionsmap:
"Zero": 0
"One": 1
"Two": 2
"Three": 3
sensor:
- platform: selec_meter
total_active_energy:
name: "SelecEM2M Total Active Energy"
import_active_energy:
name: "SelecEM2M Import Active Energy"
export_active_energy:
name: "SelecEM2M Export Active Energy"
total_reactive_energy:
name: "SelecEM2M Total Reactive Energy"
import_reactive_energy:
name: "SelecEM2M Import Reactive Energy"
export_reactive_energy:
name: "SelecEM2M Export Reactive Energy"
apparent_energy:
name: "SelecEM2M Apparent Energy"
active_power:
name: "SelecEM2M Active Power"
reactive_power:
name: "SelecEM2M Reactive Power"
apparent_power:
name: "SelecEM2M Apparent Power"
voltage:
name: "SelecEM2M Voltage"
current:
name: "SelecEM2M Current"
power_factor:
name: "SelecEM2M Power Factor"
frequency:
name: "SelecEM2M Frequency"
maximum_demand_active_power:
name: "SelecEM2M Maximum Demand Active Power"
disabled_by_default: true
maximum_demand_reactive_power:
name: "SelecEM2M Maximum Demand Reactive Power"
disabled_by_default: true
maximum_demand_apparent_power:
name: "SelecEM2M Maximum Demand Apparent Power"
disabled_by_default: true
- id: modbus_sensortest
platform: modbus_controller
modbus_controller_id: modbus_controller_test
address: 0x331A
register_type: read
value_type: U_WORD
- platform: t6615
uart_id: uart2
co2:
name: CO2 Sensor
- platform: bmp3xx
temperature:
name: "BMP Temperature"
oversampling: 16x
pressure:
name: "BMP Pressure"
address: 0x77
iir_filter: 2X
script:
- id: automation_test
then:
- repeat:
count: 5
then:
- logger.log: "looping!"
switch:
- platform: modbus_controller
modbus_controller_id: modbus_controller_test
id: modbus_switch_test
register_type: coil
address: 2
bitmask: 1