mirror of
https://github.com/esphome/esphome.git
synced 2024-12-02 11:44:13 +01:00
82 lines
2.6 KiB
Python
82 lines
2.6 KiB
Python
import esphome.codegen as cg
|
|
import esphome.config_validation as cv
|
|
from esphome.components import sensor, ble_client
|
|
|
|
from esphome.const import (
|
|
DEVICE_CLASS_HUMIDITY,
|
|
DEVICE_CLASS_TEMPERATURE,
|
|
DEVICE_CLASS_PRESSURE,
|
|
STATE_CLASS_MEASUREMENT,
|
|
UNIT_PERCENT,
|
|
UNIT_CELSIUS,
|
|
UNIT_HECTOPASCAL,
|
|
CONF_ID,
|
|
CONF_HUMIDITY,
|
|
CONF_TVOC,
|
|
CONF_PRESSURE,
|
|
CONF_TEMPERATURE,
|
|
UNIT_PARTS_PER_BILLION,
|
|
ICON_RADIATOR,
|
|
)
|
|
|
|
DEPENDENCIES = ["ble_client"]
|
|
|
|
airthings_wave_mini_ns = cg.esphome_ns.namespace("airthings_wave_mini")
|
|
AirthingsWaveMini = airthings_wave_mini_ns.class_(
|
|
"AirthingsWaveMini", cg.PollingComponent, ble_client.BLEClientNode
|
|
)
|
|
|
|
|
|
CONFIG_SCHEMA = cv.All(
|
|
cv.Schema(
|
|
{
|
|
cv.GenerateID(): cv.declare_id(AirthingsWaveMini),
|
|
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_PERCENT,
|
|
device_class=DEVICE_CLASS_HUMIDITY,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
accuracy_decimals=2,
|
|
),
|
|
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_HECTOPASCAL,
|
|
accuracy_decimals=2,
|
|
device_class=DEVICE_CLASS_PRESSURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_TVOC): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_PARTS_PER_BILLION,
|
|
icon=ICON_RADIATOR,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
}
|
|
)
|
|
.extend(cv.polling_component_schema("5min"))
|
|
.extend(ble_client.BLE_CLIENT_SCHEMA),
|
|
)
|
|
|
|
|
|
async def to_code(config):
|
|
var = cg.new_Pvariable(config[CONF_ID])
|
|
await cg.register_component(var, config)
|
|
|
|
await ble_client.register_ble_node(var, config)
|
|
|
|
if CONF_HUMIDITY in config:
|
|
sens = await sensor.new_sensor(config[CONF_HUMIDITY])
|
|
cg.add(var.set_humidity(sens))
|
|
if CONF_TEMPERATURE in config:
|
|
sens = await sensor.new_sensor(config[CONF_TEMPERATURE])
|
|
cg.add(var.set_temperature(sens))
|
|
if CONF_PRESSURE in config:
|
|
sens = await sensor.new_sensor(config[CONF_PRESSURE])
|
|
cg.add(var.set_pressure(sens))
|
|
if CONF_TVOC in config:
|
|
sens = await sensor.new_sensor(config[CONF_TVOC])
|
|
cg.add(var.set_tvoc(sens))
|