mirror of
https://github.com/esphome/esphome.git
synced 2024-12-02 19:54:14 +01:00
5c65f9f9ad
Co-authored-by: Jesse Hills <3060199+jesserockz@users.noreply.github.com>
126 lines
3.9 KiB
Python
126 lines
3.9 KiB
Python
import esphome.codegen as cg
|
|
import esphome.config_validation as cv
|
|
from esphome.components import sensor
|
|
from esphome.const import (
|
|
CONF_GAS_RESISTANCE,
|
|
CONF_HUMIDITY,
|
|
CONF_PRESSURE,
|
|
CONF_TEMPERATURE,
|
|
DEVICE_CLASS_HUMIDITY,
|
|
DEVICE_CLASS_PRESSURE,
|
|
DEVICE_CLASS_TEMPERATURE,
|
|
STATE_CLASS_MEASUREMENT,
|
|
UNIT_CELSIUS,
|
|
UNIT_HECTOPASCAL,
|
|
UNIT_OHM,
|
|
UNIT_PARTS_PER_MILLION,
|
|
UNIT_PERCENT,
|
|
ICON_GAS_CYLINDER,
|
|
ICON_GAUGE,
|
|
ICON_THERMOMETER,
|
|
ICON_WATER_PERCENT,
|
|
)
|
|
from . import (
|
|
BME680BSECComponent,
|
|
CONF_BME680_BSEC_ID,
|
|
CONF_SAMPLE_RATE,
|
|
SAMPLE_RATE_OPTIONS,
|
|
)
|
|
|
|
DEPENDENCIES = ["bme680_bsec"]
|
|
|
|
CONF_IAQ = "iaq"
|
|
CONF_IAQ_ACCURACY = "iaq_accuracy"
|
|
CONF_CO2_EQUIVALENT = "co2_equivalent"
|
|
CONF_BREATH_VOC_EQUIVALENT = "breath_voc_equivalent"
|
|
UNIT_IAQ = "IAQ"
|
|
ICON_ACCURACY = "mdi:checkbox-marked-circle-outline"
|
|
ICON_TEST_TUBE = "mdi:test-tube"
|
|
|
|
TYPES = [
|
|
CONF_TEMPERATURE,
|
|
CONF_PRESSURE,
|
|
CONF_HUMIDITY,
|
|
CONF_GAS_RESISTANCE,
|
|
CONF_IAQ,
|
|
CONF_IAQ_ACCURACY,
|
|
CONF_CO2_EQUIVALENT,
|
|
CONF_BREATH_VOC_EQUIVALENT,
|
|
]
|
|
|
|
CONFIG_SCHEMA = cv.Schema(
|
|
{
|
|
cv.GenerateID(CONF_BME680_BSEC_ID): cv.use_id(BME680BSECComponent),
|
|
cv.Optional(CONF_TEMPERATURE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_CELSIUS,
|
|
icon=ICON_THERMOMETER,
|
|
accuracy_decimals=1,
|
|
device_class=DEVICE_CLASS_TEMPERATURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
).extend(
|
|
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
|
|
),
|
|
cv.Optional(CONF_PRESSURE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_HECTOPASCAL,
|
|
icon=ICON_GAUGE,
|
|
accuracy_decimals=1,
|
|
device_class=DEVICE_CLASS_PRESSURE,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
).extend(
|
|
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
|
|
),
|
|
cv.Optional(CONF_HUMIDITY): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_PERCENT,
|
|
icon=ICON_WATER_PERCENT,
|
|
accuracy_decimals=1,
|
|
device_class=DEVICE_CLASS_HUMIDITY,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
).extend(
|
|
{cv.Optional(CONF_SAMPLE_RATE): cv.enum(SAMPLE_RATE_OPTIONS, upper=True)}
|
|
),
|
|
cv.Optional(CONF_GAS_RESISTANCE): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_OHM,
|
|
icon=ICON_GAS_CYLINDER,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_IAQ): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_IAQ,
|
|
icon=ICON_GAUGE,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_IAQ_ACCURACY): sensor.sensor_schema(
|
|
icon=ICON_ACCURACY,
|
|
accuracy_decimals=0,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_CO2_EQUIVALENT): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_PARTS_PER_MILLION,
|
|
icon=ICON_TEST_TUBE,
|
|
accuracy_decimals=1,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
cv.Optional(CONF_BREATH_VOC_EQUIVALENT): sensor.sensor_schema(
|
|
unit_of_measurement=UNIT_PARTS_PER_MILLION,
|
|
icon=ICON_TEST_TUBE,
|
|
accuracy_decimals=1,
|
|
state_class=STATE_CLASS_MEASUREMENT,
|
|
),
|
|
}
|
|
)
|
|
|
|
|
|
async def setup_conf(config, key, hub):
|
|
if key in config:
|
|
conf = config[key]
|
|
sens = await sensor.new_sensor(conf)
|
|
cg.add(getattr(hub, f"set_{key}_sensor")(sens))
|
|
if CONF_SAMPLE_RATE in conf:
|
|
cg.add(getattr(hub, f"set_{key}_sample_rate")(conf[CONF_SAMPLE_RATE]))
|
|
|
|
|
|
async def to_code(config):
|
|
hub = await cg.get_variable(config[CONF_BME680_BSEC_ID])
|
|
for key in TYPES:
|
|
await setup_conf(config, key, hub)
|